Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mobile supercritical fluids

A separation technique in which the mobile phase is a supercritical fluid. [Pg.596]

The most common mobile phase for supercritical fluid chromatography is CO2. Its low critical temperature, 31 °C, and critical pressure, 72.9 atm, are relatively easy to achieve and maintain. Although supercritical CO2 is a good solvent for nonpolar organics, it is less useful for polar solutes. The addition of an organic modifier, such as methanol, improves the mobile phase s elution strength. Other common mobile phases and their critical temperatures and pressures are listed in Table 12.7. [Pg.596]

Unfortunately, not much experimental work has been carried out on the combination of Supercritical fluid extraction and liquid chromatography systems (43, 44). One of the reasons for this arises from the difficulties in achieving compatibility between the extraction solvent and the FC mobile phase. Baseline perturbations have been... [Pg.141]

D. E. Martire and R. E. Boehm, Unified molecular theory of clrromatography and its application to supercritical fluid mobile phases. 1. Eluid-liquid (absorption) clrromatography , J. Phys. Chem. 91 2433-2446 (1987). [Pg.167]

D. E. Martue, Unified theory of absorption clrromatography gas, liquid and supercritical fluid mobile phases , ]. Liq. Chmmatogr. 10 1569-1588 (1987). [Pg.167]

D. P. Poe and D. E. Marthe, Plate height theory for compressible mobile phase fluids and its application to gas, liquid and supercritical fluid cliromatography , 7. Chromatogr. 517 3-29(1990). [Pg.169]

Figure 12.22 SFC-GC analysis of aromatic fraction of a gasoline fuel, (a) SFC trace (b) GC ttace of the aromatic cut. SFC conditions four columns (4.6 mm i.d.) in series (silica, silver-loaded silica, cation-exchange silica, amino-silica) 50 °C 2850 psi CO2 mobile phase at 2.5 niL/min FID detection. GC conditions methyl silicone column (50 m X 0.2 mm i.d.) injector split ratio, 80 1 injector temperature, 250 °C earner gas helium temperature programmed, — 50 °C (8 min) to 320 °C at a rate of 5 °C/min FID detection. Reprinted from Journal of Liquid Chromatography, 5, P. A. Peaden and M. L. Lee, Supercritical fluid chromatography methods and principles , pp. 179-221, 1987, by courtesy of Marcel Dekker Inc. Figure 12.22 SFC-GC analysis of aromatic fraction of a gasoline fuel, (a) SFC trace (b) GC ttace of the aromatic cut. SFC conditions four columns (4.6 mm i.d.) in series (silica, silver-loaded silica, cation-exchange silica, amino-silica) 50 °C 2850 psi CO2 mobile phase at 2.5 niL/min FID detection. GC conditions methyl silicone column (50 m X 0.2 mm i.d.) injector split ratio, 80 1 injector temperature, 250 °C earner gas helium temperature programmed, — 50 °C (8 min) to 320 °C at a rate of 5 °C/min FID detection. Reprinted from Journal of Liquid Chromatography, 5, P. A. Peaden and M. L. Lee, Supercritical fluid chromatography methods and principles , pp. 179-221, 1987, by courtesy of Marcel Dekker Inc.
The coupling of supercritical fluid extraction (SEE) with gas chromatography (SEE-GC) provides an excellent example of the application of multidimensional chromatography principles to a sample preparation method. In SEE, the analytical matrix is packed into an extraction vessel and a supercritical fluid, usually carbon dioxide, is passed through it. The analyte matrix may be viewed as the stationary phase, while the supercritical fluid can be viewed as the mobile phase. In order to obtain an effective extraction, the solubility of the analyte in the supercritical fluid mobile phase must be considered, along with its affinity to the matrix stationary phase. The effluent from the extraction is then collected and transferred to a gas chromatograph. In his comprehensive text, Taylor provides an excellent description of the principles and applications of SEE (44), while Pawliszyn presents a description of the supercritical fluid as the mobile phase in his development of a kinetic model for the extraction process (45). [Pg.427]

Supercritical fluid chromatography (SFC) refers to the use of mobile phases at temperatures and pressures above the critical point (supercritical) or just below (sub-critical). SFC shows several features that can be advantageous for its application to large-scale separations [132-135]. One of the most interesting properties of this technique is the low viscosity of the solvents used that, combined with high diffusion coefficients for solutes, leads to a higher efficiency and a shorter analysis time than in HPLC. [Pg.12]

The use of both sub- and supercritical fluids as eluents yields mobile phases with increased diffusivity and decreased viscosity relative to liquid eluents [23]. These properties enhance chromatographic efficiency and improve resolution. Higher efficiency in SFC shifts the optimum flowrate to higher values so that analysis time can be reduced without compromising resolution [12]. The low viscosity of the eluent also reduces the pressure-drop across the chromatographic column and facilitates the... [Pg.301]

The dense fluid that exists above the critical temperature and pressure of a substance is called a supercritical fluid. It may be so dense that, although it is formally a gas, it is as dense as a liquid phase and can act as a solvent for liquids and solids. Supercritical carbon dioxide, for instance, can dissolve organic compounds. It is used to remove caffeine from coffee beans, to separate drugs from biological fluids for later analysis, and to extract perfumes from flowers and phytochemicals from herbs. The use of supercritical carbon dioxide avoids contamination with potentially harmful solvents and allows rapid extraction on account of the high mobility of the molecules through the fluid. Supercritical hydrocarbons are used to dissolve coal and separate it from ash, and they have been proposed for extracting oil from oil-rich tar sands. [Pg.440]

Chromatography is a physical method of separation in which the components to be separated are distributed between two phases, one of which is stationary (the stationary phase), while the other (the mobile phase) moves in a definite direction. A mobile phase is described as a fluid which percolates through or along the stationary bed in a definite direction . It may be a liquid, a gas or a supercritical fluid, while the stationary phase may be a solid, a gel or a liquid. If a liquid, it may be distributed on a solid, which may or may not contribute to the separation process. ... [Pg.24]

Supercritical fluid chromatography (SEC) was first reported in 1962, and applications of the technique rapidly increased following the introduction of commercially available instrumentation in the early 1980s due to the ability to determine thermally labile compounds using detection systems more commonly employed with GC. However, few applications of SEC have been published with regard to the determination of triazines. Recently, a chemiluminescence nitrogen detector was used with packed-column SEC and a methanol-modified CO2 mobile phase for the determination of atrazine, simazine, and propazine. Pressure and mobile phase gradients were used to demonstrate the efficacy of fhe fechnique. [Pg.442]

In SFC the same type of supercritical fluid (i.e. a fluid above its critical temperature and critical pressure) is used as the mobile phase to chromatograph additives... [Pg.205]


See other pages where Mobile supercritical fluids is mentioned: [Pg.596]    [Pg.597]    [Pg.779]    [Pg.201]    [Pg.546]    [Pg.226]    [Pg.105]    [Pg.111]    [Pg.1]    [Pg.136]    [Pg.141]    [Pg.147]    [Pg.152]    [Pg.324]    [Pg.301]    [Pg.302]    [Pg.89]    [Pg.6]    [Pg.307]    [Pg.316]    [Pg.316]    [Pg.324]    [Pg.410]    [Pg.486]    [Pg.503]    [Pg.817]    [Pg.821]    [Pg.829]    [Pg.829]    [Pg.833]    [Pg.834]    [Pg.1007]    [Pg.1009]    [Pg.210]   
See also in sourсe #XX -- [ Pg.301 ]

See also in sourсe #XX -- [ Pg.301 ]




SEARCH



Mobile phase in supercritical fluid

Mobile phases for supercritical fluid chromatography

Supercritical Fluids as Mobile Phases

Supercritical fluid chromatography mobile phase conditions

Supercritical fluid chromatography mobile phase selection

Supercritical fluid mobile phases

Supercritical fluid mobile phases characteristics

Supercritical fluid technology mobility

© 2024 chempedia.info