Loop detection

Deluge systems should generally be activated by automatic means. Activation by manual means defeats the objective of installing a deluge system, and fire water monitors should be provided instead as they are more cost effective where manual means is relied upon. Most systems provided at petroleum facilities are typically activated by a heat detection. Usually a fusible plug pneumatic loop detection system or UV/IR detectors are placed around the equipment. This insures activation when operators are not present and only when a real fire situation is present. [Pg.210]

For high-throughput data collection, sample centring via loop detection is currently the method of choice for placing crystals in the X-ray beam. Alternative methods rely on the direct detection of the crystal itself by monitoring the intensity of either X-ray diffraction from the crystal or X-ray fluorescence from an element in the crystal that is not present in the cryoprotectant (Pohl et al., 2004). Both of these approaches have drawbacks. First, some of the limited X-ray lifetime of the crystal (Section 12.6) must be committed to detection instead of data collection. Second, the loop itself has to be placed close to the X-ray beam prior to crystal detection, followed by step-wise translation of the crystal through the beam, thereby increasing the time required to centre the sample. [Pg.179]

Ion 200pL loop Detection limit (pg L ) Concentrator column ... [Pg.51]

In a feedback configuration the controlled variable (temperature) has to be upset before correction can take place. Feedforward is a mode of control that corrects for a disturbance before it can cause an upset. Figure 2.108 illustrates feedforward control of a steam heater. The feedforward portion of the loop detects the major load variables (the flow and temperature of the entering process fluid) and calculates the required steam flow (Ws) as a function of these variables. When the process flow increases, it is matched with an equal increase in the steam flow controller set point. Because instantaneous response is not possible, dynamic correction by a lead-lag element is provided. [Pg.283]

Include all human-in-the-loop detection options and responses, such as visual or clinical detection and the corresponding responses. [Pg.33]

Enhanced (up to 20 times baseline) polymer erosion and drug release were observed when bioerodible samples were exposed to ultrasound. The system s response to the ultrasonic triggering was also rapid (within 2 min) and reversible. This was determined by an on-line UV spectrophotometric response in a closed-loop detection system where the concentration of the releasing agent was continuously monitored (42). [Pg.20]

The three major types of process heater cascade control systems are shown in Figures 10-2, 10-3, and 10-4. Each system has a primary and a secondary loop. The secondeiry loop detects and acts on as many upsets as possible so that the primary loop has the least disturbances. [Pg.335]

Adaptive optics The real-time correction of atmospheric distortion through closed-loop detection and warping of an optical surface in a telescope system in a manner opposite to that produced by turbulence. [Pg.206]

Figure Bl.19.39. Schematic of the themiocoiiple probe in a scaiming themial profiler. The probe is supported on a piezoelectric element for modulation of tip-sample distance at frequency oi and to provide positioning. The AC thennal signal at oi is detected, rectified, and sent to the feedback loop, which supplies a voltage to the piezostack to maintain the average tip-sample spacing constant. (Taken from [209], figure 1.)... Figure Bl.19.39. Schematic of the themiocoiiple probe in a scaiming themial profiler. The probe is supported on a piezoelectric element for modulation of tip-sample distance at frequency oi and to provide positioning. The AC thennal signal at oi is detected, rectified, and sent to the feedback loop, which supplies a voltage to the piezostack to maintain the average tip-sample spacing constant. (Taken from [209], figure 1.)...
After an initial starting geometry has been generated and optimized (e.g., in a force field), the new conformation is compared with all the previously generated conformations, which are usually stored as a list of unique conformations. If a substantially different geometry is detected it is added to the list otherwise, it is rejected. Then a new initial structure is generated for the next iteration. Finally, a preset stop criterion, e.g., that a given number of loops has been performed or that no new conformations can be found, terminates the procedure. [Pg.105]

It was noted earlier (p. 115) that the upward swing in the Type IV isotherm characteristic of capillary condensation not infrequently commences in the region prior to the lower closure point of the hysteresis loop. This feature can be detected by means of an a,-plot or a comparison plot (p. 100). Thus Fig. 3.25(a) shows the nitrogen isotherm and Fig. 3.25(h) the a,-plot for a particular silica gel the isotherm is clearly of Type IV and the closure point is situated around 0 4p° the a,-plot shows an upward swing commencing at a = 0-73, corresponding to relative pressures of 013 and therefore well below the closure point. [Pg.160]

Engines are also designed to use either gasoline or methanol and any mixture thereof (132—136). Such a system utilizes the same fuel storage system, and is called a flexible fueled vehicle (EEV). The closed loop oxygen sensor and TWC catalyst system is perfect for the flexible fueled vehicle. Optimal emissions control requires a fuel sensor to detect the ratio of each fuel being metered at any time and to correct total fuel flow. [Pg.493]

Data should be available at every phase of the service quality loop from soliciting business through client reaction and feedback. The collection and analysis of data is a means of improving the service or conversely can detect the onset of an insidious degradation of the service before it becomes a major issue. [Pg.197]

These are locations where condensation can accumulate. If allowed to accumulate, at some time it will enter the compressor as a slug of liquid and cause damage. If the piping configuration must contain a loop, the lower portion of the loop should be instrumented to detect the presence of liquid accumulation. Both for the drums and for the piping loops, pro vision must be made to drain any liquid that may be present. [Pg.472]

A six-port valve was first used to interface the SEC microcolumn to the CZE capillary in a valve-loop design. UV-VIS detection was employed in this experiment. The overall run time was 2 h, with the CZE runs requiring 9 min. As in the reverse phase HPLC-CZE technique, runs were overlapped in the second dimension to reduce the apparent run time. The main disadvantage of this yu-SEC-CZE method was the valve that was used for interfacing. The six-port valve contributed a substantial extracolumn volume, and required a fixed volume of 900 nL of effluent from the chromatographic column for each CZE run. The large fixed volume imposed restrictions on the operating conditions of both of the separation methods. Specifically, to fill the 900 nL volume, the SEC flow rate had to be far above the optimum level and therefore the SEC efficiency was decreased (22). [Pg.206]


See other pages where Loop detection is mentioned: [Pg.112]    [Pg.722]    [Pg.747]    [Pg.19]    [Pg.327]    [Pg.216]    [Pg.112]    [Pg.722]    [Pg.747]    [Pg.19]    [Pg.327]    [Pg.216]    [Pg.1699]    [Pg.1716]    [Pg.1895]    [Pg.3001]    [Pg.10]    [Pg.376]    [Pg.10]    [Pg.10]    [Pg.260]    [Pg.57]    [Pg.198]    [Pg.484]    [Pg.670]    [Pg.681]    [Pg.684]    [Pg.687]    [Pg.696]    [Pg.730]    [Pg.734]    [Pg.391]    [Pg.449]    [Pg.515]    [Pg.233]    [Pg.238]    [Pg.265]    [Pg.280]    [Pg.306]    [Pg.306]   
See also in sourсe #XX -- [ Pg.19 ]