Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Prednisone tablets

Available 50 mg Benadryl capsules weighing 200 mg, and 4 mg prednisone tablets weighing 180 mg each. [Pg.132]

The prednisone tablets use deaerated water as the medium. There are numerous methods for deaeration of medium (14,22). As mentioned above, there are also automated methods available. The method described in <711> uses heat, filtration, and vacuum. Helium sparging is also a typical method... [Pg.59]

Campagna FA, Cureton G, Mirigian RA, Nelson E. Inactive prednisone tablets USP XVI. J Pharm Sci 1963 52 605-606. [Pg.79]

The apparatus suitability test described in USP General Chapter <711> Dissolution is equivalent to a performance qualification.5 The determination of suitability of a test assembly to perform dissolution testing must include conformance to the dimensions and tolerances of the apparatus. In addition, the critical test parameters that have to be monitored periodically include volume and temperature of the dissolution medium, rotation speed (Apparatuses 1 and 2), dip rate (Apparatus 3), and flow rate of medium (Apparatus 4). This test requires that the USP Calibrator Tablets (now known as Performance Verification Standard Tablets) be tested the dissolution results must be within the ranges stated in the certificate of the calibrator tablets. The performance verification standard tablets include USP Chlorpheniramine Maleate Extended-Release Tablets RS, USP Prednisone Tablets RS, and USP Salicylic Acid Tablets RS. [Pg.267]

Savage, T.S. Wells, C.E. Automated sampling of in vitro dissolution medium effect of sampling probes on dissolution rate of prednisone tablets. J. Pharm. Sci. 1982, 71, 670-673. [Pg.928]

C. J. Taborsky-Urdinola, V. A. Gray, and L. T. Grady, Effects of packaging and storage on the dissolution of model prednisone tablets, Am. J. Hosp. Pharm. 38, 1322-1327(1981). [Pg.254]

Reference tablets of known dissolution rate are available from the USP to determine apparatus suitability. Prednisone tablets (disintegrating) and salicylic acid tablets (nondisintegrating) may be used to check the calibration of the basket, paddle, and flow-through apparatuses. Chlorpheniramine extended-release tablets and theophylline extended-release beads have recently become available for checking the calibration of the reciprocating cylinder apparatus. [Pg.3643]

A controlled trial of inhaled corticosteroids in patients receiving prednisone tablets for asthma. Brit. J. Dis. Chest, 70, 95. [Pg.287]


See other pages where Prednisone tablets is mentioned: [Pg.14]    [Pg.59]    [Pg.73]    [Pg.285]    [Pg.501]    [Pg.677]    [Pg.157]    [Pg.920]    [Pg.921]    [Pg.1874]    [Pg.3564]    [Pg.159]    [Pg.8]    [Pg.366]    [Pg.161]    [Pg.157]    [Pg.484]    [Pg.1160]    [Pg.647]   
See also in sourсe #XX -- [ Pg.159 ]

See also in sourсe #XX -- [ Pg.596 ]




SEARCH



© 2024 chempedia.info