Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Integrator threshold

The advantages of this kind of organization system are clear. Any issues with accuracy of transcription are alleviated. Since peak tables are automatically extracted from the data traces, there is no need for cut-and-paste functions. However, the destination path must be set prior to the transfer, and also the proper integration thresholds must be configured. Data can be part of multiple optimization/screening waves at the same time. In addition, there are... [Pg.515]

In this work we use an integral threshold of 10-8 au for the Cholesky decomposition of the two-electron matrix. [Pg.99]

Processing method Controls and documents integration parameters, component names, calibration and quantitation information Integration threshold, peak width, minimum peak area, integration events Component table component names, retention times, response factors... [Pg.125]

Table 6.5 shows the effect of integral thresholds on the calculated properties of cyclic clusters. [Pg.226]

Table 6.5. Effect of integral thresholds on calculated properties of cyclic clusters CL 12.1 and CL16.3 total energy E and top of valence band e (a.u.), Lowdin charge gxi of Ti, total number of electrons per unit cell calculated using (6.76) within the corresponding cyclic cluster and within the interaction radius defined by the integral thresholds (JV )... Table 6.5. Effect of integral thresholds on calculated properties of cyclic clusters CL 12.1 and CL16.3 total energy E and top of valence band e (a.u.), Lowdin charge gxi of Ti, total number of electrons per unit cell calculated using (6.76) within the corresponding cyclic cluster and within the interaction radius defined by the integral thresholds (JV )...
Two teachers who act directly in these two workplaces participated in this research. For the assessment of occupational noise it was used a dosimeter of the Instrutherm brand, DOS-500 model, strictly calibrated by the CAL 3000 calibrator device, from the same vendor, and both with calibration certificate. Following the recommendations of NR-15 (Brasil 1978a), and considering the workplace as a continuous noise generator, the dosimeter was aet up for an A compensation circuit, SLOW response circuit, due to the characteristics of the noise in the environment rate of Exchange (duplicity) set to q = 5 and integration threshold at 80 dB (A). ... [Pg.238]

Figure 4 Typical timing behavior of the quadratic Fock matrix formation versus the cubically scaling diagonalization step (small prefactor) in SCF energy calculations. The timings for a conventional Fock matrix formation, the linear-scaling CFMM/LinK schemes (as explained later in this review), and Fock matrix diagonalization for a series of DNA molecules (A-T), = 1 — 16 are depicted. Integral threshold is 10 , basis set 6-31G. ... Figure 4 Typical timing behavior of the quadratic Fock matrix formation versus the cubically scaling diagonalization step (small prefactor) in SCF energy calculations. The timings for a conventional Fock matrix formation, the linear-scaling CFMM/LinK schemes (as explained later in this review), and Fock matrix diagonalization for a series of DNA molecules (A-T), = 1 — 16 are depicted. Integral threshold is 10 , basis set 6-31G. ...
The encircling coils data are the basis for stmctural integrity analysis. At a defined threshold, detailed analysis with the pancake coils is performed, thereby defining the type of defect. [Pg.1008]

Set this threshold Lo a small positive constant (the default value is 10 Hartrcc), Tli is tli resh old is used by HyperCh cm to igu ore all two-cicetron repulsion in tegrals with an absolute value less th an th is value. Tli is option controls the performance of the SCF itera-lious and the accuracy of the wave function and energies since it can decrease the number of ealeulatcd Iwo-elcclrou integrals. [Pg.113]

The threshold limit value—time integrated average, TLV—TWA, of chlorine dioxide is 0.1 ppm, and the threshold limit value—short-term exposure limit, STEL, is 0.3 ppm or 0.9 mg /m of air concentration (87,88). Chlorine dioxide is a severe respiratory and eye irritant. Symptoms of exposure by inhalation include eye and throat irritation, headache, nausea, nasal discharge, coughing, wheezing, bronchitis, and delayed onset of pulmonary edema. Delayed deaths occurred in animals after exposure to 150—200 ppm for less than one hour. Rats repeatedly exposed to 10 ppm died after 10 to 13 days of exposure. Exposure of a worker to 19 ppm for an unspecified time was fatal. The ingested systemic effects of low concentration chlorine dioxide solutions are similar to that of chlorite. [Pg.484]

The measured values of L and Vc together with known values of obtain information concerning the function Q(E>. The limits of integrations of Equation 1 are xmax = L[1 — (E0/Vc)1/2] as determined by threshold requirement of the reaction and Emax =... [Pg.327]

EL = emissions level ERA = Environmental Protection Agency HSDB = Hazardous Substances Data Bank lARC = International Agency for Research on Cancer IRIS = Integrated Risk Information System NIOSH = National Institute of Occupational Safety and Health OEL = occupational exposure limit OSHA = Occupational Safety and Health Administration PEL = permissible exposure limit RAC = reference air concentration REL = recommended exposure limit RCRA = Resource Conservation and Recovery Act RfD = reference dose TLV = threshold limit value TWA = time-weighted average WHO = World Health Organization... [Pg.190]

Figure 32.2 Infrastructure required for integrated health care. Reproduced with permission from Threshold of Innovation (2005). IBM Business Consulting Services [1]. See color plate. Figure 32.2 Infrastructure required for integrated health care. Reproduced with permission from Threshold of Innovation (2005). IBM Business Consulting Services [1]. See color plate.
If the threshold and minimum peak heights/areas were appropriately defined, then only peaks 1 and 7-12 would be integrated, making the report much easier to read. [Pg.66]


See other pages where Integrator threshold is mentioned: [Pg.33]    [Pg.168]    [Pg.221]    [Pg.226]    [Pg.227]    [Pg.228]    [Pg.2634]    [Pg.33]    [Pg.168]    [Pg.221]    [Pg.226]    [Pg.227]    [Pg.228]    [Pg.2634]    [Pg.136]    [Pg.263]    [Pg.265]    [Pg.154]    [Pg.263]    [Pg.265]    [Pg.203]    [Pg.55]    [Pg.545]    [Pg.140]    [Pg.359]    [Pg.46]    [Pg.138]    [Pg.624]    [Pg.627]    [Pg.203]    [Pg.242]    [Pg.313]    [Pg.202]    [Pg.102]    [Pg.268]    [Pg.107]    [Pg.70]    [Pg.67]   
See also in sourсe #XX -- [ Pg.304 ]

See also in sourсe #XX -- [ Pg.274 ]




SEARCH



Integral Threshold

© 2024 chempedia.info