Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

OUTPUT SELECT

This circuit is also simulated in Section 6.F.I. We would like to sweep VS from -15 volts to +15 volts and plot the output. Select PSpice and then New Simulation Profile from the Capture menus, select a name for the profile, and then click the Create button. Select the DC Sweep Analysis type and fill in the dialog box as shown ... [Pg.215]

A summary screen which includes the input and output values for the basic parameters is presented to the user as one of the output selections. In this summary screen a graphical representation of the temperature and conversion profiles along the reactor for each bed is presented to give the user an initial look at these values before going to the detailed individual values for each variable (Figure 6.32). [Pg.436]

Table 14-5. Calculation Results for Different Output Selections... Table 14-5. Calculation Results for Different Output Selections...
The selection set is a presentation of the items from which the user makes choices. The elements in the selection set correspond to the elements of a specific activity output. Selection sets may have written letters, words and sentences, symbols used to represent ideas, computer icons, or line draw-ings/pictures. They may be presented in visual (e.g., letters on keys), tactile (e.g., Braille), or auditory (e.g., voice synthesis) form. We can define two selection methods through which the user makes selections using the control interface direct selection and indirect selection (Cook and Hussey, 2(X)2). For any particular application, the three elements of the human-technology interface will be chosen based on the best match to the consumer s skills (motor, sensory, linguistic, and cognitive) (Cook and Hussey, 2002). [Pg.787]

Input Architectural attribute values. Output Selected architecture. [Pg.28]

Control Structure Selection for open loop unstable processes is the main theme of this paper. Hankel singular value has been used as a controllability measure for input-output selection. This method ensures feedback stability of the process with minimal control effort as well as it provides a quantitative justification for the controllability. Simulation results with Tennesse-Eastman test-bed problem justify the proposed theory. [Pg.383]

Management of functional safety Incorporation of our SLCM into the FSMplan, i.e. SLCM is part of the FSM plan. Our SLCM also supports definition of inputs and outputs, selection of failure avoidance measures, and selection of the documentation approaches... [Pg.142]

The concept of molecular dissimilarity is introduced, and shown to be a powerful complement to the well-established notion of molecular similarity. It provides a quantitative assessment of structural variation and diversity. Apphcations within chemical information systems are discussed. These include ranking of search output, selection of representative sets of structures, file screening, data analysis, and creativity stimulation. [Pg.383]

The OUTPUT.SELECT process in the Enabler block must produce a default output value for all states except one. Hence, the simple logic has benefited only sligh% m optimization. The circuit changes have involved the removal of redundant and duplicated logic, which has naturaUy resulted in a reduction in die circuit s delay. The initial size of die circuit has... [Pg.246]

Circuit SEQUENCE-BEHAVIOUR OUTPUT SELECT STATE SELECT... [Pg.246]

Table 7.3 Truth table for the output assignments in the OUTPUT SELECT process of the Decoder component. Table 7.3 Truth table for the output assignments in the OUTPUT SELECT process of the Decoder component.
Step 4 Train the network Select suitable network architecture by setting the number of network inputs equal to the number of input variables and the number of network outputs equal to that of problem output. Select the number of hidden layers and the number of neurons in each hidden layer. [Pg.246]

Selected sensor systems are moved over long cracks of different widths. The output signals are pre-calculated by using eq.(6). Measured and pre-calculated data are compared in 4.2.3.. [Pg.369]

The source of radiation is a linear accelerator with selectable primary energies of 6, 9 or 11 MeV ( VARIAN Linatron 3000 A). The output of the LINAC at 9 MV is 3000 rad ( 30 Gy) per minute. The pulse length is 3.8 microseconds with repetition frequencies between 50 and 250 Hertz. [Pg.584]

The connection table of the query object (similarity probe) is processed to obtain the set of atom pairs, and then the database file is scanned to evaluate the similarity between the query and each of the database structures. The maximum number of structures that the program will select is specified, as well as the minimum similarity score that a database compoimd must show to be selected. Within these limits, the program will select from the database the structures that are most similar (with the highest similarity value) to the query and will create an output file of compoimd numbers and similarity values, sorted by decreasing similarity, for the selected compounds. [Pg.312]

And last not least, we will have to see further improvements in the graphical user interfaces of software systems and the retrieval systems of databases in order to make software and databases more acceptable to the chemical community at large. Software and databases should speak the language a chemist is used to, with hand-drawn chemical structures and reaction equations, or even imderstand the spoken word - and only provide the desired information selectively, not buried in a phe of unnecessary output. [Pg.625]

Let us look at the Mathcad output for a Huckel matrix in more detail. We select the matrix for ethylene to preserve simplicity. [Pg.208]

Combinatorial Hbraries are limited by the number of sequences that can be synthesized. For example, a Hbrary consisting of one molecule each of a 60-nucleotide sequence randomized at each position, would have a mass of >10 g, weU beyond the capacity for synthesis and manipulation. Thus, even if nucleotide addition is random at all the steps during synthesis of the oligonucleotide only a minority of the sequences can be present in the output from a laboratory-scale chemical DNA synthesis reaction. In analyzing these random but incomplete Hbraries, the protocol is efficient enough to allow selection of aptamers of lowest dissociation constants (K ) from the mixture after a small number of repetitive selection and amplification cycles. Once a smaller population of oligonucleotides is amplified, the aptamer sequences can be used as the basis for constmcting a less complex Hbrary for further selection. [Pg.236]


See other pages where OUTPUT SELECT is mentioned: [Pg.253]    [Pg.69]    [Pg.436]    [Pg.226]    [Pg.29]    [Pg.223]    [Pg.99]    [Pg.229]    [Pg.230]    [Pg.243]    [Pg.246]    [Pg.248]    [Pg.253]    [Pg.69]    [Pg.436]    [Pg.226]    [Pg.29]    [Pg.223]    [Pg.99]    [Pg.229]    [Pg.230]    [Pg.243]    [Pg.246]    [Pg.248]    [Pg.390]    [Pg.1424]    [Pg.1971]    [Pg.1990]    [Pg.3001]    [Pg.3029]    [Pg.43]    [Pg.441]    [Pg.500]    [Pg.530]    [Pg.217]    [Pg.118]    [Pg.158]    [Pg.306]    [Pg.315]    [Pg.375]    [Pg.122]    [Pg.258]    [Pg.266]    [Pg.401]    [Pg.112]   
See also in sourсe #XX -- [ Pg.229 , Pg.230 ]




SEARCH



Initial Input-output Variable Selection

SELECT Output Closure

Selection of Controlled (Output) Variables

© 2024 chempedia.info