Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Manual alignment

Structural studies of PepTl substrates were extended using comparative molecular field analysis (CoMFA) of 10 known substrates for the peptide transporter with data derived from an in situ rat model (222). The CoMFA approach required manual alignment of relatively rigid molecules however, it allowed explanation of the variation in the permeability with respect to steric and electrostatic interaction energies of the molecules (222). This 3D-QSAR produced by our laboratory provided a valuable starting point for future prediction of... [Pg.276]

The fabrication procedure for the parylene electro spray tip is relatively simple, but manual alignment of the parylene tip to the end of the microchannel is tedious and should be replaced by a structure with mechanical alignment features. Because the thermal parameters of parylene are different from those of the cyclo-olefin polymer substrate, good control of the thermal bonding conditions is required for proper sealing between two materials without collapsing of the microchannels. [Pg.134]

Hydrated peptide-lipid mixtures can be manually aligned between two parallel, flat surfaces. The procedures are described in references 5 and 6. For OCD and neutron diffraction experiments, we used two silica plates. For X-ray diffraction experiments, we used a polished beryllium (Be) plate and a silica plate. The sample thickness (1-80 fxm) was controlled by a spacer between two plates. A circular hole was made in the spacer to provide a cavity to hold the sample. The thicker the sample, the smaller the area of monodomain region will be. The desirable radius of the cavity is about 8 mm for thick ( 80-pm) samples. A sample was aligned between two plates by hand using the procedure of shearing and compression-dilation first described in reference 5. [Pg.91]

For these tests, the optical components were mounted on tripods and located on either end of one of the regenerators. The beam was manually aligned and the absorption peak locations were manually controlled. The path length through the regenerator was 18.3 m (60 feet). [Pg.324]

The first TiiSapphire lasers needed some fine-tuning to obtain stable pulses, especially when the wavelength was changed. The pulse stability had to be checked by a photodiode and the pulse width by an autocorrelator. For the past few years, computer controlled self-adjusting Ti Sapphire lasers have been available. These lasers do not need manual alignment. [Pg.266]

A typical alignment procedure involves the application of a program such as CLUSTAL W, followed by manual alignment editing and submission to a treebuilding program. This procedure should be performed with the following questions and considerations in mind ... [Pg.329]

Boon et al. also studied several chiral molecules, which included again two amino acids (Ala and Leu) and CHFClBr, a prototype of chiral molecules. Ab initio total molecular electron densities yielded both Euclidean distances and Carbo indices between the enantiomers of these molecules. Molecular superposition was performed with, on the one hand, a manual alignment based on chemical intuition and the QSSA method, on the other hand. When analyzing the tables of the work by Boon et al. and comparing the results to the work by Mezey et al., similar values for the Euclidean distances between the two enantiomers appear for Ala and Leu, which once again illustrates the power of the ASA promolecular densities to yield quantum similarity measures in good agreement with those obtained from ab initio calculations. [Pg.178]

Fig. 1. Sequence alignment and phylogenetic relationship of CXC chemokines. The alignment was generated with the program Megalign (DNA Star) using the Clustal method and then manually aligned to obtain the maximum amino acid similarity. Amino acid residues conserved in all sequences are boxed and shaded. Unshaded boxed regions indicate amino acid residues conserved in at least four chemokines. Fig. 1. Sequence alignment and phylogenetic relationship of CXC chemokines. The alignment was generated with the program Megalign (DNA Star) using the Clustal method and then manually aligned to obtain the maximum amino acid similarity. Amino acid residues conserved in all sequences are boxed and shaded. Unshaded boxed regions indicate amino acid residues conserved in at least four chemokines.
Most sequence alignment methods are automated, but some are performed manually. Both the automated and the manual alignment of multiple chains is a challenging problem because of the myriad of alignment possibilities. The number of combinations for alignment is determined by raising the number of sequences by the number of amino acid residues of the longest sequence (Equation [1]). [Pg.86]

Results of POY analysis are especially interesting for comparison because they are produced without the subjective stage of manual aligning. The details of POY analysis are described in Gardiner et al. (2005). [Pg.182]

Registration holes (manual alignments or vision systems)... [Pg.909]


See other pages where Manual alignment is mentioned: [Pg.188]    [Pg.133]    [Pg.597]    [Pg.483]    [Pg.134]    [Pg.849]    [Pg.1280]    [Pg.301]    [Pg.184]    [Pg.92]    [Pg.593]    [Pg.520]    [Pg.421]    [Pg.147]    [Pg.256]    [Pg.247]    [Pg.92]    [Pg.473]    [Pg.600]    [Pg.319]    [Pg.72]    [Pg.73]    [Pg.329]    [Pg.169]    [Pg.290]    [Pg.515]    [Pg.320]    [Pg.623]    [Pg.166]    [Pg.149]    [Pg.149]    [Pg.150]    [Pg.152]    [Pg.182]    [Pg.185]    [Pg.187]    [Pg.3]    [Pg.1138]    [Pg.242]   
See also in sourсe #XX -- [ Pg.150 , Pg.151 , Pg.160 ]




SEARCH



© 2024 chempedia.info