Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Nitrogen sensitivity

Analytical standards are prepared for two purposes for fortifying control matrices to determine the analytical accuracy and for calibrating the response of the analyte in the nitrogen-sensitive detector. [Pg.363]

Page BD. 1985. Determination of acrylonitrile in foods by headspace-gas chromatography with nitrogen-sensitive detection Collaborative study. J Assoc Off Anal Chem 68 776-782. [Pg.116]

The partial pressure is calculated from the ion flow measured for a certain fragment by multiplication w/ith two factors. The first factor w/ill depend only on the nitrogen sensitivity of the detector and thus is a constant for the device. The second w/ill depend only on the specific ion properties. [Pg.106]

Nitrogen sensitivity (equipment constant) Partial pressure of the gas Ion current for atomic number m... [Pg.108]

Reichert and Linckens [83] have reviewed gas chromatographic methods for the determination of nitriloacetic acid in potable waters. They point out that esterification of the nitriloacetic acid is required to enable it to be volatilised in the gas-liquid chromatographic column, and they compared a range of esterification reagents and conditions for simplicity and speed of operation. The method chosen involved treatment of a concentrated sample with a mixture of -propanol-acctyl chloride (10 1) and the resulting nitroacetic acid-propyl ester injected into a column, which was fitted with a nitrogen-sensitive detector. The detection limit for nitriloacetic acid in potable water is about lpgL-1. [Pg.269]

K.E. McCulloh and R. Tilford, Nitrogen Sensitivities of a Sample of Commercial... [Pg.475]

The product is very oxygen- and nitrogen-sensitive. The synthesis must be carried out under an atmosphere of pure argon (or helium) and the solvents must be argon-flushed before they are used. [Pg.71]

Least et al. reduced the sample size to 20 pi serum, plasma, or saliva, in a microscale procedure. The extraction was carried out with a chloroform-isopropanol solution of the internal standard, 3-isobutyl-l-methylxanthine. After alkylation with tetramethylammonium hydroxide and pentyl iodide, gas chromatography was carried out on a packed 3 OV-17 on Gas Chrom Q column, by temperature programming from 180°C to 260°C, and using a nitrogen sensitive detector. With the sample volume used, the background interference is equivalent to about 0.1 mg/litre, and 0.5 mg theophylline per litre can easily be measured. Between-run... [Pg.205]

Preece NE, Forrow S, Ghatineh S, et al. 1992a. Detennination of hydrazine in biofluids by capillary gas chromatographv with nitrogen-sensitive or mass spectrometric detection. J Chromatogr Biomed Appl 573 227-234. [Pg.171]

Probst, R., Blobner, M., Luppa, P. and Neumeier, D. Quantification of the neuromuscular blocking agent rocuronium and its putative metabolite 17-desacetylrocuronium in heparinized plasma by capillary gas chromatography using nitrogen sensitive detector. J. Chromatogr. B, 702, 111-117 (1997). [Pg.195]

Mathiasson, L., J.A. Jonsson, and L. Karlsson. 1989. Determination of nitrogen compounds by supercritical fluid chromatography using nitrous oxide as the mobile phase and nitrogen-sensitive detection. J. Chromatogr. 467 61-74. [Pg.109]

Fig. 3.12. Capillary chromatograms of volatiles from 24 h urine of a normal male detected by (A) flame ionization detector, and (B) the nitrogen sensitive thermionic detector. Reproduced from [113]. Fig. 3.12. Capillary chromatograms of volatiles from 24 h urine of a normal male detected by (A) flame ionization detector, and (B) the nitrogen sensitive thermionic detector. Reproduced from [113].
GLC Determination of 5-Fluorouracil in Human Plasma with a Nitrogen Sensitive Detector... [Pg.10]

Human Plasma and Urine Using High-Resolution Gas-Liquid Chromatography with Nitrogen-Sensitive Detection... [Pg.13]

Gas Chromatographic Determination of Cocaine in Whole Blood and Plasma Using a Nitrogen-Sensitive Flame Ionization Detector... [Pg.69]

Hucker, H. B., and Stauffer, S. C. Rapid, Sensitive Gas-Liquid Chromatographic Method for Determination of Amitriptyline and Nortriptyline in Plasma Using a Nitrogen-Sensitive Detector... [Pg.117]

Determination of Nitrazepam and Its Main Metabolites in Urine by Gas-Liquid Chromatography Use of Electron Capture and Nitrogen-Sensitive Detectors... [Pg.132]

Gas Chromatographic Micro-Scale Procedure for Theophylline with Use of a Nitrogen-Sensitive Detector Clin. Chem. (Winston-Salem, N. C.) 22(6) 765-768 (1976) CA 85 56434s... [Pg.150]

Nitrogen-Sensitive Gas Chromatographic Detection of Nanogram Levels of Phencyclidine in Whole Blood... [Pg.154]

Micro Method for the Gas Chromatographic Determination of Serum Theophylline Utilizing an Organic Nitrogen Sensitive Detector J. Chromatogr. 143(1) 83-88 (1977) ... [Pg.159]

Diazepam and Desmethyldiazepam Quantitation in Whole Blood by Nitrogen-Sensitive Detector After Derivat-ization... [Pg.172]

GLC Determination of Chlorpheniramine in Human Plasma Using a Nitrogen Sensitive Thermionic Detector Anal. Lett. 10(14) 1163-1173 (1977) ... [Pg.193]

Determination of Therapeutic and Toxic Concentrations of Doxepin and Loxapine Using Gas-Liquid Chromatography with a Nitrogen-Sensitive Detector, and Gas Chromatography-Mass Spectrometry of Loxapine... [Pg.263]


See other pages where Nitrogen sensitivity is mentioned: [Pg.346]    [Pg.56]    [Pg.119]    [Pg.157]    [Pg.377]    [Pg.518]    [Pg.77]    [Pg.191]    [Pg.207]    [Pg.195]    [Pg.84]    [Pg.89]    [Pg.524]    [Pg.198]    [Pg.29]    [Pg.63]    [Pg.117]    [Pg.157]    [Pg.180]    [Pg.291]   
See also in sourсe #XX -- [ Pg.57 ]




SEARCH



© 2024 chempedia.info