Process sampling systems

The System 80+ Standard Design includes the Process Sampling System (see CESSAR-DC, Section 9.3.2) which is designed to... [Pg.332]

The Process Sampling System design meets the performance criteria described below and further discussed in CESSAR-DC, Section 9.3.2.1.1 ... [Pg.333]

In summary, the Process Sampling System fulfills the applicable requirements of 10 CFR 50.34 (f) and meets the guidance... [Pg.334]

Criterion 71. Process sampling systems and postaccident sampling systems Process sampling systems and postaccident sampling systems shall he designed so that the dose to an operator taking samples from these systems is ALARA. [Pg.463]

Generally, Httle is known in advance concerning the degree of homogeneity of most sampled systems. Uniformity, rarely constant throughout bulk systems, is often nonrandom. During the production of thousands of tons of material, size and shape distribution, surface and bulk composition, density, moisture, etc, can vary. Thus, in any bulk container, the product may be stratified into zones of variable properties. In gas and Hquid systems, particulates segregate and concentrate in specific locations in the container as the result of sedimentation (qv) or flotation (qv) processes. [Pg.297]

Application The zirconia oxygen sensor is widely used for combustion control processes and for air/fuel ratio regulation in internal combustion engines. The closed-end portion of the electrode tube is inserted into the exhaust gas stream. In the control of industrial combustion processes, no out stack sampling system is required. [Pg.1308]

Due to the nature of the SMB process, in-process samples of the unwanted enantiomer and the enantiopure drug substance can be sampled at controlled times during the continuous process to assess the enantiomeric and chemical purity. One can monitor the process without system shutdown by diverting either the extract or the raffinate streams. Further monitoring of the receiving tanks can also be accomplished. [Pg.277]

Many years have passed since the early days of AFM, when adhesion was seen as a hindrance, and it is now regarded as a useful parameter for identification of material as well as a key to understanding many important processes in biological function. In this area, the ability of AFM to map spatial variations of adhesion has not yet been fully exploited but in future could prove to be particularly useful. At present, the chemical nature and interaction area of the AFM probe are still rarely characterized to a desirable level. This may be improved dramatically by the use of nanotubes, carbon or otherwise, with functionalized end groups. However, reliance on other measurement techniques, such as transmission electron microscopy and field ion microscopy, will probably be essential in order to fully evaluate the tip-sample systems under investigation. [Pg.56]

Quality control is intended to monitor and evaluate the performances of both food and human processes that contribute to food quality. The basic principle of this function is the control circle that involves (1) the taking of a process sample by the analysis or measuring unit, (2) determining whether process results meet set tolerances or limits, (3) judging the character and level of any discrepancy, and (4) application of corrective action to adjust the system to an acceptable level (Figure 7.1.1). A distinction is made between measuring and analysis, whereby the first involves direct measurements (e.g., pH, temperature) and the second involves taking samples, sample preparation, and actual analysis. ... [Pg.555]

NeSSI s driver is to simplify and standardize sample system design. There is also a huge opportunity to adapt the emerging class of lab-on-a-chip sensors to a miniature/modular smart manifold which could fundamentally change the way in which industry does process analysis. [Pg.22]

In several chapters we discussed how the quality of the analytical result defines the amount of information which is obtained on a sampled system. Obvious quality criteria are accuracy and precision. An equally important criterion is the analysis time. This is particularly true when dynamic systems are analyzed. For instance a relationship exists between the measurability and the sampling rate, analysis time and precision (see Chapter 20). The monitoring of environmental and chemical processes are typical examples where the management of the analysis time is... [Pg.609]

Sample preparation, injection, calibration, and data collection, must be automated for process analysis. Methods used for flow injection analysis (FLA) are also useful for reliable sampling for process LC systems.1 Dynamic dilution is a technique that is used extensively in FIA.13 In this technique, sample from a loop or slot of a valve is diluted as it is transferred to a HPLC injection valve for analysis. As the diluted sample plug passes through the HPLC valve it is switched and the sample is injected onto the HPLC column for separation. The sample transfer time typically is determined with a refractive index detector and valve switching, which can be controlled by an integrator or computer. The transfer time is very reproducible. Calibration is typically done by external standardization using normalization by response factor. Internal standardization has also been used. To detect upsets or for process optimization, absolute numbers are not always needed. An alternative to... [Pg.76]


See other pages where Process sampling systems is mentioned: [Pg.523]    [Pg.351]    [Pg.523]    [Pg.351]    [Pg.91]    [Pg.397]    [Pg.716]    [Pg.766]    [Pg.766]    [Pg.1897]    [Pg.180]    [Pg.294]    [Pg.323]    [Pg.33]    [Pg.278]    [Pg.6]    [Pg.24]    [Pg.25]    [Pg.25]    [Pg.247]    [Pg.162]    [Pg.22]    [Pg.78]    [Pg.318]    [Pg.77]    [Pg.77]    [Pg.83]    [Pg.107]    [Pg.111]    [Pg.204]    [Pg.10]    [Pg.601]    [Pg.740]    [Pg.289]    [Pg.76]    [Pg.243]    [Pg.497]    [Pg.522]   
See also in sourсe #XX -- [ Pg.28 , Pg.29 , Pg.30 ]




SEARCH



Engineering 2 Process Analyzer and Sample-handling System

Integrated microfluidic systems, sample processing with

Process Sample

Process analyzers, sampling systems

Process sampling

Sample processing

Sampling Systems for Process Analyzers