Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Roller apparatus

Figure 11.7 Scanning electron micrograph of pentacene fibers prepared by dewetting of a hot trichlorobenzene solution using the roller apparatus. The fibers are aligned along the rolling direction (reprinted with permission from Ref 71). The scale bar is 5 pm. Figure 11.7 Scanning electron micrograph of pentacene fibers prepared by dewetting of a hot trichlorobenzene solution using the roller apparatus. The fibers are aligned along the rolling direction (reprinted with permission from Ref 71). The scale bar is 5 pm.
The Wheaton roller apparatus comes in modular form. The base unit holds the drive and will roll 5 bottles. Up to 8 additional decks can be added to allow rotation of up to 45 bottles. Also available is an alarm system which gives warning of rotational failure, and an auxiliary battery system which will enable the apparatus to operate for up to 48 h in the absence of an electricity supply. [Pg.42]

After characterizing the basic shear properties of the Inks, their cure behavior was Investigated by placing samples on a specially designed 2 roller apparatus where one of the rolls was heated to 80 C (roughly equivalent to the press temperature). [Pg.152]

Curing Study. Although the data on the mechanical properties of the uncured inks provide information that is useful in fabricating the inks, no explanation for the poor performance of BK-62 was found. As a result, experiments aimed at examining the cure behavior of the inks were conducted. Samples of the inks were cured on a heated 2 roller apparatus, and, after various curing times, small portions of ink were removed and characterized for oscillatory and short term steady flow viscosity. In view of the complexity of the oscillatory behavior, most of the emphasis is on the steady flow tests however, it is useful to examine the general trends exhibited in the oscillatory data. [Pg.159]

A confluent flask should be washed twice in sterile PBS and the cells trypsinized in 10 ml of trypsin/EDTA solution. Transfer the cells into the roller bottle at a density of 1.5 x lO /cm and in a final volume of 400 ml complete medium. Charge the bottle with sterile filtered 5% C02/95% air and place at 37°C on a roller apparatus at a rotation speed of 0.5 rpm. After 2 days the bottle should be confluent. At this point replace the medium with 200 ml complete medium containing 2 vciM thymidine and incubate for a further 11 hr in order to accumulate cells in S phase. This 11-hr thymidine block is most conveniently carried out overnight. [Pg.359]

On completion of the thymidine block wash the monolayer of cells once with 50 ml complete medium and then return the bottle to the roller apparatus with 150 ml fresh complete medium equilibrated with CO2. After 4 hr add nocodazole to a final concentration of 600 ng/ml. The nocodazole may be stored at -20°C... [Pg.359]

We now come to the final stages of morphology development (for disperse systems). Deformation and breakup of liquid droplets in a liquid matrix was first studied in series of articles by G.I. Taylor [40, 41] in 1932. Taylor first modeled the viscosity of emulsions and in a second article studied the deformation and breakup of liquid droplets. The basis of the work ofTaylor is again the concept of the interfacial tension between immiscible liquid phases (Section 6.3.2.1). Taylor [41] subsequently described experiments with paraUel-band (for shear flow) and four roller apparatus for extensional flow using individual droplets based upon combinations of... [Pg.276]

In the second case a 0.75 kW motor with a pre-set springloaded tension apparatus is installed. The stainless steel wire (6) is wound 4-5 times around a drum. When the motor is switched on, the wire tightens and the filter net (3) is drawn backwards and forwards over the front roller (4). [Pg.235]

Fig 7. Design of apparatus and connection of the pickup to the oscillograph 1-rollers 2-sleeve 3-bedplate 4-transducer 5-charge... [Pg.313]

Hot melt adhesive compositions are used among others to bond edgebands. During edgebanding, the hot melt adhesive is maintained in the molten state in the glue pot of the edgebanding apparatus for extended periods of time. Fillers are added to hot melt adhesive compositions in order to decrease the costs of the adhesive composition and to improve the break action, such that it provides a clean break from the roller during the application procedure (25). [Pg.202]

It is not possible to remove the cells mechanically unless a way can be developed to dismantle the apparatus using a hot wire. Moreover, the factory is very expensive and can be used once only. However, it produces extremely high cell yields using very little space and in contrast to roller cultures requires no machinery which itself is expensive and liable to break down at critical times. As it is... [Pg.44]

Various other procedures have been devised to increase the surface area within a vessel upon which cells may grow. The problem is always to maintain an adequate supply of nutrients including oxygen and to remove waste products, particularly acid. The New Brunswick Scientific Co. (Appendix 3) produces a piece of apparatus which continuously perfuses roller bottles by means of a rotating cap through which the various feed tubes pass. [Pg.45]


See other pages where Roller apparatus is mentioned: [Pg.197]    [Pg.81]    [Pg.324]    [Pg.277]    [Pg.278]    [Pg.145]    [Pg.946]    [Pg.322]    [Pg.197]    [Pg.81]    [Pg.324]    [Pg.277]    [Pg.278]    [Pg.145]    [Pg.946]    [Pg.322]    [Pg.2229]    [Pg.453]    [Pg.19]    [Pg.440]    [Pg.768]    [Pg.38]    [Pg.422]    [Pg.424]    [Pg.430]    [Pg.193]    [Pg.432]    [Pg.73]    [Pg.82]    [Pg.99]    [Pg.174]    [Pg.346]    [Pg.358]    [Pg.366]    [Pg.481]    [Pg.521]    [Pg.609]    [Pg.645]    [Pg.652]    [Pg.662]    [Pg.957]    [Pg.957]    [Pg.958]    [Pg.987]    [Pg.145]    [Pg.246]   
See also in sourсe #XX -- [ Pg.42 ]




SEARCH



Rollers

© 2024 chempedia.info