Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Molecular phosphorescence spectroscopy

Typical singlet lifetimes are measured in nanoseconds while triplet lifetimes of organic molecules in rigid solutions are usually measured in milliseconds or even seconds. In liquid media where drfifiision is rapid the triplet states are usually quenched, often by tire nearly iibiqitoiis molecular oxygen. Because of that, phosphorescence is seldom observed in liquid solutions. In the spectroscopy of molecules the tenn fluorescence is now usually used to refer to emission from an excited singlet state and phosphorescence to emission from a triplet state, regardless of the actual lifetimes. [Pg.1143]

The basic design of instrumentation for monitoring molecular fluorescence and molecular phosphorescence is similar to that found for other spectroscopies. The most significant differences are discussed in the following sections. [Pg.427]

McGown, L.B., and Warner, I.M. (1990) Molecular fluorescence, phosphorescence, and chemiluminescence spectroscopy. Anal. Chem. 190, 255R. [Pg.1093]

The major reasons for using intrinsic fluorescence and phosphorescence to study conformation are that these spectroscopies are extremely sensitive, they provide many specific parameters to correlate with physical structure, and they cover a wide time range, from picoseconds to seconds, which allows the study of a variety of different processes. The time scale of tyrosine fluorescence extends from picoseconds to a few nanoseconds, which is a good time window to obtain information about rotational diffusion, intermolecular association reactions, and conformational relaxation in the presence and absence of cofactors and substrates. Moreover, the time dependence of the fluorescence intensity and anisotropy decay can be used to test predictions from molecular dynamics.(167) In using tyrosine to study the dynamics of protein structure, it is particularly important that we begin to understand the basis for the anisotropy decay of tyrosine in terms of the potential motions of the phenol ring.(221) For example, the frequency of flips about the C -C bond of tyrosine appears to cover a time range from milliseconds to nanoseconds.(222)... [Pg.52]

It is now clear that in the absence of molecular oxygen most proteins phosphoresce in aqueous solutions at ambient temperature.(10) In this chapter we discuss the use of phosphorescence of tryptophan to study proteins, with emphasis on measurements at room temperature. Comparisons between phosphorescence and the more commonly used fluorescence spectroscopy are made. Comprehensive reviews of protein luminescence have been written by Longworth.(n 12 1 A discussion on the use of phosphorescence at room temperature for the study of biological materials was given by Horie and Vanderkooi.(13)... [Pg.114]

The identification and quantitative determination of specific organic compounds in very complex samples is an area of intense current research activity in analytical chemistry Optical spectroscopy (particularly UV-visible and infrared absorption and molecular fluorescence and phosphorescence techniques) has been used widely in organic analysis. Any optical spectroscopic technique to be used for characterization of a very complex sample, such as a coal-derived material, should exhibit very high sensitivity (so that trace constituents can be determined) and extremely great selectivity (so that fractionation and separation steps prior to the actual analysis can be held to the minimum number and complexity). To achieve high analytical selectivity, an analytical spectroscopic technique should produce highly structured and specific spectra useful for "fingerprinting purposes," as well as to minimize the extent of overlap of spectral bands due to different constituents of complex samples. [Pg.248]

A number of less commonly used analytical techniques are available for determining PAHs. These include synchronous luminescence spectroscopy (SLS), resonant (R)/nonresonant (NR)-synchronous scan luminescence (SSL) spectrometry, room temperature phosphorescence (RTP), ultraviolet-resonance Raman spectroscopy (UV-RRS), x-ray excited optical luminescence spectroscopy (XEOL), laser-induced molecular fluorescence (LIMP), supersonic jet/laser induced fluorescence (SSJ/LIF), low- temperature fluorescence spectroscopy (LTFS), high-resolution low-temperature spectrofluorometry, low-temperature molecular luminescence spectrometry (LT-MLS), and supersonic jet spectroscopy/capillary supercritical fluid chromatography (SJS/SFC) Asher 1984 Garrigues and Ewald 1987 Goates et al. 1989 Jones et al. 1988 Lai et al. 1990 Lamotte et al. 1985 Lin et al. 1991 Popl et al. 1975 Richardson and Ando 1977 Saber et al. 1991 Vo-Dinh et al. 1984 Vo- Dinh and Abbott 1984 Vo-Dinh 1981 Woo et al. 1980). More recent methods for the determination of PAHs in environmental samples include GC-MS with stable isotope dilution calibration (Bushby et al. 1993), capillary electrophoresis with UV-laser excited fluorescence detection (Nie et al. 1993), and laser desorption laser photoionization time-of-flight mass spectrometry of direct determination of PAH in solid waste matrices (Dale et al. 1993). [Pg.347]


See other pages where Molecular phosphorescence spectroscopy is mentioned: [Pg.138]    [Pg.834]    [Pg.95]    [Pg.490]    [Pg.69]    [Pg.567]    [Pg.424]    [Pg.432]    [Pg.301]    [Pg.6]    [Pg.277]    [Pg.209]    [Pg.209]    [Pg.4]    [Pg.310]    [Pg.106]    [Pg.163]    [Pg.166]    [Pg.6]    [Pg.360]    [Pg.87]    [Pg.26]    [Pg.43]    [Pg.37]    [Pg.3389]    [Pg.333]    [Pg.43]    [Pg.369]    [Pg.24]    [Pg.35]    [Pg.261]    [Pg.257]    [Pg.4]    [Pg.399]    [Pg.35]    [Pg.44]   
See also in sourсe #XX -- [ Pg.373 ]




SEARCH



Molecular spectroscopy

Phosphoresce

Phosphorescence

Phosphorescence spectroscopy

Phosphorescent

© 2024 chempedia.info