Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Process evaluation storage tanks

Any site with underground storage tanks (USTs) should be thoroughly assessed. Older tanks need to be checked for rust and leaks, and all USTs must be evaluated and maintained regularly. Underground gasoline tanks must, by law in many states, be noncotrosive replacement of old, corrosive tanks is an expensive process. [Pg.1489]

Every facility can benefit from a review of its infrastructure. This includes all utilities, entrances/exits, process and production equipment, telephone and data lines, water supply, backup power systans, process controls, hazardous material storage tanks and pits, fire alarm systems, and sprinkler systems. Making a list of all infrastructure details is helpful when evaluating security vulnerability, as well as such mundane tasks as budget analysis, routine and preventive maintenance, and personnel responsibilities. [Pg.97]

This process of event classification, in which initiators of all types, both internal and external to the plant, and all modes of operation, including normal operation, shutdown and refuelling, are considered, should lead to a list of different classes of plant specific events to be analysed. Different plant conditions, such as manual control or automatic control, should be investigated. Different site conditions, such as the availability of off-site power or the total loss of off-site power, should also be evaluated, with account taken of the possible interactions between plant manoeuvres and the grid and, where appropriate, possible interactions between different reactor units on the same site. Failures in other plant systems, such as the storage for irradiated fuel and storage tanks for radioactive gas, should also be considered. [Pg.41]

State 2, At time 0, at the end of the cooldown period, the control volume is filled with liquid in thermal equilibrium with the pipe wall. The mean liquid properties are evaluated at a saturation pressure, which is the arithmetic mean of atmospheric pressure and storage tank pressure, (At the end of cooldown, the liquid at the downstream end of the line is saturated at the local pressure, which is approximately equal to storage tank pressure, since we assume negligible pressure drop in the liquid phase during the cooldown process. The liquid at the upstream end of the line, which has just left the vacuum insulated storage tank, will be saturated at atmospheric pressure. Therefore, the average liquid properties can be determined from the mean saturation pressure mentioned above.)... [Pg.386]

As can be seen from the Global Reactive Chemicals Standard, all existing chemical processes will have a Reactive Chemicals/Process Hazard Analysis review on a predefined periodic basis. In addition, every new plant Production Leader should review their process with the Reactive Chemicals Committee within 90 days of assuming responsibility for a pilot or production plant. Prior to the review, the Leader should acquire training on the chemistry and processes that they are working with. This should include an evaluation of raw materials, processes, products and waste to understand any potential reactive chemical hazards. They should review and be prepared to answer questions from the completed and updated RC/PHA protocol questionnaire as well as other relevant materials in their plant Process Safety Folder, such as F EI, CEI, etc. The review should cover all auxiliary operations to the process such as raw material and product storage drum, tank car and truck loading. [Pg.227]


See other pages where Process evaluation storage tanks is mentioned: [Pg.37]    [Pg.950]    [Pg.642]    [Pg.92]    [Pg.427]    [Pg.580]    [Pg.1846]    [Pg.45]    [Pg.150]    [Pg.9]    [Pg.158]    [Pg.326]    [Pg.54]    [Pg.338]    [Pg.1457]    [Pg.514]   


SEARCH



Evaluative Process

Process evaluation

Storage processes

Storage tank

© 2024 chempedia.info