Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Quantitation voltammetry

Quantitative voltammetry has been applied to a wide variety of sample types, including environmental samples, clinical samples, pharmaceutical formulations, steels, gasoline, and oil. [Pg.520]

What Options Are Available for Rigorous, Quantitative Voltammetry ... [Pg.308]

FIGURE 2.15 Schematic illustration of the different ET probability for an electroactive molecule on a large electrode and a spherical nanoelectrode. (Reprinted with permission from Limon-Petersen, J.G., Streeter, L, Rees, N.V., and Compton, R.G., Quantitative voltammetry in weakly supported media Effects of the applied overpotential and supporting electrolyte concentration on the one electron oxidation of ferrocene in acetonitrile, J. Phys. Chem. C, 2009, 113, 333-337. Copyright 2009 American Chemical Society.)... [Pg.48]

In potentiometry, the potential of an electrochemical cell under static conditions is used to determine an analyte s concentration. As seen in the preceding section, potentiometry is an important and frequently used quantitative method of analysis. Dynamic electrochemical methods, such as coulometry, voltammetry, and amper-ometry, in which current passes through the electrochemical cell, also are important analytical techniques. In this section we consider coulometric methods of analysis. Voltammetry and amperometry are covered in Section 1 ID. [Pg.496]

In voltammetry a time-dependent potential is applied to an electrochemical cell, and the current flowing through the cell is measured as a function of that potential. A plot of current as a function of applied potential is called a voltammogram and is the electrochemical equivalent of a spectrum in spectroscopy, providing quantitative and qualitative information about the species involved in the oxidation or reduction reaction.The earliest voltammetric technique to be introduced was polarography, which was developed by Jaroslav Heyrovsky... [Pg.508]

Thus, the limiting current, is a linear function of the concentration of O in bulk solution, and a quantitative analysis is possible using any of the standardization methods discussed in Chapter 5. Equations similar to equation 11.35 can be developed for other forms of voltammetry, in which peak currents are related to the analyte s concentration in bulk solution. [Pg.514]

Stripping Voltammetry One of the most important quantitative voltammetric techniques is stripping voltammetry, which is composed of three related techniques anodic, cathodic, and adsorptive stripping voltammetry. Since anodic strip-... [Pg.516]

This experiment introduces hydrodynamic voltammetry using a rotating working electrode. Its application for the quantitative analysis of K4Fe(CN)6 is demonstrated. [Pg.535]

The technique of hydrodynamic modulation voltammetry (HMV), in which the rate of stirring is pulsed between high and low values, is demonstrated in this experiment. The application of HMV for the quantitative analysis of ascorbic acid in vitamin C tablets using the method of standard additions also is outlined. [Pg.535]

The application of anodic stripping voltammetry for the quantitative analysis of Cd, Pb, and Cu in natural waters is described in this experiment. [Pg.535]

More recent research provides reversible oxidation-reduction potential data (17). These allow the derivation of better stmcture-activity relationships in both photographic sensitization and other systems where electron-transfer sensitizers are important (see Dyes, sensitizing). Data for an extensive series of cyanine dyes are pubflshed, as obtained by second harmonic a-c voltammetry (17). A recent "quantitative stmcture-activity relationship" (QSAR) (34) shows that Brooker deviations for the heterocycHc nuclei (discussed above) can provide estimates of the oxidation potentials within 0.05 V. An oxidation potential plus a dye s absorption energy provide reduction potential estimates. Different regression equations were used for dyes with one-, three-, five-methine carbons in the chromophore. Also noted in Ref. 34 are previous correlations relating Brooker deviations for many heterocycHc nuclei to the piC (for protonation/decolorization) for carbocyanine dyes the piC is thus inversely related to oxidation potential values. [Pg.396]

Cyclic voltammetry can also be useful for quantitative purposes, based on measurements of the peak current (equation 2-1). Such quantitative applications require the establishment of the proper baseline. For neighboring peaks (of a mixture), the baseline for the second peak is obtained by extrapolating the current decay of the... [Pg.39]

Describe clearly the principle and operation of potentiometric stripping analysis (PSA). How it is differed from anodic stripping voltammetry (ASV) What is the quantitative signal What is its advantage over ASV ... [Pg.99]

For the in situ characterization of modified electrodes, the method of choice is electrochemical analysis by cyclic voltammetry, ac voltammetry, chronoamperometry or chronocoulometry, or rotating disk voltametry. Cyclic voltammograms are easy to interpret from a qualitative point of view (Fig, 1). The other methods are less direct but they can yield quantitative data more readily. [Pg.60]

The concentration of the transferred ion in organic solution inside the pore can become much higher than its concentration in the bulk aqueous phase [15]. (This is likely to happen if r <5c d.) In this case, the transferred ion may react with an oppositely charged ion from the supporting electrolyte to form a precipitate that can plug the microhole. This may be one of the reasons why steady-state measurements at the microhole-supported ITIES are typically not very accurate and reproducible [16]. Another problem with microhole voltammetry is that the exact location of the interface within the hole is unknown. The uncertainty of and 4, values affects the reliability of the evaluation of the formal transfer potential from Eq. (5). The latter value is essential for the quantitative analysis of IT kinetics [17]. Because of the above problems no quantitative kinetic measurements employing microhole ITIES have been reported to date and the theory for kinetically controlled CT reactions has yet to be developed. [Pg.383]

The key factor in voltammetry (and polarography) is that the applied potential is varied over the course of the measurement. The voltammogram, which is a current-applied potential curve, / = /( ), corresponds to a voltage scan over a range that induces oxidation or reduction of the analytes. This plot allows identification and measurement of the concentration of each species. Several metals can be determined. The limiting currents in the redox processes can be used for quantitative analysis this is the basis of voltammetric analysis [489]. The methods are based on the direct proportionality between the current and the concentration of the electroactive species, and exploit the ease and precision of measuring electric currents. Voltammetry is suitable for concentrations at or above ppm level. The sensitivity is often much higher than can be obtained with classical titrations. The sensitivity of voltammetric... [Pg.669]

In voltammetry (abbreviation of voltamperometry), a current-potential curve of a suitably chosen electrochemical cell is determined, from which qualitative and/or quantitative analytical data can be obtained. [Pg.114]

Competitive immunoassays may also be used to determine small chemical substances [10, 11]. An electrochemical immunosensor based on a competitive immunoassay for the small molecule estradiol has recently been reported [11]. A schematic diagram of this immunoassay is depicted in Fig. 5.3. In this system, anti-mouse IgG was physisorbed onto the surface of an SPCE. This was used to bind monoclonal mouse anti-estradiol antibody. The antibody coated SPCE was then exposed to a standard solution of estradiol (E2), followed by a solution of AP-labeled estradiol (AP-E2). The E2 and AP-E2 competed for a limited number of antigen binding sites of the immobilized anti-estradiol antibody. Quantitative analysis was based on differential pulse voltammetry of 1-naphthol, which is produced from the enzymatic hydrolysis of the enzyme substrate 1-naphthyl phosphate by AP-E2. The analytical range of this sensor was between 25 and 500pg ml. 1 of E2. [Pg.143]


See other pages where Quantitation voltammetry is mentioned: [Pg.524]    [Pg.524]    [Pg.514]    [Pg.523]    [Pg.525]    [Pg.458]    [Pg.265]    [Pg.299]    [Pg.871]    [Pg.904]    [Pg.82]    [Pg.123]    [Pg.68]    [Pg.539]    [Pg.407]    [Pg.385]    [Pg.707]    [Pg.385]    [Pg.682]    [Pg.670]    [Pg.196]    [Pg.306]    [Pg.74]    [Pg.153]    [Pg.472]    [Pg.473]    [Pg.170]    [Pg.176]    [Pg.248]    [Pg.390]    [Pg.38]    [Pg.485]   
See also in sourсe #XX -- [ Pg.156 ]




SEARCH



Quantitative and Qualitative Aspects of Voltammetry

Quantitative anodic-stripping voltammetry

Voltammetry quantitative

Voltammetry quantitative

Voltammetry quantitative applications using

© 2024 chempedia.info