Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Roof Beams

Combustible Dusts Dusts are particularly hazardous they have a very high surface area-to-volume ratio. When finely divided as powders or (dusts, solids burn quite differently from the original material in the bulk. Dust and fiber deposits can spread fire across a room or along a ledge or roof beam very quickly. On the other hand, accumulations of dust can smolder slowly for long periods, giving little indication that combustion has started until the fire suddenly flares up, possibly when no one suspects a problem. [Pg.2314]

The roof is a siab spanning between roof beams. For the design of the roof, a section 1 foot wide by 8 feet long will be used,... [Pg.21]

The roof girders are simply supported at both ends with loads from roof beams applied at quarter points. [Pg.91]

Load calculations braced frames 12-39—12-43 columns 11-37—11-40 exterior walls 11 4—11-10 foundations 11-41—11 45, 12-43—12-46 rigid frames 12-31 — 1 2-39 roof beams 1 1-27—1 1-31 roof decking 12-6—12-71 roof girders 1 1-36 roof putins 1 2-16—1 2-26 roof slabs, in-plane 1 1-1 1 — 1 1-16 roof slabs, out-ofplane 1 1-21—1 1-26 side walls, in-plane 11-16—11-20 wall girts 12-26—12-30 wall panels 12-12-12-16... [Pg.135]

A series of separate SDOF dynamic analyses are performed for each of the primary structural components. For example, a typical roof system consists of a roof slab supported on structural steel roof beams which are in turn supported by roof girders. Separate SDOF dynamic analyses are performed for the slab, beams and girders using the reaction time history of the supported member as loading input 10... [Pg.174]

Many roof beams, roof purlins and wall girts in existing petrochemical structures are not capable of developing their full plastic moment capacity for loads in the plane... [Pg.204]

Cut hote in masonry wall and anchorto existing roof beam. [Pg.208]

Each interior roof beam supports a roof slab width of 8 feet (244 cm). [Pg.222]

The roof beam is connected to the roof slab to prevent separation during rebound. In this case, the connection is to be designed to prevent composite action between the roof slab and the roof beam. Because composite action greatly increases the bending capacity while not increasing the beam s shear capacity, neglecting this effect could be very unconservative. [Pg.222]

Front wails are 30 ft by 10 ft (9.1 m by 3.0 m) between supports, a 3 to 1 ratio. Therefore the front wall will be analyzed as a one way simply supported beam, spanning vertically between the grade beam and the roof beam. [Pg.254]

We sometimes have problems fitting a new window into an old roof because the size of the window and the rafter of the roof beams do not fit. [Pg.50]

The window is available in sizes for all roof-beam rafters. [Pg.52]

End OF ROOF beam rig. 8,8 Joint detail at Camden School. [Pg.321]

Bate, S.C.C., Report on the failure of roof beams at Sir John Cass s... [Pg.365]

Install roof beams over the entire hole. [Pg.269]

Paul is adamant that the method cannot involve hot-rolled steel elements and encourages Adam to focus on an alternative based on horizontal roof beams with vertical droppers on their ends, Adam counters with the following problems ... [Pg.215]


See other pages where Roof Beams is mentioned: [Pg.43]    [Pg.70]    [Pg.76]    [Pg.91]    [Pg.91]    [Pg.126]    [Pg.205]    [Pg.222]    [Pg.226]    [Pg.51]    [Pg.58]    [Pg.58]    [Pg.214]    [Pg.100]    [Pg.986]    [Pg.135]    [Pg.309]    [Pg.312]    [Pg.546]    [Pg.379]    [Pg.219]    [Pg.251]    [Pg.9279]    [Pg.312]    [Pg.103]    [Pg.360]   


SEARCH



Roofing

Roofs

© 2024 chempedia.info