Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Lead monitoring purposes

It is clear that neither NMEA nor NDPA is appropriate for an internal standard in NDMA determination if criteria are interpreted strictly, but both compounds have been used for this purpose. Addition of a nitrosamine, not normally present in the sample, is helpful in detecting any gross errors in the procedure, but the addition should not be considered to be internal standardization. Utilization of NMEA or NDPA to indicate recovery of NDMA can lead to significant errors. In most reports of the application of these "internal standards", recovery of all nitrosamines was close to 100%. Under these conditions, any added compound would appear to be a good internal standard, but none is necessary. NDMA is a particularly difficult compound for use of internal standardization because of its anomalous distribution behavior. I mass j ectrometry is employed for quantitative determination, H- or N-labeled NDMA could be added as internal standard. Because the labeled material would coelute from GC columns with the unlabeled NDMA, this approach is unworkable when GC-TEA is employed or when high resolution MS selected ion monitoring is used with the equipment described above. [Pg.339]

The purpose of this chapter is to describe the analytical methods that are available for detecting and/or measuring and monitoring lead in environmental media and in biological samples. The intent is not to provide an exhaustive list of analytical methods that could be used to detect and quantify lead. Rather, the intention is to identify well-established methods that are used as the standard methods of analysis. Many of the analytical methods used to detect lead in environmental samples are the methods approved by federal organizations such as EPA and the National Institute for Occupational Safety and Health (NIOSH). Other methods presented in this chapter are those that are approved by groups such as the Association of Official Analytical Chemists (AOAC) and the American Public Health Association (APHA). Additionally, analytical methods are included that refine previously used methods to obtain lower detection limits, and/or to improve accuracy, precision, and selectivity. [Pg.443]

Whereas the microprocessor controls an individual basic operation, the central computer, which has all the analytical procedures held in its memory, controls the particular analytical procedure required. At the appropriate time, the central computer transmits the relevant set of parameters to the corresponding units and provides the schedule for the sample-transport operation. All units are monitored to ensure proper functioning. If one of the units signals an error, a predetermined action, such as disposing of the sample, is taken. The basic results from the units are transferred to the central computer, the final results are calculated, and the report is passed to the output terminal. These results can also be transmitted to other data processing equipment for administrative or management purposes. The central control is, therefore, the leading element in a hierarchy of... [Pg.42]

Despite these caveats, IR is an excellent tool for API process monitoring because of its chemical information content. This is particularly valuable in early-stage development when it can yield crucial information about unexpected reaction intermediates and side reactions and therefore lead directly to a more robust process. Commercial instrumentation is widely available for this purpose [78] and development of cheaper, smaller and more rugged instrumentation continues apace [79]. For example, a miniaturised mid-infrared spectrometer and... [Pg.253]


See other pages where Lead monitoring purposes is mentioned: [Pg.63]    [Pg.101]    [Pg.63]    [Pg.101]    [Pg.19]    [Pg.408]    [Pg.276]    [Pg.833]    [Pg.59]    [Pg.353]    [Pg.63]    [Pg.98]    [Pg.99]    [Pg.101]    [Pg.103]    [Pg.105]    [Pg.107]    [Pg.453]    [Pg.302]    [Pg.296]    [Pg.337]    [Pg.121]    [Pg.172]    [Pg.238]    [Pg.77]    [Pg.71]    [Pg.367]    [Pg.525]    [Pg.92]    [Pg.132]    [Pg.178]    [Pg.35]    [Pg.74]    [Pg.195]    [Pg.415]    [Pg.392]    [Pg.77]    [Pg.418]    [Pg.443]    [Pg.365]    [Pg.13]    [Pg.9]    [Pg.103]    [Pg.64]    [Pg.108]    [Pg.780]   
See also in sourсe #XX -- [ Pg.101 , Pg.102 , Pg.103 , Pg.104 , Pg.105 , Pg.106 , Pg.107 , Pg.108 ]




SEARCH



Lead monitoring

Monitors/monitoring purpose

© 2024 chempedia.info