Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Parallel linking

Parallel Link of Components The failure of the system requires the failure of both components. Note that there i9 no convenient way to combine the failure rate. ... [Pg.476]

Nissan s Hypermini concept EV is a two passenger EV (electric vehicle) that can go 60 miles per hour and travel about 75 miles on a single charge. It uses a neodynium magnet synchronous motor, with a maximum output of 20 kW at 15,000 rpm, lithium-ion batteries and an inductive charging system. Rear-wheel 2WD is used with front independent struts and rear independent parallel-link struts. The brakes are ventilated discs with an anti-lock system. [Pg.259]

Smith has also described the implementation of MD on parallel machines, with particular reference to hypercube computers. In work designed to introduce a novice to the main aspects of parallel computing in MD, Smith described three particular algorithms replicated data (RD), systolic loop (SLS-G), and parallelized link cells (PLC), all of which have good load balancing. The performance characteristics of each algorithm and the factors affecting... [Pg.256]

Several attempts have been made to relate these conductivity exponents tc or Sc with the percolation cluster statistical exponents discussed earlier. For example, in the node-link-blob model, the conductivity E of the network is proportional to the number of parallel links, while the... [Pg.15]

We expect a difference near pc. Since there are (L/ ) " number of parallel links between the two electrodes, the current in a link is given by zl = /L) I. The current density i in a channel of cross-section 6 is given by... [Pg.42]

Tarm (l/3A ) = 1/9A/. The force at the midpoint of the core CmiA depends on its structure. If the star has a linear core (Fig. 27a), in each of the three sets of arms add up to ffmid = 3fused core with three parallel bonds (Fig. 27b), c aid in each of the three parallel links would scale ffmid = [Pg.173]

IS measurements have been performed in the 253-333 K temperature range and the results from the measurement at 293 K are shown in Figure 3-43. The Argand diagram consists of two semidrcles which can be understood and represented by a best fit of the data to an ideal Debye resistance (/ 2)/capadtance (C2) parallel link (lower frequency process 2) in series with an additional Cole-Cole resistance (Ri)/CPE (constant phase element) parallel link (higher frequency process 1). From the fit data, a Cole-Cole parameter a = 2/3 results which is very typical for percolation mechanisms. The Ohmic part is the same for both processes Ri = and so = 2/ ,. The spedfic conductivity processes have Oi = 02 = 3.23 X 10 Q" m at 293 K. Since both processes are thermally... [Pg.200]

Therefore it can utilize the channel to establish a parallel link with another terminal that is out of range of B, for instance, terminal D. In this case C is termed the exposed terminal to B. Exposed terminals may result in under-usage of the channel. As in the hidden terminal problem, this also can be minimized with... [Pg.2103]

A parallel link connects the master processor to an I/O or memory slave via a set of parallel lines. Centronics has been used for years for the connection of printers and scanners, together with the serial RS232 explained in the next section. Both should disappear soon. PCMCIA has been defined for portable PCs and uses a 64-pin connector to connect a memory card or a modem, but also accepts disks and fast video devices. New standards will be defined for the coming smaller disks and flash memories, to be used mostly for picture cameras and wearable computers. [Pg.75]

A rope is in the reliability state subset 1,2,3, 2,3, 3, if all 6 strand are in this subset, so it is a series system. After some consultations with experts we assume that a strand does not satisfy technical conditions after breaking 6 of its 36 wires. With this assumption we conclude that a rope is in the reliability state subset 1,2,3, 2,3, 3, when all six strands of a rope are in this state subset and each of strands is in the reliability state subset 1,2,3, 2,3, 3, if at least 30 out of its 36 wires are in this state subset. Thus, we obtain that a rope is a regular 4-states 30 out of 36 -series system composed of k = 6 series-linked strands with 1=36 parallel-linked components (wires). As each broaching machine has only one rope we can say that broaching machines i.e. subsystems Si, Sj, S, are also regular 4-state 30 out of 36 -series systems. [Pg.260]


See other pages where Parallel linking is mentioned: [Pg.614]    [Pg.619]    [Pg.236]    [Pg.210]    [Pg.97]    [Pg.218]    [Pg.805]    [Pg.809]    [Pg.810]    [Pg.1558]    [Pg.336]    [Pg.1215]    [Pg.75]    [Pg.379]    [Pg.443]    [Pg.591]   


SEARCH



Linking, series/parallel

Parallel Cross-Linked Pores

Parallel network Term Links

Parallel-cross-linked pore model

Parallelized link cells algorithm

The Parallel Cross-Linked Pore Model

© 2024 chempedia.info