Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Loading device

Its speed is reasonably acceptable for suitable loading devices. [Pg.2520]

Provide unique loading devices See also Chapter 6... [Pg.33]

When it is not possible to conduct any of the above three methods, the test motor may be loaded onto an uncalibrated generator or any other loading device. [Pg.256]

Compression-molded devices of poly(N-palmitoyl hydroxyproline ester) (side chain length 16 carbons), poly(N-decanoylhydroxy-proline ester) (side chain length 10 carbons), and poly(JN-hexanoyl-hydrox roline ester) (side chain length 6 carbons) were prepared with dye contents of 1,5,10, and 20% of either -nitroaniline or acid orange. Release curves were obtained by placing the loaded devices into phospate buffer (pH 7.4) at 37 C. The amount of released dye was followed spectrophotometrically in the usual fashion. [Pg.207]

Diameter of Disc Average thickness Device volume Device weight Dye loading Device Composition... [Pg.177]

Mechanical loading devices to load the tyre into the mould cavity. [Pg.204]

Rupture Disc and Spring Loaded Relief. Normal Relief May Co Through Spring Loaded Device/ and Rupture Disc Is Back-up for Larger Reliefs. [Pg.369]

The prepared sample may be applied in pH 2.2 buffer directly to the top of the column and the analysis sequence started, and after elution of all the amino acids and regeneration of the resin column, the next sample can be applied. However, many newer models incorporate an automatic loading device which enables several samples to be stored ready for analysis either in sample cups or in small Teflon coils. After the completion of an analysis the next stored sample is automatically applied to the resin and the buffer cycle restarted. [Pg.377]

A loading device such as a spring is needed to ensure that in the event of loss or hydraulic pressure the sealing surfaces are kept closed. The amount of the load on the seahng area is determined by the... [Pg.63]

Fig. 4.3.18. Diagram of loading device in DURIMET hardness tester manufactured by Ernst Leitz GmbH, Wetzlar. Fig. 4.3.18. Diagram of loading device in DURIMET hardness tester manufactured by Ernst Leitz GmbH, Wetzlar.
Another vacuum electrochemical cell, shown in Figure 18.14, incorporates both an internal alumina drying column [37] and also a specialized sample loading device [43]. This sample loading device is extremely advantageous, because air-sensitive solids can be directly added to the solvent-electrolyte solution after it has been superdried. The cell is used in the following manner The vacuum electrochemical cell parts are cleaned, washed with solvent, and dried in a... [Pg.560]

Figure 18.14 Vacuum electrochemical cell with upper and lower halves, electrodes, sample loading device, solvent introduction port, and alumina column. [From Ref. 37, with permission.]... Figure 18.14 Vacuum electrochemical cell with upper and lower halves, electrodes, sample loading device, solvent introduction port, and alumina column. [From Ref. 37, with permission.]...
We also devised a system that uses acid/base control of expansion and contraction of the capsules and their guests. A number of studies with the cylindrical capsule defined its application as a reaction vessel [77,78] but the conformational flexibility [79] of normal alkanes as guests (which adopt shapes complementary to their hosts) offered an opportunity to create what we termed a spring-loaded device. [Pg.72]

Ladedichte = loading density 206 Ladeschlauch = plastic hose as loading device for permitted explosives Ladestock = tamping pole 308 Lager = magazine 44 138 209 299 Lambrex = slurry (Austria) 194... [Pg.32]

The powder form explosives are cartridged and inserted in plastic hoses as a loading device. [Pg.434]

The main novelties introduced in the DCB testing concern a) the loading device, b) the specimen geometry, c) the measurement scheme, and d) the determination of Gic and the bridging law from experimental data. [Pg.515]

Two extensometers, one attached to the test jig of the loading device for measuring the crack opening along the load line and another attached to the top and bottom sides of the specimen at the end of the initial crack, were used. The displacement of the actuator of the testing machine was also recorded. [Pg.518]

A comb-like loading device was used and can be recommended for applying high tensile loads directly to crack faces... [Pg.524]

CONFIG. SYS Loads device drivers and uses the information from the AUTOEXEC. BAT to configure the system environment. Memory management tools and DOS peripheral drivers can be added here. [Pg.557]

C Noimal startup - load all device drivers and software C Dia ostic startup - interactively load device drivers and software... [Pg.791]


See other pages where Loading device is mentioned: [Pg.458]    [Pg.941]    [Pg.487]    [Pg.503]    [Pg.445]    [Pg.445]    [Pg.908]    [Pg.363]    [Pg.234]    [Pg.68]    [Pg.133]    [Pg.213]    [Pg.607]    [Pg.32]    [Pg.103]    [Pg.47]    [Pg.562]    [Pg.564]    [Pg.396]    [Pg.316]    [Pg.302]    [Pg.43]    [Pg.764]    [Pg.607]    [Pg.908]    [Pg.516]    [Pg.517]    [Pg.517]    [Pg.390]    [Pg.559]   
See also in sourсe #XX -- [ Pg.53 , Pg.64 ]




SEARCH



© 2024 chempedia.info