In addition to the speed control system, a second overspeed system was developed to prevent operation of a rotor above its maximum rated... [Pg.317]

In addition to the various turbine trips, two independent and redundant overspeed trip systems, the mechanical overspeed trip (OST) system and the electronic overspeed system (EOS), are provided to trip turbines at 110% and 111% of rated speed, respectively. Therefore, this system is considered to meet the regulatory requirements. [Pg.239]

Steam turbine considerations. The speed at whieh the turbine must operate and the steam eonditions available influenee the operating effieieney of the unit. Double-ended steam turbines require speeial eonsideration of thrust bearing sizing, overspeed proteetion, and governing systems. [Pg.221]

The expander shall be equipped with an eleetronie overspeed trip. The piekups shall sense the rotation of a 30-tooth wheel and be eonneeted to a 2-out-of-3 voting system. [Pg.315]

A typieal TPG valve arrangement is the five valve system (Figure 6-41). The two expander inlet valves provide regenerator pressure eontrol, overspeed proteetion, and flue gas shut-off to the expander. The expander exhaust valve enables expander isolation. The full and partial expander bypass valves permit aeeurate eontrol of the FCC proeess when the expander is not in operation. [Pg.378]

Check valves are required in the piping system at any point where backflow of gas after a shutdown has the ability to restart the compressor, running it backwards or, for that matter, even in the normal direction. Reverse rotation is totally bad, as many components of the various compressor types are not designed for reverse rotation, and there is some possibility, generally remote, that the compressor could reach a destructive over speed. Forward rotation is bad primarily because the intent was to stop the compressor, and it is now operating out of control. This is a problem, particularly if the shutdown was caused by a compressor failure indication, and the need to stop was to prevent further damage. In this mode, it is unlikely that the compressor can attain an overspeed condition. An application with a high potential for backflow is the parallel operation of two or more compressors. [Pg.472]

On the morning of January 22, 1972, a 44-car cut was being classified. One car, an empty hopper, was humped without incident but stopped approximately 400 m (1300 ft) short of its planned coupling point. Later, three tank cars containing propylene were humped as a unit and directed onto the same track as the empty hopper. The cars should have been slowed by the speed control system, but were not, probably because of greasy wheels. An overspeed alarm was given. The unit ran into the empty hopper at a speed of approximately 25 km/h (15 mph). [Pg.20]

E.3.3.3 Rotor systems that have low inertia and are subject to accidental unloading should be equipped with a quick-acting brake to prevent damage from overspeed. [Pg.115]

Normal Consequence—Class 3. All other containment equipment or instrumentation serving the operation whose failure could result in minor environmental releases, property or production losses, or injury to personnel or reduced economic life. It may include less critical refrigeration systems, turbine overspeed trips, lubrication system alarms and similar important, but not crucial items. [Pg.205]

The unit is fully protected with safety valves at necessary points. In addition the compressor has water temperature and pressure shutoff switches, and a suction pressure switch, which will shut it down in the event the system runs low on gas. This protects against line bursts or major leaks, or operator negligence in providing gas supply. The expander has overspeed and oil-pressure protection. The expander and compressor are linked with a unique electrical circuit, which permits them to be started separately, but which shuts down both units in case of automatic shutdown of either one. Thus any failure will close down the entire system, preventing damage to either compressor or expander. [Pg.505]

Flow High 1. Failure of level control system in T-lOO 2. Pump overspeed... [Pg.249]

In addition to the normal speed control function provided by the turbine control system, a separate turbine overspeed protection system is included to minimize the possibility of turbine failure and high energy missile damage. [Pg.92]

Steam enters a turbine through the steam chest. The steam chest typically has a strainer on the inlet side to remove solids. Inside the steam chest is a device called the governor valve. The governor valve opens and closes to admit steam into the turbine. A governor system controls the position of the governor valve. An overspeed trip mechanism is attached to the rotor and will shut off the flow of steam into the turbine when it reaches 115% of its design limit. The shutoff valve is typically located in front of the governor valve. [Pg.132]

Critical interlock While identifying the hazards it is important to categorize critical interlocks (for new plants, data/experience from similar plants may be helpful) for which sufficient backup may have to be arranged as a safety measure. In many of these cases, in addition to software interlock, hardware interlocks are also provided. In some cases, even mechanical protection is provided. A critical trip interlock pertinent to a turbine is an example. For turbine overspeed, condenser vacuum, etc., in addition to electronic interlock (with sufficient hardware/software redundancy), mechanical interlocks are provided so that the equipment is saved. Choke and kill in offshore is also an example of this. Regulations To meet the requirement of a regulatory board or company standards, measures are taken to enhance overall safety. Incorporation of these safety measures does not always mean that risk is adequately reduced. These measures could make the system acceptable for use, and a local regulatory board may require additional precautions. An example will elaborate the situation. Many turbine manufacturers give low forward power relays or reverse power... [Pg.176]

As discussed earlier the ESD system normally operates in a normally energized condition. Therefore initiating Pb, limit switch contacts, etc. shall be a normally open (NO) contact, but a few contacts such as contact from the motor control center (MOO), overspeed, reset/stop push button, etc. are normally closed (NC)-type contacts (refer Fig. VIII/4.1.4-1). [Pg.611]


See other pages where Overspeed system is mentioned: [Pg.127]    [Pg.319]    [Pg.344]    [Pg.127]    [Pg.319]    [Pg.344]    [Pg.2531]    [Pg.160]    [Pg.557]    [Pg.184]    [Pg.185]    [Pg.185]    [Pg.186]    [Pg.405]    [Pg.83]    [Pg.730]    [Pg.282]    [Pg.179]    [Pg.170]    [Pg.2286]    [Pg.2535]    [Pg.53]    [Pg.83]    [Pg.1113]    [Pg.100]    [Pg.370]    [Pg.35]    [Pg.281]    [Pg.31]    [Pg.198]    [Pg.92]    [Pg.326]    [Pg.885]    [Pg.124]   
See also in sourсe #XX -- [ Pg.317 , Pg.319 ]




SEARCH



Overspeed

© 2026 chempedia.info