Polymer-ligand interaction

The aselectivity is explained as follows. During the transition state for olefin insertion, the two a-hydrogens have an almost equal chance (ignoring the usually minimal effect of chain-end control ) of occupying the a-agostic position because of the similar repulsive polymer-ligand interactions... [Pg.685]

Several different analytical and ultra-micropreparative CEC approaches have been described for such peptide separations. For example, open tubular (OT-CEC) methods have been used 290-294 with etched fused silicas to increase the surface area with diols or octadecyl chains then bonded to the surface.1 With such OT-CEC systems, the peptide-ligand interactions of, for example, angiotensin I-III increased with increasing hydrophobicity of the bonded phase on the capillary wall. Porous layer open tubular (PLOT) capillaries coated with anionic polymers 295 or poly(aspartic acid) 296 have also been employed 297 to separate basic peptides on the inner wall of fused silica capillaries of 20 pm i.d. When the same eluent conditions were employed, superior performance was observed for these PLOT capillaries compared to the corresponding capillary zone electrophoresis (HP-CZE) separation. Peptide mixtures can be analyzed 298-300 with OT-CEC systems based on octyl-bonded fused silica capillaries that have been coated with (3-aminopropyl)trimethoxysilane (APS), as well as with pressurized CEC (pCEC) packed with particles of similar surface chemistry, to decrease the electrostatic interactions between the solute and the surface, coupled to a mass spectrometer (MS). In the pressurized flow version of electrochromatography, a pLC pump is also employed (Figure 26) to facilitate liquid flow, reduce bubble formation, and to fine-tune the selectivity of the separation of the peptide mixture. [Pg.619]

The dispersion effect of water-soluble polymers on a heme aggregate is mentioned below. However, these water-soluble polymers have no coordinating ability and are not polymer ligands. It is well known that heme and its complexes easily aggregate in aqueous solution by stacking interaction, and that stable monomeric dispersed heme complexes are formed under restricted conditions such as extremely low concentration and low ionic strength21,22 ... [Pg.18]

On the spectroscopic measurement, the hyperchromicity observed at the d—d first absorption band of Fe(II)(phen)3(510 nm) was caused by the hydrophobic interaction between polymer ligands and the bulky phenantroline ring. The magnitude of hyperchromicity decreases in the order Fe(II)(phen)3 mixed with poly(N-vinyl-... [Pg.43]

PVP(DP 98)-Co(Ilf) > PVP(DP 19)-Co(III) > N-ethylimidazole-Co(III) - pyridine-Co(III), and this order agrees with that of the reactivity. The hydrophobic interaction between polymer ligands and Fe(II)(phen)3 is considered to account for the higher reactivity of the polymer complexes. [Pg.44]

Random polypeptides have traditionally been synthesized by copolymerization of amino acid NCAs. Methods for the synthesis and application of random copolymers have been extensively reviewed (e.g., ref1221), and thus only a single example is given here. A second class of random polypeptides includes organized polymeric assemblies that incorporate bioactive sequences and/or structures. Such polymers have been developed for modulation of protein-ligand interactions/231 protein adsorption to surfaces/241 and cell adhesion/25-281 Several examples for the synthesis of these polymeric assemblies are provided below. [Pg.172]

Many interesting features have been observed in the complex formation between polymer ligands and metal ions. Coulombic, hydrophobic, and steric interactions are major factors governing the thermochemical and dynamic aspects of complex formation. [Pg.106]

PBDA and BDA with some transition metal ions are shown in Table 1. For the polymer ligand, the complexation process appears to proceed in two steps a) accumulation of M2 + ions into the PBDA domain (pre-equilibrium process) due to electrostatic interaction of the anionic polymer backbone of PBDA with M2+,... [Pg.110]

Other important methods of synthesis of coordination compounds are discussed in detail [1,3,10,11,53,201,202,206,207,316,318,322,690]. In this respect, we emphasize the synthesis of metal-polymers [690,691] and preparation of complexes in the solid phase (mechano- or tribosynthesis) [10,201,202,206]. Additionally to the above-described techniques, the general methods and principles of synthesis of coordination compounds are used to obtain metal-polymers (immediate interaction of polymer ligands and metal salts, template electrosynthesis, polymer-analogous transformations). The last method consists of the polymerization of metal-monomers (metal-containing monomers) and fixation of metal complexes on the polymer... [Pg.276]

The compound [Ca(hfac)2(H20)2]2153 (Fig. 38) is a centrosymmetric dimer in the solid state, while the analogous barium complex, [Ba(hfac)2 (H20)]x,153 exists as a polymer. Both compounds have M-F interactions similar to those described for [Ba2(hfac)4(Et20)L The smaller size of calcium is probably responsible for the structural differences between these two water adducts. The volatility of these fluorinated complexes is certainly decreased by the M-F interactions, as well as by the overall oligomeric structure of the compounds. What relationship metal ligand interactions of this type play in the incorporation of BaF2 in films prepared from these compounds has not yet been elucidated. Interestingly, no base-free fluorinated /3-diketonate compounds have been structurally characterized. [Pg.281]

With spin labelled (7b) the metal chelate coordinated by polymer ligands in toluene or in the solid state shows lower ESR movement than the chelates coordinated by low molecular ligand. So the p< sibility of dimer-dimer-interaction during oxygenation leading to irreversible oxidation is reduced. Aggregates of (7a)-pyridine complexes dis-... [Pg.55]


See other pages where Polymer-ligand interaction is mentioned: [Pg.486]    [Pg.487]    [Pg.488]    [Pg.486]    [Pg.487]    [Pg.488]    [Pg.163]    [Pg.255]    [Pg.40]    [Pg.56]    [Pg.209]    [Pg.132]    [Pg.21]    [Pg.22]    [Pg.370]    [Pg.444]    [Pg.277]    [Pg.108]    [Pg.109]    [Pg.131]    [Pg.159]    [Pg.161]    [Pg.19]    [Pg.21]    [Pg.21]    [Pg.82]    [Pg.256]    [Pg.109]    [Pg.609]    [Pg.90]    [Pg.202]    [Pg.71]    [Pg.285]    [Pg.153]    [Pg.163]    [Pg.118]    [Pg.307]    [Pg.5721]    [Pg.59]    [Pg.118]   
See also in sourсe #XX -- [ Pg.487 ]




SEARCH



Ligand interactions

Ligand polymer

Polymers interactions

Two Identical Sites on a Polymer Direct Interaction between the Ligands