Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Other Relevant Data

NB Other relevant data taken into consideration in making the overall evaluation) Eormaldehyde [50-00-0] (Vol. 62 1995)... [Pg.98]

The bottle should be clean and dry a little of the stock solution is introduced, the bottle well rinsed with this solution, drained, the remainder of the solution poured in, and the bottle immediately stoppered. If the bottle is not dry, but has recently been thoroughly rinsed with distilled water, it may be rinsed successively with three small portions of the solution and drained well after each rinsing this procedure is, however, less satisfactory than that employing a clean and dry vessel. Immediately after the solution has been transferred to the stock bottle, it should be labelled with (1) the name of the solution (2) its concentration (3) the data of preparation and (4) the initials of the person who prepared the solution, together with any other relevant data. Unless the bottle is completely filled, internal evaporation and condensation will cause drops of water to form on the upper part of the inside of the vessel. For this reason, the bottle must be thoroughly shaken before removing the stopper. [Pg.108]

Stress-strain curves at the conditions of product application. If applicable, this would usually indicate the toughness of material by sizing up the area under the curve (Chapter 2). It would also show the proportional limit, yield point, corresponding elongations, and other relevant data. [Pg.19]

The e-records rule uses many terms that must be understood to grasp fully the intent of the rule. FDA defines electronic records as any combination of text, graphics, data, audio, pictorial, or other information presented in digital form that is created, modified, maintained, archived, retrieved, or distributed by a computer system . A printout of a computer file is not the actual electronic record itself Electronic records include other relevant data, such as which user made a change, the time and date that the change was made, etc. [Pg.1078]

Based on patient-specific data, local resistance patterns, and other relevant data, design an appropriate empirical antimicrobial regimen directed at the most likely pathogens empirical regimens should consist of high-dose intravenous cidal therapy. [Pg.1046]

In between these two extremes, the effective hydrodynamic boundary layer depends on the combined effects of particle size and hydrodynamics. Talking about borderline particle sizes is meaningful only if all other relevant data, such as the fluid viscosity,... [Pg.149]

More experimental data where the secondary KIE was larger than the EIE were subsequently published by Subramanian and Saunders (1984). The 2-arylethyl system was employed in these studies because other relevant data, such as the primary deuterium KIE, were available for this reaction. Special techniques were developed to determine the primary and the secondary tritium KIEs for this system. Three isotopically distinct elimination reactions (49-51) are possible for a 2-arylethyl derivative tracer labelled with tritium at the 2-position. [Pg.218]

Each monograph reviews all pertinent epidemiological studies and cancer bioassays in experimental animals. Mechanistic and other relevant data are also reviewed. With regard to epidemiological studies, cancer bioassays, and mechanistic and other relevant data, only reports that have been published or accepted for publication in the openly available scientific literature are reviewed. Data from government agency reports that are publicly available are also considered. [Pg.67]

We are indebted to Dr. D. Snelling for the performance measurements of current voltage and power shown in Figure U, and for other relevant data. [Pg.252]

The nature of the bond between the molecules of the water-reducing admixture and the surface of the cement constituent hydrates has been described as ionic group outwards in many references [33, 42,], mainly based on work [33, 43] showing migration of cement particles under the influence of an electric current when lignosulfonate molecules are adsorbed on the surface. Similar results have been reported for hydroxycarboxylic acids [44], Other relevant data are summarized below ... [Pg.49]

The location of the pulse input is identified as x = 0. The measured tracer concentrations and other relevant data are given in Figure E6.14.1. From this data, determine the and T parameters on the day of the test for the reach from x = 8,000 m to X = 35,000 m. [Pg.169]

Other relevant data taken into consideration... [Pg.529]

There are several approaches to establish the DL. Visual evaluation may be used for noninstrumental (e.g., solution color) and instrumental methods. In this case, the DL is determined by the analysis of a series of samples with known concentrations and establishing the minimum level at which the analyte can be reliably detected. Presentation of relevant chromatograms or other relevant data is sufficient for justification of the DL. [Pg.733]


See other pages where Other Relevant Data is mentioned: [Pg.156]    [Pg.757]    [Pg.207]    [Pg.446]    [Pg.176]    [Pg.177]    [Pg.177]    [Pg.148]    [Pg.26]    [Pg.26]    [Pg.27]    [Pg.27]    [Pg.122]    [Pg.169]    [Pg.188]    [Pg.216]    [Pg.256]    [Pg.303]    [Pg.335]    [Pg.347]    [Pg.373]    [Pg.397]    [Pg.429]    [Pg.450]    [Pg.466]    [Pg.482]    [Pg.498]    [Pg.522]    [Pg.576]    [Pg.233]    [Pg.26]    [Pg.26]    [Pg.27]   


SEARCH



Data others

RELEVANT DATA

© 2024 chempedia.info