Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Process spectroscopic methods

The two possible initiations for the free-radical reaction are step lb or the combination of steps la and 2a from Table 1. The role of the initiation step lb in the reaction scheme is an important consideration in minimising the concentration of atomic fluorine (27). As indicated in Table 1, this process is spontaneous at room temperature [AG25 = —24.4 kJ/mol (—5.84 kcal/mol) ] although the enthalpy is slightly positive. The validity of this step has not yet been conclusively estabUshed by spectroscopic methods which makes it an unsolved problem of prime importance. Furthermore, the fact that fluorine reacts at a significant rate with some hydrocarbons in the dark at temperatures below —78° C indicates that step lb is important and may have Httie or no activation energy at RT. At extremely low temperatures (ca 10 K) there is no reaction between gaseous fluorine and CH or 2 6... [Pg.275]

The objective ia any analytical procedure is to determine the composition of the sample (speciation) and the amounts of different species present (quantification). Spectroscopic techniques can both identify and quantify ia a single measurement. A wide range of compounds can be detected with high specificity, even ia multicomponent mixtures. Many spectroscopic methods are noninvasive, involving no sample collection, pretreatment, or contamination (see Nondestructive evaluation). Because only optical access to the sample is needed, instmments can be remotely situated for environmental and process monitoring (see Analytical METHODS Process control). Spectroscopy provides rapid real-time results, and is easily adaptable to continuous long-term monitoring. Spectra also carry information on sample conditions such as temperature and pressure. [Pg.310]

Analysis of substances (this is a key process in the identification of new or known chemical and biological substances. Methods of analysis include spectroscopic methods, derivatisation and sequencing meth s). [Pg.72]

RAIRS is a non-destructive infrared technique with special versatility - it does not require the vacuum conditions essential for electron spectroscopic methods and is, therefore, in principle, applicable to the study of growth processes [4.270]. By use of a polarization modulation technique surfaces in a gas phase can be investigated. Higher surface sensitivity is achieved by modulation of the polarization between s and p. This method can also be used to discriminate between anisotropic near-sur-face absorption and isotropic absorption in the gas phase [4.271]. [Pg.250]

One of the most important and exciting advances in modern biochemistry has been the application of spectroscopic methods, which measure the absorption and emission of energy of different frequencies by molecules and atoms. Spectroscopic studies of proteins, nucleic acids, and other biomolecules are providing many new insights into the structure and dynamic processes in these molecules. [Pg.99]

Real-time spectroscopic methods can be used to measure the binding, dissociation, and internalization of fluorescent ligands with cell-surface receptors on cells and membranes. The time resolution available in these methods is sufficient to permit a detailed analysis of complex processes involved in cell activation, particularly receptor-G protein dynamics. A description of the kinetics and thermodynamics of these processes will contribute to our understanding of the basis of stimulus potency and efficacy. [Pg.65]

This study Illustrates the use of situ MBS as applied to the Investigation of species Involved In redox processes In porous electrodes. It Is expected that a systematic utilization of this technique may enable the acquisition of microscopic level Information of difficult accessibility with other spectroscopic methods, although limited to only Mossbauer active nucleus. [Pg.545]

The set of possible dependent properties and independent predictor variables, i.e. the number of possible applications of predictive modelling, is virtually boundless. A major application is in analytical chemistry, specifically the development and application of quantitative predictive calibration models, e.g. for the simultaneous determination of the concentrations of various analytes in a multi-component mixture where one may choose from a large arsenal of spectroscopic methods (e.g. UV, IR, NIR, XRF, NMR). The emerging field of process analysis,... [Pg.349]

In polymer/additive deformulation (of extracts, solutions and in-polymer), spectroscopic methods (nowadays mainly UV, IR and to a lesser extent NMR followed at a large distance by Raman) play an important role, and even more so in process analysis, where the time-consuming chromatographic techniques are less favoured. Some methods, as NMR and Raman spectrometry, were once relatively insensitive, but seem poised to become better performing. Quantitative polymer/additive analysis may benefit from more extensive use of 600-800 MHz 1-NMR equipped with a high-temperature accessory (soluble additives only). [Pg.734]


See other pages where Process spectroscopic methods is mentioned: [Pg.217]    [Pg.217]    [Pg.1265]    [Pg.1947]    [Pg.222]    [Pg.341]    [Pg.767]    [Pg.295]    [Pg.437]    [Pg.485]    [Pg.391]    [Pg.412]    [Pg.767]    [Pg.4]    [Pg.13]    [Pg.164]    [Pg.384]    [Pg.6]    [Pg.385]    [Pg.5]    [Pg.3]    [Pg.550]    [Pg.551]    [Pg.142]    [Pg.3]    [Pg.191]    [Pg.212]    [Pg.276]    [Pg.457]    [Pg.445]    [Pg.166]    [Pg.411]    [Pg.734]    [Pg.737]    [Pg.341]    [Pg.2]    [Pg.88]    [Pg.372]    [Pg.155]    [Pg.183]    [Pg.74]    [Pg.103]   
See also in sourсe #XX -- [ Pg.173 ]




SEARCH



Method process

Processed method

Processing methods

Spectroscopic methods

Spectroscopic processes

© 2024 chempedia.info