Parallel operation power generation

This device controls the generator and maintains a steady-stale armature voltage automatically within the predefined limits. It also serves to control the reactive kVAr loading during a parallel operation or when the machine is being used as a synchronous condenser for reactive power compensation through a quadrature droop control (QDC) as noted below. [Pg.502]

Desiccant dehumidifiers reduce humidity in the air by using solid desiccant materials or liquid desiccant materials to attract and hold moisture. They can operate independent of chillers and can also be operated in series or parallel with chillers. Recoverable heat from the exhaust gases of turbines and engines for power generation or engine-driven chillers is used for regenerating desiccant material in these dehumidifiers. [Pg.476]

A thermionic converter with a plane parallel type of a polycrystalline W emitter and an AgO X collector, an interelectrode spacing at room temperature 0.1mm, was set up and the power generation experiments were conducted. The maximum power, 3.9W/cm, 0.6V, 6.5A/cm, was obtained under the unignited mode operation at T e =1583K. The barrier index was V b =1.5V at T e =1578K. Based on the experimental results, a new type of a FGM collector was proposed for a micro-gap thermionic converter. [Pg.647]

In parallel with these development, work has been carried out on phosphoric acid electrolyte fuel cells which operate at 200 C and are able to burn hydrogen containing CO2 impurity, using air rather than pure oxygen as the oxidant. They find application as combined heat and power generation in 40 kW sizes, while much larger units (4.8 MW) have been installed in Manhattan and in Tokyo for peak load generation in the electricity supply system[4]. [Pg.74]

Induction generators cannot operate independently in an isolated system. They can only function in parallel with synchronous generators that regulate voltage and supply the kilovars necessary to overcome the lagging power of the induction generation. [Pg.948]

In 1995, the functional tests have been performed without startup failures. The functional tests of the diesel generators are performed monthly at about 2.4 MW and yearly at nominal power (at 5.6 MW). A parallel operation of the diesel generator with the grid is not automatically planned, but it is used for functional tests. Possible causes of common cause failures are evaluated by the NPP. [Pg.157]

A typical cell generates a voltage of around 0.7 to 0.8 volts per cell and power outputs of a few tens or hundreds of watts. In order to achieve a significant output, cells have to be assembled in modules or stacks and electrically connected in series or in parallel. Different types of cells exist, according to the electrolyte used, and each type has a characteristic operating temperature (OT) ... [Pg.302]


See other pages where Parallel operation power generation is mentioned: [Pg.431]    [Pg.126]    [Pg.492]    [Pg.235]    [Pg.212]    [Pg.338]    [Pg.54]    [Pg.255]    [Pg.14]    [Pg.83]    [Pg.162]    [Pg.116]    [Pg.932]    [Pg.157]    [Pg.157]    [Pg.734]    [Pg.1000]    [Pg.724]    [Pg.1015]    [Pg.156]    [Pg.20]    [Pg.35]    [Pg.441]    [Pg.484]    [Pg.5]    [Pg.242]    [Pg.811]    [Pg.96]    [Pg.95]    [Pg.316]    [Pg.262]    [Pg.524]    [Pg.633]    [Pg.637]    [Pg.640]    [Pg.1345]    [Pg.68]    [Pg.543]    [Pg.48]    [Pg.425]    [Pg.335]    [Pg.43]    [Pg.229]   