Packed columns control

For column analysis and troubleshooting it is important to have pressure drop measured with a DP cell. The differential pressure can also be used to control column traffic. A good way to do this would be to let the differential pressure control the heating medium to the reboiler. The largest application for differential pressure control is with packed columns where it is desirable to run at 80 to 100% of flood for best efficiency. [Pg.69]

Each of the PLgel individual pore sizes is produced hy suspension polymerization, which yields a fairly diverse range of particle sizes. For optimum performance in a chromatographic column the particle size distribution of the beads should be narrow this is achieved by air classification after the cross-linked beads have been washed and dried thoroughly. Similarly, for consistent column performance, the particle size distribution is critical and is another quality control aspect where both the median particle size and the width of the distribution are specified. The efficiency of the packed column is extremely sensitive to the median particle size, as predicted by the van Deemter equation (4), whereas the width of the particle size distribution can affect column operating pressure and packed bed stability. [Pg.352]

Packed columns are used for the continuous contact between liquid and gas. The countercurrent packed column is the most common type of unit encountered in gaseous pollutant control for the removal of the undesirable gas. [Pg.139]

Three column sets were used in this study. All consisted of 0.95 X 122 cm stainless steel columns slurry packed with Control-led-Pore Glass from Electronucleonics. The configurations were ... [Pg.31]

Implementation of SFC has initially been hampered by instrumental problems, such as back-pressure regulation, need for syringe pumps, consistent flow-rates, pressure and density gradient control, modifier gradient elution, small volume injection (nL), poor reproducibility of injection, and miniaturised detection. These difficulties, which limited sensitivity, precision or reproducibility in industrial applications, were eventually overcome. Because instrumentation for SFC is quite complex and expensive, the technique is still not widely accepted. At the present time few SFC instrument manufacturers are active. Berger and Wilson [239] have described packed SFC instrumentation equipped with FID, UV/VIS and NPD, which can also be employed for open-tubular SFC in a pressure-control mode. Column technology has been largely borrowed from GC (for the open-tubular format) or from HPLC (for the packed format). Open-tubular coated capillaries (50-100 irn i.d.), packed capillaries (100-500 p,m i.d.), and packed columns (1 -4.6 mm i.d.) have been used for SFC (Table 4.27). [Pg.206]

The selection of the column type is mainly determined by the composition of the sample. In general open-tubular (capillary) columns are preferred for low-density (gas-like) SFC, whereas packed columns are most useful for high-density (liquid-like) SFC. Open-tubular columns can provide a much larger number of theoretical plates than packed columns for the same pressure drop. Volumetric flow-rates are much higher in packed column SFC (pSFC) than in open-tubular column SFC (cSFC), which makes injection and flow control less problematic. [Pg.207]

Differential pressure control is often used on packed columns to ensure that the packing operates at the correct loading see Figure 5.22d (see p. 234). [Pg.233]

ECKERT, J. S. (1964) Chem. Eng., NY 71 (Mar. 30th) 79. Controlling packed-column stills. [Pg.238]


See other pages where Packed columns control is mentioned: [Pg.241]    [Pg.1434]    [Pg.1439]    [Pg.1815]    [Pg.357]    [Pg.407]    [Pg.76]    [Pg.352]    [Pg.446]    [Pg.58]    [Pg.328]    [Pg.302]    [Pg.228]    [Pg.414]    [Pg.301]    [Pg.742]    [Pg.80]    [Pg.110]    [Pg.121]    [Pg.283]    [Pg.288]    [Pg.322]    [Pg.325]    [Pg.638]    [Pg.680]    [Pg.695]    [Pg.818]    [Pg.832]    [Pg.832]    [Pg.910]    [Pg.196]    [Pg.208]    [Pg.208]    [Pg.234]    [Pg.312]    [Pg.126]    [Pg.541]    [Pg.173]    [Pg.106]   
See also in sourсe #XX -- [ Pg.284 ]