Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Signal intensities, relative

E/Z ratios were determined from relative signal intensities in the F NMR spectrum. [Pg.596]

In a study with 3 EMS patients the relative signal intensities in proton spectra recorded at an echo time of 50 ms with a repetition time of 2 s were quantitatively compared with healthy controls. It was evident that the muscle specific signals from TMA and Cr are relatively low in EMS patients (TMA 0.20-0.43% in the patients and 0.47-0.68% in the controls creatine 0.32-0.60% in the patients and 0.48-0.77% in the controls) probably indicating changes of concentrations and altered chemical surroundings of TMA and Cr in the myoplasm of the diseased cells. The overall lipid signal was found to be... [Pg.61]

It is not usually possible to integrate routine C spectra directly unless specific precautions have been taken. However with proper controls, NMR spectroscopy can be used quantitatively and it is a valuable technique for the analysis of mixtures. To record C NMR spectra where the relative signal intensity can be reliably determined, the spectra must be recorded with techniques to suppress the Nuclear Overhauser Effect and with a long delay between the acquisition of successive spectra to ensure that all of the carbons in the molecule are completely relaxed between spectral acquisitions. [Pg.66]

B. "Relative" Signal Intensities (Short Data Collection Times)... [Pg.252]

The use of MALDI-MS for the measurement of low molecular mass compounds is widely accepted now [61], but quantification remains problematic. The main problem is the inhomogeneous distribution of the analytes within the matrix [62]. This leads to different amounts of ions and therefore to different signal intensities at various locations of a sample spot. The simplest and most effective way to overcome this problem is the use of an appropriate internal standard [63]. The use of deuterated compounds with a high molecular similarity to the analyte as internal standards leads to a linear correlation between relative signal intensities and relative amount of the compound to be quantified (Fig. 4b) [64]. Using this approach it is possible to quantitate substrates and products of enzyme catalyzed reactions. Two examples were shown recently by Kang and coworkers [64, 65]. The first was a lipase catalyzed reaction which produces 2-methoxy-N-[(lR)-l-phenylethyl]-acetamide (MET) using rac-a-... [Pg.14]

Fig. 4. a rac-Phenylethylamine (PEA) and 2-methoxy-J T-[(li )-l-phenylethyl]-acetamide (MET) are substrate and product in a lipase catalyzed transesterification, b Linear relationship between relative signal intensities in MALDI-MS and the relative concentrations of PEA/d5-labeled PEA. c Comparison of decrease in PEA during enzymatic conversion as measured by quantitative MALDI-MS and gas chromatography (GC)... [Pg.16]

A mutarotational equilibration is demonstrated in Fig. 5.5 by the time dependent 13C NMR spectrum of a solution of D-glucose. Initially, the solution contains almost pure a-D-glucose, but the signals at lower field corresponding to the /i-anomer soon appear. At equilibirium, the relative signal intensities indicate that the /i-anomer is favored (60% P, 40% a Fig. 5.5) [685],... [Pg.380]

Sample preparation method Relative signal intensity ... [Pg.169]

Draw formulae for all the isomers of dichloro cyclopropane and predict the relative signal intensities in their H NMR spectra. Compare your answer with results obtained from a determination of the symmetry elements and point groups. [Pg.43]

The two diastereomers of 1,3,5-trichlorocyclohexane have relative signal intensities of 1 1 1 and 2 2 2 1 1 1 in their lU NMR spectra, respectively. Which set of signals corresponds to which isomer ... [Pg.50]

Assignments of intensity are made for elements with multiple isotopes in a prioritized order that depends on the relative signal intensities observed. The assignments are evaluated and adjusted if necessary for elements with overlapping isotopes. [Pg.123]

Kovarsky et al have used the SIMS method to determine the mole fraction in InGaN [8], Their technique is based on a comparison of the relative signal intensities of CsM+ (M = In, Ga) and does not require reference samples. The SIMS results were independently confirmed by XRD, energy dispersive X-ray fluorescence spectroscopy, EPMA and SNMS, and the absolute value of the InN mole fraction has a relative accuracy <15%. [Pg.341]

The signals for carbons 5 (of which there are two) and 6 (of which there is one) are so close that assignments based on calculated chemical shifts alone are not likely to be 100% reliable. But notice that relative signal intensity is also consistent with the above assignment. [Pg.96]


See other pages where Signal intensities, relative is mentioned: [Pg.1570]    [Pg.442]    [Pg.53]    [Pg.114]    [Pg.134]    [Pg.300]    [Pg.119]    [Pg.239]    [Pg.113]    [Pg.252]    [Pg.263]    [Pg.279]    [Pg.89]    [Pg.621]    [Pg.90]    [Pg.1404]    [Pg.180]    [Pg.58]    [Pg.302]    [Pg.249]    [Pg.200]    [Pg.404]    [Pg.264]    [Pg.265]    [Pg.124]    [Pg.149]    [Pg.867]    [Pg.31]    [Pg.204]    [Pg.211]    [Pg.16]    [Pg.359]    [Pg.293]    [Pg.293]    [Pg.296]   
See also in sourсe #XX -- [ Pg.252 ]




SEARCH



Intensity relative

Intensive signals

Signal intensity

© 2024 chempedia.info