Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Limited service

Defect. A defect is an imperfection in a component, resulting from the way it was manufactured, shipped, handled, or installed, that may contribute materially to failure or limited serviceability. Failures resulting directly or indirectly from defects account for less than 1% of all failures. [Pg.313]

Introduction of the product into limited service with constant monitoring of its per-... [Pg.276]

Materials With Limited Service. The desirability of specifying some degree of production impact testing, in addition to the weld procedure qualification tests, when using materials with limited low-temperature service experience below the minimum temperature stated in Table IX-2. [Pg.38]

The production of volatile products upon irradiation can result in the undesirable formation of bubbles. This can lead to the premature failure of stressed components, thus limiting service life. The yield of volatile products after irradiation has been demonstrated to be a sensitive probe of the relative radiation resistance for model compounds such as cyclohexane and benzene, with G(H2) 5.6 (3) and 0.038 (4), respectively. [Pg.253]

Anisotropic powders of ferrites have excellent cost/performance ratio, limited service temperatures, and low electrical resistance. [Pg.214]

Protection of thiols. The r-butyl group has been of limited service for protection of thiols because removal has involved rather drastic treatment with liquid HF. r-Butyl thioethers can be cleaved by treatment with o-nitrobenzene-sulfenyl chloride in acetic acid at 25° to give S-o-nitrophenylsulfeny derivatives. These products are reduced to thiols with NaBH4, HSCH2C02H, or HOCH2CH2SH. [Pg.277]

Three basic problems may cause a total joint replacement to fail or to have a limited service life. The first problem, arises, because the elastic modulus of the stem greatly exceeds that of the bone. Flexural loading caused by walking creates local cyclic stress concentrations due to the non-compliance of the stem. These stresses can be intense and even severe enough to cause death of local bone cells. If this... [Pg.85]

A sometimes limited service mentality in the service units, with production seen rather as a petitioner than a customer. [Pg.258]

The principal services include provision of high level calibration services (Fig. 3) and/or standards to suppliers offering secondary services or standards, preparation of standards and reference materials, and limited services direct to field... [Pg.288]

Conventional coating approaches to TPO, which rely on the use of substrate pretreatments such as flaming, corona discharge, plasma or chemical pre-treatment, have led to a substantial oxidation of the surface, which enhances adhesion. These pretreatments, however, have a limited service life before the surface reverts to its unoxidized, apolar condition. [Pg.1303]

Limiting service to two terms will make U.S. presidents more effective. [Pg.57]

The A -halophthaliinides, A -hsloaoetauilidea, and AMialo-benzonoeulfonamides have soen only limited service as reagents for the preparation of halohydrins. [Pg.54]

Strong aikalies will damage the pipe. If the alkali content (pH) is expected to be high enough to destroy a vinyi ester mortar, it will probably be too high for the pipe itself. If this possibiiity arises the matter should be discussed with the pipe manufacturer or the National Clay Pipe Institute. Consider aiso the temperature at which liquid streams may enter the pipe. The cited standard limits service conditions to 140°F or lower. If very hot liquids are to enter the system, this too shouid be discussed with the pipe manufacturer. [Pg.288]

The second column describes a smaller laboratory that can process up to 125 samples per month. Although some laboratories start by offering limited services and then try to grow into a full-service facility, a minimum number of samples must be processed monthly to produce a revenue stream that will sustain operation. This minimum must be calculated for each type and quantity of sample, number and types of analytes requested, and facility overhead. [Pg.274]

If hardness is retained at a high level, weight gain has stabilized, and swelling has stabilized at the 12 month level, then the resin may do fairly well in limited service. [Pg.150]


See other pages where Limited service is mentioned: [Pg.312]    [Pg.395]    [Pg.27]    [Pg.28]    [Pg.30]    [Pg.31]    [Pg.32]    [Pg.112]    [Pg.933]    [Pg.16]    [Pg.27]    [Pg.28]    [Pg.30]    [Pg.31]    [Pg.32]    [Pg.34]    [Pg.503]    [Pg.312]    [Pg.1775]    [Pg.1858]    [Pg.138]    [Pg.181]    [Pg.503]    [Pg.373]    [Pg.54]    [Pg.79]    [Pg.943]    [Pg.1115]    [Pg.503]    [Pg.20]    [Pg.294]    [Pg.278]    [Pg.69]    [Pg.442]    [Pg.139]   
See also in sourсe #XX -- [ Pg.249 ]




SEARCH



Serviceability limits

© 2024 chempedia.info