Normal-phase high pressure liquid chromatography , solvent

In normal high pressure liquid chromatography, typical sample volumes are 20-200 p.L this can become as little as 1 nL in capillary HPLC. Pretreatment of the sample may be necessary in order to protect the stationary phase in the column from deactivation. By employing supercritical fluids such as carbon dioxide, pretreatment can be bypassed in many instances so that whole samples from industrial and environmental matrices can be introduced directly into the column. This is due to the fact that the fluid acts as both extraction solvent and mobile phase. Post-column electrochemistry has been demonstrated. For example, fast-scan cyclic voltammo-grams have been recorded as a function of time after injection of microgram samples of ferrocene and other compounds in dichloromethane solvent and which are eluted with carbon dioxide at pressures of the order of 100 atm and temperatures of 50°C the chromatogram is constructed as a plot of peak current vs. time [18]. [Pg.577]

Isolation of potential anticancer compounds from bioactive extracts involves bioactivity-guided fractionation. The DNA-damaging natural products encountered in our studies were extracted by MEK and/or methanol, and the general methodology which we have employed in our bioassay-directed fractionation of these extracts is schematically presented in Fig. 7. These fractionations involved solvent-solvent partition, Sephadex LH-20 gel filtration, normal phase and reversed-phase (RP) column, preparative thin-layer and high pressure liquid chromatography (HPLC). Silica gel chromatography was employed only if bioactive compounds were found to be stable under these mildly acidic conditions. [Pg.466]

The mass spectrometer is a very sensitive and selective instrument. However, the introduction of the eluent into the vacuum chamber and the resulting significant pressure drop reduces the sensitivity. The gas exhaust power of a normal vacuum pump is some 10 ml min-1 so high capacity or turbo vacuum pumps are usually needed. The gas-phase volume corresponding to 1 ml of liquid is 176 ml for -hexane, 384 ml for ethanol, 429 ml for acetonitrile, 554 ml for methanol, and 1245 ml for water under standard conditions (0°C, 1 atmosphere). The elimination of the mobile phase solvent is therefore important, otherwise the expanding eluent will destroy the vacuum in the detector. Several methods to accomplish this have been developed. The commercialized interfaces are thermo-spray, moving-belt, electrospray ionization, ion-spray, and atmospheric pressure ionization. The influence of the eluent is very complex, and the modification of eluent components and the selection of an interface are therefore important. Micro-liquid chromatography is suitable for this detector, due to its very small flow rate (usually only 10 p min - ). [Pg.22]


See other pages where Normal-phase high pressure liquid chromatography , solvent is mentioned: [Pg.5]    [Pg.25]    [Pg.860]    [Pg.865]    [Pg.275]    [Pg.583]    [Pg.85]    [Pg.609]    [Pg.3207]    [Pg.94]    [Pg.270]    [Pg.64]    [Pg.115]    [Pg.24]    [Pg.5048]    [Pg.256]    [Pg.53]    [Pg.1004]   


SEARCH



Chromatography, high pressure

High Normal phase

High phases

High pressure liquid

High pressure phase

High-pressure liquid chromatography

High-pressure liquid chromatography normal phase

Liquid chromatography, high-pressur

Normal liquids

Normal phase

Normal phase liquid chromatography

Normal pressure

Normal solvent

Normal-Phase Solvents

Normal-phase chromatography

Normal-phase high pressure liquid

Normalized liquid chromatography

Phases chromatography

Phases liquid chromatography

Solvent high pressure

Solvent liquids

Solvent pressures

© 2024 chempedia.info