Linear polarization measurements

At pHs5.6, both UDI and PVI-1 cast films produce passivation, UDI reducing the anodic currents by an order of magnitude more than PVI-1. Linear polarization measurements on Cu in UDI solution (pHs5.6) indicate that UDI may have practical application as a corrosion inhibitor for copper. [Pg.250]

The measurements discussed above describe the effects of the BTA, PVI-1, and UDI on the electrochemical processes. believed to be Involved in Cu corrosion at relatively high overpotentials. Open-circuit potential and linear polarization measurements were made in UDI solutions in order to correlate the high overpotential measurements to practical corrosion potentials. [Pg.263]

Mansfeld has described a method to determine Tafel slopes from the nonlinearity found in small magnitude linear polarization measurements [15]. The approach is similar to the fitting method described earlier for fitting potentiodynamic polarization curves to the Wagner-Traud equation, Eq. (3). Mansfeld showed that the fit can be made with only two parameters, the Tafel slopes, instead of four. The values of Ecorr and Ep can be determined, and icon- can be eliminated from Eq. (3) by insertion of Eq. (4)... [Pg.702]

The techniques used for monitoring corrosion in a process plant are (i) visual inspection (ii) weight loss coupons (iii) electrical resistance probes (iv) measurement of corrosion potential (v) linear polarization measurement (vi) hydrogen probes (vii) thickness measurement and crack detection (viii) visual inspection (ix) sentinel holes. [Pg.299]

Linear polarization measurements are executed rapidly. The currents in linear polarization measurements are measured in the potential range between 10 and 20 mV from the equilibrium potential. The E-I dependence in this potential range follows a linear relationship. The slope of the plot, dE/ di, represents the polarization resistance. The corrosion current is calculated using the Stem-Geary equation for known values of the anodic and cathodic Tafel slopes. The ratio of the overpotential to the current represents the resistance in Ohm s law and is often termed the charge transfer resistance or the polarization resistance, Rp. [Pg.24]

F. Mansfeld, Some errors in linear polarization measurements and their correction. Corrosion 30 (1974) 92-96. [Pg.235]

R.H. Hausler, Practical experiences with linear polarization measurements. Corrosion 33 (1977) 117-128. [Pg.235]

Linear polarization measurements are performed by scanning a range close to the corrosion potential. These experiments provide nondestructive information about the corrosion process occurring on reinforcing steel. The polarization resistance (Rp) of a corroding system under activation control is defined as ... [Pg.530]

After eleaning and removal of corrosion products the samples are weighed (both before and after exposure). During a test lasting six hours, linear polarization measurements are carried out after two and four hours. At the end of the test, the samples are polarized stepwise in the cathodic and anodic directions, and the current at the various potential steps is recorded. [Pg.234]

In the previous method and interpretation resistivity measurement is used along side linear polarization measurements (see Section 4.12), not as a stand alone technique. [Pg.68]

Epoxy coated rebars present particular problems to determining the corrosion condition of the Steel. In the first place the bars are electrically isolated from the concrete except at areas of damage. The size and locations of the areas of damage are obviously unknown. Attempts to carry out reference electrode potential surveys and linear polarization measurements have therefore been unable to come up with definitive criteria for corroding and non-corroding areas. The other problem is that the bars are isolated from each other, therefore a connection must be made to each bar measured to be sure that there is electrical contact. [Pg.96]

Several factors influencing localised form of corrosion in austenitic type SS316 LNwere studied. These include temperature of the medium and surface treatment by N-ion implantation. In the case of the welds, the role of solute elements have been independently examined through their influence on the ferrite content. In all the cases, electrochemical techniques like linear polarization measurements were employed to determine the corrosion sensitivity range and establish the corrosion resistance regimes. [Pg.101]

The measurement of the time dependence of gium may be used to probe various chiral aspects of excited state energetics, molecular dynamics, and reaction kinetics. Although there are some time-dependent circular polarization effects due to molecular reorientations that parallel time-dependent linear polarization measurements, the most interesting studies are those that involve the time-dependence of intrinsic molecular chirality. For a sample containing one chiral luminescent lanthanide chromophore, it might be the case that there are processes that affect chirality occurring on the same time scale as emission that could be probed by time-dependent CPL. To date, however, there have been no reports of such studies, and all of the time-dependent CPL measurements have involved racemic mixtures. [Pg.301]

Criteria relating linear polarization measurements to deterioration rates, similar to the ASTM C876 (1991) criteria for half cell potentials, have been published (Broomfield et aL, 1993). These show some comparability between different devices and will be discussed below under interpretation (Section 4.11.4). A set of conversion equations is provided in the final report of the Strategic Highway Research Program (SHRP) contract on corrosion rate measurement (Fliz et al., 1992). [Pg.81]

Receiving equipment for aircraft astrophysical investigations in the far infrared has been developed and flown in 1974-1975 on board the AN-30 aircraft. Four types of infrared and submillimeter detectors mainly of photoresistor type are used in the wavelength region from 10 mkm to 1 mm. Thermal background at the detectors is limited by cooled bandpass filters and by optimal matching of the detectors with the telescope optics. The spectral filters used are combinations of quasiresonance metal mesh filters of different structure and Q-factor from 2 to 7 with the Yamada cut-off powder filters. A tunable Fabry-Perot interferometer, a polarimeter for linear polarization measurements and an aircraft 25 cm-telescope are briefly described. [Pg.172]

Table 3. Electrochemical results of linear polarization measurements and corrosion inhibition efficiencies for A1 alloy in aqueous solution of 0.05 mold NaCl. Table 3. Electrochemical results of linear polarization measurements and corrosion inhibition efficiencies for A1 alloy in aqueous solution of 0.05 mold NaCl.
The polarization resistance method is based on the observation that the polarization curve close to the corrosion potential is linear (Fig. 8-8), the slope AE/AI (AE = step in potential, AI = resulting current) being defined as polarization resistance, Rp. The technique is called linear polarization measurement (LPR). The Rp value is related to the corrosion current by the formula (Stern-Geary, 1957) ... [Pg.972]

We perform on these photons linear polarization measurements. [Pg.104]

The vast introduction of the more sophisticated Fourier transform infrared (FT-IR) spectrometers for spectral studies made the CBS method senseless in terms of its further application. In the FT-IR analyses, the linearly polarized measurements are conducted by sequential photometrization of a sample for both positions of the polarizer. The linear dichroism is differentially registered by subtraction of the two spectra, which is implanented promptly and easily by the modem sophisticated FT-IR spectrophotometers, equipped with computerized systans. [Pg.18]