Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Reference positioning

If the reference time f and the current time t coincide then the reference and current positions will also coincide and the right-hand side of Equation (3.77) can be replaced by the reference position defined as x in Equation (3.76). In a velocity field given as = u x,t ) the motion of a material point can be described... [Pg.104]

COU NTjiEF is the reference position of the carriage at the start of each pass. [Pg.550]

Misdiagnosis arises when undue emphasis is placed on symptoms such as ideas of reference Positive symptoms may occur and the onset is often rapid with relatively good premorbid functioning Distinctions such as mood congruency can be difficult to apply Negative symptoms may occur in depression... [Pg.548]

Variational transition-state theory (VTST), as its name implies, variationally moves the reference position along the MEP that is employed for the computation of the activated complex free energy, either backwards or forwards from the TS sttuctme, until the rate constant is minimized. Notationally... [Pg.531]

Tor reference. Positive identification can be made only by collecting the compound or transierring it as it elutes directly into another apparatus for analysis by other means, such as infrared or ultraviolet spectroscopy, mass spectrometry, or nuclear magnetic resonance. Commercially available apparatus is available which combines in a single unit both a gas chromatograph and an infrared, ultraviolet, or mass spectrometer for routine separation and identilicalion. The ancillary system may also be microprocessor-based, with an extensive memory for storing libraries of known infrared spectra or fragmentation patterns (in the case of mass spectrometers). Such systems allow microprocessor-controlled comparison and identilicalion of detected compounds. [Pg.378]

Next, the zero-gap reference position (the contact point where the stator and the rotor just touch) should be set using the software routines for bringing rotor and stator into contact. After this, the gap used for the test itself can be set. Generally, the zero-gap referencing procedure should be done at the temperature of interest for testing. Some instruments control temperature using an environmental chamber or oven, whereas others will heat or cool the stator. If the latter is the case, then for temperatures that are well away from ambient, the gap can be referenced at ambient and the temperature of interest set with the sample in place to aid thermal conductivity. This is reasonable if the instrument has a gap temperature compensation factor. Most autogap instruments will have this facility built into the firmware that controls the rotor position with respect to the stator. [Pg.1145]

Smaller values of are obtained for interferometers operated in a double-beam mode, since the moveable mirror must be left stationary for a fraction of the cycle time to allow the detector to stabilize each time the beam is switched from the sample to the reference position. With an optical null grating spectrometer the chopper is used not only to modulate the beam but also to alternate the beam between sample and reference channels. Thus, it takes approximately the same time to measure a transmittance spectrum using a double beam optical null spectrometer as it takes to measure a single-beam spectrum with the same S/R. Hence, for this type of spectrometer may be assigned a value of 2. [Pg.23]

As shown above, rotational entropy reflects differences in the extent to which the solid and liquid molecules can rotate. If the position of the molecule in the solid lattice is designated as a reference position, then it is possible to indicate the number of ways that a molecule in the liquid can be rotated to produce an indistinguishable position. For example, anthracene can be rigidly rotated into four to produce indistinguishable positions ... [Pg.36]

It has been found that a good estimate of oa13. the 13C chemical shift (the displacement of the resonance of a carbon nucleus from a reference position when in the presence of an applied magnetic field) is a function of the electronic environment of the atom and can be correlated with its charge density. [Pg.74]

Streitwieser40 pointed out that the correlation which exists between relative rates of reaction in deuterodeprotonation, nitration, and chlorination, and equilibrium constants for protonation in hydrofluoric acid amongst polynuclear hydrocarbons (cf. 6.2.3) constitutes a relationship of the Hammett type. The standard reaction is here the protonation equilibrium (for which p is unity by definition). For convenience he selected the 1 -position of naphthalene, rather than a position in benzene as the reference position (for which er is zero by definition), and by this means was able to evaluate p -values for the substitutions mentioned, and cr -values for positions in a number of hydrocarbons. The p -values (for protonation equilibria, x for deuterodeprotonation, 0-47 for nitration, 0-26 and for chlorination, 0-64) are taken to indicate how closely the transition states of these reactions resemble a er-complex. [Pg.138]

Following the idea of superimposed continua, each constituent follows its individual motion xa (Xa, t) and has its own velocity field with respect to different reference positions XQ ... [Pg.71]

The negative peak in the baseline at 4520 cm-1 proved to be a convenient reference position. Its origin is presently unknown, but it likely arises from slight differences between the silica DIT cell used for the sample and that used for the carbon tetrachloride reference. Band integration did not work veil for quantitation in this study, probably because of uncertainties in the data above 5264 cm-1 where the discontinuity due to the electronic filter in the spectrometer occurs. [Pg.81]

We now identify the arbitrary coordinate value x0 with some reference position in or near the zone, usually at the center of the zone or at the boundary of the wall or physical barrier confining the zone. We then define a coordinate system specifically fixed to the zone analogous to that of Eq. 3.36... [Pg.114]

Reference and sample measurements are performed consecutively, and the resultant (sample) spectrum is obtained as the ratio of the two photon fluxes onto the detector. In a single-beam spectrometer, there are no other options in a double-beam spectrometer, the photon fluxes of the sample and reference beam path are compared. When an integrating sphere is used with two ports and a white standard in the reference position, the photon fluxes are comparable to each other, and no problems occur. Note that the ports are part of the sphere and that any material change in the reference or sample position will change the average sphere reflectance pave. The reference measurement should be conducted with exactly the same components (windows) as the sample measurement otherwise, "substitution errors" may occur. [Pg.169]

It is easy to see that the orientation of a vector in space can be described by the two spherical polar angles, 0 and 4>. From a reference position parallel to the Z axis, the required orientation is obtained as follows ... [Pg.146]

Reference position (cm) Potential (mV) Potential gradient (mV/cm) Current density (mA/cm2) Current density (pA/cm2)... [Pg.414]


See other pages where Reference positioning is mentioned: [Pg.138]    [Pg.423]    [Pg.22]    [Pg.956]    [Pg.447]    [Pg.50]    [Pg.4]    [Pg.127]    [Pg.134]    [Pg.73]    [Pg.56]    [Pg.56]    [Pg.77]    [Pg.776]    [Pg.386]    [Pg.150]    [Pg.78]    [Pg.150]    [Pg.341]    [Pg.70]    [Pg.201]    [Pg.161]    [Pg.44]    [Pg.188]    [Pg.104]    [Pg.171]    [Pg.9]    [Pg.325]    [Pg.114]    [Pg.162]    [Pg.163]    [Pg.173]    [Pg.175]   
See also in sourсe #XX -- [ Pg.24 ]




SEARCH



Electrochemistry reference electrode, position

Percentile estimate with respect to a positive reference serum

Position of Reference Electrode

Positional reference system

Positioning the Reference Electrode

Reference Electrodes position

© 2024 chempedia.info