Ionization characteristic

An internal standard should meet the following three requirements. First, it should have the same or very similar physical-chemical properties as the analyte, particularly hydrophobicity and ionization characteristics, so that it can mimic closely the performance of the analyte in every stage of analysis, i.e., from sample preparation, chromatographic separation, to mass spectrometric detection. In this way, any losses during sample preparation or variations in the mass spectrometry detection can be corrected. [Pg.2]

Based on physiological-physicochemical arguments, constraints were proposed for Pc, i.e., to be set equal to 1000 when Pc > 1000 and 9 equal to 1 when 9 < 1. Equation (6.3) is, in reality, the first ever published explicit relationship between Fa and physicochemical drug properties. It was used to classify drugs according to their solubility, permeation, and ionization characteristics [158]. Moreover, (6.3) was monoparameterized ... [Pg.116]

It is also noteworthy that many of the in vitro results of vaginal permeability studies cited in the literature have limitations related to the experimental conditions that were used, particularly pH values at which they have been performed. Differences in permeability values are particularly expected when ionization characteristics change between experimental pH and vaginal pH [183], However, in vitro results should only be considered as evidence that the vaginal mucosa is able to be permeated. [Pg.838]

In contrast to the numerous advantages, high solvent and/or salt loads considerably alter the stabihty of the plasma and its excitation/ionization characteristics, which imposes more rigorous requirements for sample composition. [Pg.6085]

The value of pg largely reflects the pressure of the non-polymer-forming gases in the plasma (by-product of the plasma polymerization) when the conversion ratio of monomer to polymer is high. Therefore, the control of pg is important with respect to the ionization characteristics of the product gas, which is important for... [Pg.248]

Solution stability of a test drug in selected buffers (or pH conditions) should be documented using a validated stability-indicating assay. Data collected on both pH-solubility and pH-stability should be submitted in the biowaiver application along with information on the ionization characteristics, such as pKa(s), of a drug. [Pg.225]

Because many dmgs are quite polar, and their metabolites are even more polar, ESI is the method of choice for analyte ionization. As the biotransformation may lead to significant changes in the ionization characteristics of the analytes, data acquisition in both positive-ion and negative-ion mode is recommended. [Pg.261]

The choice of an ionization source must be consistent with the mass spectrometer inlet system, as described above, and the ionization characteristics of the analyte. Likewise, the appropriate choice of mass analyzer is highly application-, compound-, and matrix-dependent, and each mass analyzer requires certain characteristics from its ion detector The variety of individual ionization, mass analyzer, and ion detector systems that can be integrated creates a myriad of unique mass spectrometer systems, each with certain advantages and disadvantages. To add even more complexity to the situation, modular configuration of these individual components (ionization source, mass analyzer, and detector) is not limited... [Pg.26]

This covalent hydration20-22 due to the highly polarized nature of the pteridine nucleus, also occurs in pyrimidines, and in other 7r-deficieiit heterocyclic systems. This phenomenon has a profound effect on the ionization characteristics of pteridines, and explains why pteridine shows acidic properties on titration with base pKa 11.21) and shows a basic ionization with pKa 4.79.23 The 3,4-hydrated cation 8 initially formed from pteridine in acid slowly equilibrates with the 5,6,7,8-dihydrated cation 9.24... [Pg.272]

Connection to an element selective detector, such as ICP-MS, also causes problems. The large amount of organic solvents present cools the plasma and increases reflected power this results in plasma extinction at relatively low organic solvent concentrations. In addition, the ionization characteristic of the Ar-plasma is altered, resulting in changed sensitivity of the detector. The extremely high carbon intake induces polyatomic interferences and carbon precipitation on torch... [Pg.1655]

The introduction of any substance to water results in altered properties for the substance and water itself. The degree and type of alteration is dependent on the molecular and electronic structure, ionization characteristics, size, and stereochemistry of the solute. [Pg.6]

Microwaves are electromagnetic waves with frequencies in the range of 300-300 000 MHz. Microwave radiation neither possesses ionizing characteristics nor produces changes in the molecular structure it can be used to measure the movement of molecules due to the migration of ions and the rotation of dipoles. Of the four frequencies most often used in industrial and scientific applications (915 25, 2450 13, 5800 75, and 22125 125 MHz), the one with a power range 600-700 W (domestic ovens) is 2450 MHz, which can provide, to the microwave cavity, 43 500 cal in 5 min. [Pg.4273]

The applicability of ordered nanocavity arrays as SALDI substrates in the analysis of peptides and plant metabolites has been reported [50]. These Si nanocavities are about 200 nm in diameter and 200 nm deep, and are fabricated by nanosphere lithography coupled with reactive ion etching. The desorption/ionization characteristics of the arrays were found to depend heavily on the surface morphology. [Pg.377]

Halogenated solvents shonld be avoided to prevent their decomposition and their alteration of ionization characteristics that may occur. [Pg.320]


See other pages where Ionization characteristic is mentioned: [Pg.554]    [Pg.20]    [Pg.570]    [Pg.122]    [Pg.630]    [Pg.630]    [Pg.62]    [Pg.876]    [Pg.390]    [Pg.391]    [Pg.496]    [Pg.534]    [Pg.585]    [Pg.610]    [Pg.185]    [Pg.597]    [Pg.996]    [Pg.1657]    [Pg.167]    [Pg.188]    [Pg.342]    [Pg.400]    [Pg.168]    [Pg.156]    [Pg.20]    [Pg.107]    [Pg.228]    [Pg.228]    [Pg.229]    [Pg.409]    [Pg.43]   
See also in sourсe #XX -- [ Pg.1655 ]