Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Multiple reactions method

An alternative approach to peptide sequencing uses a dry method in which the whole sequence is obtained from a mass spectrum, thereby obviating the need for multiple reactions. Mass spec-trometrically, a chain of amino acids breaks down predominantly through cleavage of the amide bonds, similar to the result of chemical hydrolysis. From the mass spectrum, identification of the molecular ion, which gives the total molecular mass, followed by examination of the spectrum for characteristic fragment ions representing successive amino acid residues allows the sequence to be read off in the most favorable cases. [Pg.333]

The second use of Equations (2.36) is to eliminate some of the composition variables from rate expressions. For example, 0i-A(a,b) can be converted to i A a) if Equation (2.36) can be applied to each and every point in the reactor. Reactors for which this is possible are said to preserve local stoichiometry. This does not apply to real reactors if there are internal mixing or separation processes, such as molecular diffusion, that distinguish between types of molecules. Neither does it apply to multiple reactions, although this restriction can be relaxed through use of the reaction coordinate method described in the next section. [Pg.67]

In the past, no snitable analytical methodologies were capable of investigating these multiple reactions and even today, the complete extraction and analysis of all the componnds is still a difficult task. The methods for extraction must be optimized for each sample according to the solubility of either phytylated (chlorophylls and pheophytins) or dephytylated (chlorophyllides and pheophorbides) derivatives, often requiring several repeated steps and the use of a single or a mixture of organic solvents. [Pg.430]

The method for chloroacetanilide soil metabolites in water determines concentrations of ethanesulfonic acid (ESA) and oxanilic acid (OXA) metabolites of alachlor, acetochlor, and metolachlor in surface water and groundwater samples by direct aqueous injection LC/MS/MS. After injection, compounds are separated by reversed-phase HPLC and introduced into the mass spectrometer with a TurboIonSpray atmospheric pressure ionization (API) interface. Using direct aqueous injection without prior SPE and/or concentration minimizes losses and greatly simplifies the analytical procedure. Standard addition experiments can be used to check for matrix effects. With multiple-reaction monitoring in the negative electrospray ionization mode, LC/MS/MS provides superior specificity and sensitivity compared with conventional liquid chromatography/mass spectrometry (LC/MS) or liquid chromatography/ultraviolet detection (LC/UV), and the need for a confirmatory method is eliminated. In summary,... [Pg.349]

Undoubtedly, the technique most suited to tackle polyatomic multichannel reactions is the crossed molecular beam (CMB) scattering technique with mass spectrometric detection and time-of-flight (TOF) analysis. This technique, based on universal electron-impact (El) ionization coupled with a quadrupole mass filter for mass selection, has been central in the investigation of the dynamics of bimolecular reactions during the past 35 years.1,9-11 El ionization affords, in principle, a universal detection method for all possible reaction products of even a complex reaction exhibiting multiple reaction pathways. Although the technique is not usually able to provide state-resolved information, especially on a polyatomic... [Pg.331]

We will now discuss some very recent applications of the soft El ionization method for product detection in CMB experiments. We will first deal with two polyatomic reactions of ground state oxygen atoms with unsaturated hydrocarbons (acetylene and ethylene) these reactions are characterized by multiple reaction pathways and are of great relevance, besides being from a fundamental point of view, in combustion and atmospheric chemistry. [Pg.348]

Several calculation methods for establishing reaction kinetics from the scanning DSC results are discussed in the literature [91-97]. Kinetic constants can be obtained from scanning DSC tests under favorable circumstances that include (1) the availability of a sample that even in milligram quantities is truly representative of the process material, and (2) kinetics that are uncomplicated by multiple reactions or by the presence of autocatalysis or inhibitor effects. [Pg.58]

As compared with the other closures discussed in this chapter, computation studies based on the presumed conditional PDF are relatively rare in the literature. This is most likely because of the difficulties of deriving and solving conditional moment equations such as (5.399). Nevertheless, for chemical systems that can exhibit multiple reaction branches for the same value of the mixture fraction,162 these methods may offer an attractive alternative to more complex models (such as transported PDF methods). Further research to extend multi-environment conditional PDF models to inhomogeneous flows should thus be pursued. [Pg.255]

GC/MS(/MS) is also popular for quantifying DBFs. Selected ion monitoring (SIM) or multiple reaction monitoring (MRM) mode are used with GC/MS and GC/ MS/MS, respectively, to maximize the sensitivity and provide low detection limits. Some EFA Methods utilize GC/MS, including EFA Method 524.2, which uses GC/ EI-MS for THM analysis [155], and EFA Method 521, which uses for GC/CI-MS/ MS for nitrosamine analysis [55]. In addition, many priority unregulated DBFs have been measured using GC/MS in a U.S. Nationwide Occurrence Study [11,12]. [Pg.121]

Students may have seen the acetaldehyde decomposition reaction system described as an example of the application of the pseudo steady state (PSS), which is usually covered in courses in chemical kinetics. We dealt with this assumption in Chapter 4 (along with the equilibrium step assumption) in the section on approximate methods for handling multiple reaction systems. In this approximation one tries to approximate a set of reactions by a simpler single reaction by invoking the pseudo steady state on suitable intermediate species. [Pg.402]

Based on an in-vial derivatization method, the mass spectra of methylated flavonoids and other phenolics have been obtained via EI-MS at 70 eV. Detection was performed in the selective ion monitoring mode and peaks were identified and quantified using target ions. The detection limits ranged between 2 and 40 ng/ml, whereas the limits of quantitation fall in the range of 5 to 118 ng/ml, with flavonoids accounting for the lowest sensitivity due to their multiple reaction behavior. [Pg.99]

It is a serious but frequently neglected problem that the analysis of the data obtained with the method (2) or (3) above is only straightforward when each molecule undergoes only a one-step reaction upon one adsorption sojourn on the catalyst surface. If several consecutive reactions (e.g., isomerization combined with hydrogenolysis or two isomerization steps in combination) follow each other before the molecules leave the surface, useful information is still gained (167, 168), but the discussion of data is more complicated. Metals like Pt or Pd do not seem to be a problem in this respect, as is the case with other metals at the lowest possible reaction temperatures. However, metals like Ir or Rh are apparently very active in performing several consecutive steps during one residence of the molecules on the surface, and at temperatures above 200°C it is difficult to avoid the multiple reactions (167). [Pg.165]

Fig. 4.7.2 Multiple reaction monitoring (MRM) chromatogram of pooled urine spiked with C7-polyols produced by method 1 (without separation of polyol isomers). MRM transitions are given for each mass transition. IS Internal standard... Fig. 4.7.2 Multiple reaction monitoring (MRM) chromatogram of pooled urine spiked with C7-polyols produced by method 1 (without separation of polyol isomers). MRM transitions are given for each mass transition. IS Internal standard...

See other pages where Multiple reactions method is mentioned: [Pg.26]    [Pg.26]    [Pg.1985]    [Pg.298]    [Pg.39]    [Pg.119]    [Pg.246]    [Pg.314]    [Pg.644]    [Pg.378]    [Pg.36]    [Pg.188]    [Pg.347]    [Pg.359]    [Pg.361]    [Pg.497]    [Pg.403]    [Pg.217]    [Pg.805]    [Pg.248]    [Pg.395]    [Pg.235]    [Pg.173]    [Pg.60]    [Pg.544]    [Pg.984]    [Pg.1225]    [Pg.73]    [Pg.984]    [Pg.474]    [Pg.639]    [Pg.49]    [Pg.39]    [Pg.249]   
See also in sourсe #XX -- [ Pg.21 ]




SEARCH



Methods multiple

Multiple reactions

Reaction methods

Reaction multiple reactions

© 2024 chempedia.info