Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Open ends integration

Semi-open formulas are used when the problem exists at only one limit. At the closed end of the integration, the weights from the standard closed-type formulas are used and at the open end, the weights from open formulas are used. (Weights for closed and open formulas of various orders of error may be found in standard numerical methods texts.) Given a closed extended trapezoidal rule of one order higher than the preceding formula, i.e.. [Pg.81]

Some years ago publishers and editors agreed to expand the Handbook by two new open-end volume series Air Pollution and Water Pollution. These broad topics could not be fitted easily into the headings of the first three volumes. All five volume series are integrated through the choice of topics and by a system of cross referencing. [Pg.452]

Why should one go to all this trouble and do all these integrations if there are other, less complex methods available to theorize about ionic solutions The reason is that the correlation function method is open-ended. The equations by which one goes from the gs to properties are not under suspicion. There are no model assumptions in the experimental determination of the g s. This contrasts with the Debye-Htickel theory (limited by the absence of repulsive forces), with Mayer s theory (no misty closure procedures), and even with MD (with its pair potential used as approximations to reality). The correlation function approach can be also used to test any theory in the future because all theories can be made to give g(r) and thereafter, as shown, the properties of ionic solutions. [Pg.325]

The focus of automation is not solely on HPLC anymore (since it is automated), but also includes the sample preparation procedure for drug products since it involves many labor intensive steps (weighing, addition of sample solvent, extraction procedure, mixing, filtration, additional dilutions, second mixing, etc.). So, if the sample preparation procedures are automated and combined with HPLC, then the entire analysis is said to be fully automated whether it is for assay, CU, blend analysis, or even for dissolution testing. Such automated workstations are currently available from number of vendors (Caliper Life Science, SOTAX Inc.), but their ability to integrate with HPLC or UV spectrophotometer is left to the end users. This open-ended option depends on the end user requirements. [Pg.719]

The molecular potential of a quantum molecule in a model SWNT is described here. For simplicity, we assumed a homogeneous cylindrical pore for a model of open-ended SWNT. Thus classical solid-fluid interactions can be calculated using the Lennard-Jones (LJ) potential integrated over an infmitely long cylinder [31] ... [Pg.36]

The difference equation or numerical integration method for vibrational wavefunctions usually referred to as the Numerov-Cooley method [111] has been extended by Dykstra and Malik [116] to an open-ended method for the analytical differentiation of the vibrational Schrodinger equation of a diatomic. This is particularly important for high-order derivatives (i.e., hyperpolarizabilities) where numerical difficulties may limit the use of finite-field treatments. As in Numerov-Cooley, this is a procedure that invokes the Born-Oppenheimer approximation. The accuracy of the results are limited only by the quality of the electronic wavefunction s description of the stretching potential and of the electrical property functions and by the adequacy of the Born-Oppenheimer approximation. [Pg.99]

INTEGRALLY MOUNTED REVERSING STARTER 43 ADJ. TORQUE SW OPENED END CLOSED ENO... [Pg.782]

The quahty of the purified product is an important aspect, and must be ensured because it can influence the potency of dSLIM. Therefore, integrity is tested via exonuclease activity of T7-DNA-polymerase degrading residual DNA molecules with open ends and subsequent gel electrophoresis. Furthermore, the content of endotoxin is determined by an end-point Limulus amoebocyte lysate (LAL) test, and must meet strict standards (< 10 EU mg DNA). [Pg.210]

The oxidation rates of the cubic (3C) [1,3,9,11-15] and hexagonal (6H or 4H) [3,4,16-23] polytypes have been studied. SiC has been oxidised with procedures very similar to those used in Si integrated circuit fabrication. Dry and wet oxidation have been employed in the typical open-ended, resistance-heated quartz tubes, at temperatures ranging from 850 to 1250°C. Since, in general, SiC oxidises at a much slower rate than Si, temperatures in excess of 1000°C are more practical. [Pg.121]


See other pages where Open ends integration is mentioned: [Pg.19]    [Pg.1]    [Pg.141]    [Pg.14]    [Pg.405]    [Pg.220]    [Pg.625]    [Pg.218]    [Pg.203]    [Pg.9]    [Pg.6]    [Pg.62]    [Pg.271]    [Pg.152]    [Pg.220]    [Pg.483]    [Pg.7]    [Pg.136]    [Pg.392]    [Pg.118]    [Pg.100]    [Pg.9]    [Pg.343]    [Pg.204]    [Pg.140]    [Pg.67]    [Pg.414]    [Pg.106]    [Pg.368]    [Pg.462]    [Pg.35]    [Pg.29]    [Pg.41]    [Pg.409]   
See also in sourсe #XX -- [ Pg.8 , Pg.28 ]

See also in sourсe #XX -- [ Pg.8 , Pg.28 ]




SEARCH



Open ends

© 2024 chempedia.info