Besides silicon, other materials have also been used in micro fuel cells. Cha et al. [79] made micro-FF channels on SU8 sheets—a photosensitive polymer that is flexible, easy to fabricate, thin, and cheaper than silicon wafers. On top of fhe flow channels, for both the anode and cathode, a paste of carbon black and PTFE is deposited in order to form the actual diffusion layers of the fuel cell. Mifrovski, Elliott, and Nuzzo [80] used a gas-permeable elastomer, such as poly(dimethylsiloxane) (PDMS), as a diffusion layer (with platinum electrodes embedded in it) for liquid-electrolyte-based micro-PEM fuel cells. [Pg.223]

A stopped-flow setup can relatively easily be equipped with multispectral detection. The fluorescence light is emitted from a small spot in the flow channel. Therefore the flow cell can be placed directly in the input slit plane of a poly-chromator. The spectram is detected by a multianode PMT. The photons detected in the spectral channels are recorded simultaneously by a TCSPC device and a router. However, although the implementation is relatively simple, no spectrally resolved TCSPC-based stopped-flow system has yet been described. [Pg.97]

A third way to build up pFCs based on MEMS-polymers such as poly-dimethylsiloxane (PDMS) or polymethyl methacrylate (PMMA) or PCB-materials such as polyimid (PI) or FR4. These polymers can be micro-machined by molding or by laser ablation. Shah et al. [22,23] have developed a complete PEMFC system consisting of a PDMS substrate with micro-flow channels upon which the MEA was vertically stacked. PDMS micro-reactors were fabricated by employing micro-molding with a dry etched silicon master. The PDMS spin coated on micro-machined Si was then cured and peeled off from the master. The MEA employed consisted in a Nafion - 12 membrane where they have sputtered Pt through a Mylar mask. Despite an interesting method, this FC gave poor results, a power density of 0.8 mW cm was achieved. [Pg.128]

Another approach involved the use of a carbonate membrane bonded to SU8 channels with a glass layer used to seal the device [29]. The system used a stacked approach with a dialysis membrane sandwiched between an SU8 perfusion channel and a poly(dimethylsiloxane) flow channel (Figure 48.4). Bonding the membrane reduced the chance of leakage and resulted in a more robust device. A fluorescent dye and glucose solution were used for optical characterization of the system. A eommercially available glucose sensor was used to determine the concentration of glucose in the dialysate. A recovery of 80% was obtained at flow rate of 1.5 tiL/min. [Pg.1331]

Fig. 6 SEM cross-sectional views of two grooved structures (a) hemispherical grooves made from monocrystalline silicon, (b) flow channels produced from poly- and monocrystalline siUcon (Ben Jaballah et al. 2005), and (c) UNO3/HF vapor-etched NaOH-textured c-Si wafer (Saadoun et al. 2011)... Fig. 6 SEM cross-sectional views of two grooved structures (a) hemispherical grooves made from monocrystalline silicon, (b) flow channels produced from poly- and monocrystalline siUcon (Ben Jaballah et al. 2005), and (c) UNO3/HF vapor-etched NaOH-textured c-Si wafer (Saadoun et al. 2011)...
In this method, NWs can be aligned by passing a suspension of NWs through microfluidic channel structures, for example, formed between a poly(dimethylsiloxane) (PDMS) mold 49 and a flat substrate (Fig. 11.3a). Images of NWs assembled on substrate surfaces (Fig. 11.3b) within micro-fluidic flows demonstrate that virtually all NWs are aligned along the flow direction. This alignment readily extends over hundreds of micrometers, and... [Pg.354]

Diffusion medium properties for the PEFC system were most recently reviewed by Mathias et al. The primary purpose of a diffusion medium or gas diffusion layer (GDL) is to provide lateral current collection from the catalyst layer to the current collecting lands as well as uniform gas distribution to the catalyst layer through diffusion. It must also facilitate the transport of water out of the catalyst layer. The latter function is usually fulfilled by adding a coating of hydrophobic polymer such as poly(tet-rafluoroethylene) (PTFE) to the GDL. The hydrophobic polymer allows the excess water in the cathode catalyst layer to be expelled from the cell by gas flow in the channels, thereby alleviating flooding. It is known that the electric conductivity of GDL is... [Pg.492]

The microreactor system consists of a pumping module (R2+) and a four-channel heated component (R4). Two independently conducted flow streams are mixed in a T-piece and driven through a convection-flow coil (CFC, volume 10 ml) made of poly(fluoroacetate) (PFA). After the CFC, the flow is guided through Omnifit glass columns [41] packed with immobilized scavengers. [Pg.174]

Beider et al. [90] described poly (vinyl alcohol) coated microfluidic devices in NCE for a suppressed electroosmotic flow and improved separation performance of labeled amines. A threefold increase in separation efficiencies was obtained on coated chips. In PVA-coated channels, rinsing or etching steps could be omitted, which are necessary for uncoated devices. Wu et al. [100] described multilayer poly(vinyl alcohol)-adsorbed coating on... [Pg.40]

Wang, B., Chen, L., AbdulaM-Kanji, Z., Horton, J.H., Oleschuk, R.D., Aging effects on oxidized and amine-modified poly(dimethylsiloxane) surfaces studied with chemical force titrations Effects on electroosmotic flow rate in microfluidic channels. Langmuir, 2003, 19, 9792-9798. [Pg.412]

Plastic microdevices for high-throughput screening with MS detection were also prepared for detection of aflatoxins and barbiturates. These devices incorporated concentration techniques interfaced with electrospray ionization MS (ESI-MS) through capillaries [2], The microfluidic device for aflatoxin detection employed an affinity dialysis technique, in which a poly (vinylidene fluoride) (PVDF) membrane was incorporated in the microchip between two channels. Small molecules were dialyzed from the aflatoxin/antibody complexes, which were then analyzed by MS. A similar device was used for concentrating barbiturate/antibody complexes using an affinity ultrafiltration technique. A barbiturate solution was mixed with antibodies and then flowed into the device, where uncomplexed barbiturates were removed by filtration. The antibody complex was then dissociated and electrokinetically mobilized for MS analysis. In each case, the affinity preconcentration improved the sensitivity by at least one to two orders of magnitude over previously reported detection limits. [Pg.429]


See other pages where Poly flow channel is mentioned: [Pg.347]    [Pg.25]    [Pg.644]    [Pg.288]    [Pg.391]    [Pg.3116]    [Pg.140]    [Pg.92]    [Pg.104]    [Pg.272]    [Pg.690]    [Pg.656]    [Pg.134]    [Pg.391]    [Pg.122]    [Pg.58]    [Pg.830]    [Pg.40]    [Pg.75]    [Pg.80]    [Pg.95]    [Pg.198]    [Pg.203]    [Pg.35]    [Pg.89]    [Pg.288]    [Pg.565]    [Pg.131]    [Pg.282]    [Pg.613]    [Pg.165]    [Pg.656]    [Pg.787]    [Pg.1838]    [Pg.1049]    [Pg.211]    [Pg.463]    [Pg.1288]    [Pg.1426]   