Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Instantaneous technique

In the real world corrosion rates always change with time, for instance some forms of localized corrosion such as microbiologically influenced corrosion can accelerate rapidly and grow exponentially once initiated, and therefore it is important to identify the specific time periods of maximum corrosion rates and the effects of corrosion inhibitors. For this reason instantaneous techniques are important for continuous measirrement of the prevailing corrosion rates for... [Pg.46]

Perturbation or relaxation techniques are applied to chemical reaction systems with a well-defined equilibrium. An instantaneous change of one or several state fiinctions causes the system to relax into its new equilibrium [29]. In gas-phase kmetics, the perturbations typically exploit the temperature (r-jump) and pressure (P-jump) dependence of chemical equilibria [6]. The relaxation kinetics are monitored by spectroscopic methods. [Pg.2118]

Rates of Reaction. The rates of formation and dissociation of displacement reactions are important in the practical appHcations of chelation. Complexation of many metal ions, particulady the divalent ones, is almost instantaneous, but reaction rates of many higher valence ions are slow enough to measure by ordinary kinetic techniques. Rates with some ions, notably Cr(III) and Co (III), maybe very slow. Systems that equiUbrate rapidly are termed kinetically labile, and those that are slow are called kinetically inert. Inertness may give the appearance of stabiUty, but a complex that is apparentiy stable because of kinetic inertness maybe unstable in the thermodynamic equihbrium sense. [Pg.386]

The flux-corrected-transport technique was also used by Phillips (1980), who successfully simulated the process of propagation of a detonation wave by a very simple mechanism. The reactive mixture was modeled to release its complete heat of combustion instantaneously after some prescribed temperature was attained by compression. A spherical detonation wave, simulated in this way, showed a correct propagation velocity and Taylor wave shape. [Pg.108]

There are obviously many reactions that are too fast to investigate by ordinary mixing techniques. Some important examples are proton transfers, enzymatic reactions, and noncovalent complex formation. Prior to the second half of the 20th century, these reactions were referred to as instantaneous because their kinetics could not be studied. It is now possible to measure the rates of such reactions. In Section 4.1 we will find that the fastest reactions have half-lives of the order 10 s, so the fast reaction regime encompasses a much wider range of rates than does the conventional study of kinetics. [Pg.133]

Linear polarization instruments provide an instantaneous corrosion-rate data, by utilizing polarization phenomena. These instruments are commercially available as two-electrode Corrater and three electrode Pairmeter (Figure 4-472). The instruments are portable, with probes that can be utilized at several locations in the drilling fluid circulatory systems. In both Corrater and Pairmeter, the technique involves monitoring electrical potential of one of the electrodes with respect to one of the other electrodes as a small electrical current is applied. The amount of applied current necessary to change potential (no more than 10 to 20 mV) is proportional to corrosion intensity. The electronic meter converts the amount of current to read out a number that represents the corrosion rate in mpy. Before recording the data, sufficient time should be allowed for the electrodes to reach equilibrium with the environment. The corrosion-rate reading obtained by these instruments is due to corrosion of the probe element at that instant [184]. [Pg.1312]

A number of corrosion-monitoring techniques based on electrochemical principles are available. These give an indication of the instantaneous corrosion rate, which is of use when changing process conditions create a variety of corrosion effects at different times in a plant. Some... [Pg.911]

Unsaturated polyester finishes of this type do not need to be stoved to effect crosslinking, but will cure at room temperature once a suitable peroxide initiator cobalt salt activator are added. The system then has a finite pot life and needs to be applied soon after mixing. Such a system is an example of a two-pack system. That is the finish is supplied in two packages to be mixed shortly before use, with obvious limitations. However, polymerisation can also be induced by ultra violet radiation or electron beam exposure when polymerisation occurs almost instantaneously. These techniques are used widely in packaging, particularly cans, for which many other unsaturated polymers, such as unsaturated acrylic resins have been devised. [Pg.676]

Polarisation resistance This technique, sometimes referred to as linear polarisation resistance (LPR), has been applied widely in industrial monitoring because of its ability to react instantaneously to a corrosion situation or change in corrosion rate " " . The limitation of the technique arises from the necessity to have a defined electrolyte as the corrosive (the author has seen an LPR probe installed in a dry gas-line in an oil refinery). [Pg.1138]

A different approach consists of stepwise changing the adsorbent temperature and keeping it constant at each of the prefixed values Tx, Ts,. . ., Tn for a certain time interval (e.g. 10 sec), thereby yielding the so-called step desorption spectra s(81-85). The advantage of this method lies in a long interval (in terms of the flash desorption technique) for which the individual temperatures Ti are kept constant so that possible surface rearrangements can take place (81-83). Furthermore, an exact evaluation of the rate constant kd is amenable as well as a better resolution of superimposed peaks on a desorption curve (see Section VI). What is questionable is how closely an instantaneous change in the adsorbent temperature can be attained. This method has been rarely used as yet. [Pg.362]

These instruments, sometimes referred to also as sediment accumulation devices, weight the sediment as it accumulates on a weigh-pan at the base of the sedimentation column. The methods are cumulative ones. With the development of sensitive electro balances, the cumulative sedimentation technique is generally easier to perform and more accurate than is the incremental technique. The powder may be dispersed initially in the bulk of the fluid or added instantaneously at the top. An advantage of this type of equipment is the absence of the conical base, needed in sediment extraction devices, upon the walls of which some sediment may adhere. The danger of particles sticking to the vertical walls is however still present... [Pg.526]

Because an instantaneous rate is a derivative of concentration with respect to time, we can use the techniques of integral calculus to find the change in [A] as a function of time. First, we divide both sides by A and multiply through by — dt ... [Pg.661]

An individual isothermal surface can be traced with the help of laser tomography, also known as laser sheet imaging, where a laser sheet and oil droplets are combined to visualize the instantaneous flame surface in a plane. This technique is ideal when wrinkling of an isoline is of interest besides, typically it shows the area occupied by the combustion products if the instantaneous flame thickness is small, such as a black area in... [Pg.143]

Polarization resistance (Rp) techniques can be used to continuously monitor the instantaneous corrosion rate of a metal. Mansfeld provided a thorough review of the use of the polarization resistance technique for the measurement of corrosion currents. R is defined as ... [Pg.209]

Upon injection of CD into the reactor during racemic hydrogenation the rate acceleration was always instantaneous, while the optical yield vs conversion dependencies showed a monotonic increase type behaviour as seen in Figure 7. In acetic acid the increase part of the above dependence is so fast that it hardly can be followed by our sampling technique. At low concentration of modifier the optical yield passes through a maximum In this case the... [Pg.245]


See other pages where Instantaneous technique is mentioned: [Pg.37]    [Pg.392]    [Pg.37]    [Pg.392]    [Pg.511]    [Pg.432]    [Pg.513]    [Pg.2428]    [Pg.2430]    [Pg.313]    [Pg.1241]    [Pg.189]    [Pg.395]    [Pg.15]    [Pg.727]    [Pg.1006]    [Pg.444]    [Pg.71]    [Pg.443]    [Pg.557]    [Pg.31]    [Pg.94]    [Pg.147]    [Pg.154]    [Pg.196]    [Pg.337]    [Pg.110]    [Pg.395]    [Pg.308]    [Pg.287]    [Pg.128]    [Pg.219]    [Pg.118]    [Pg.18]    [Pg.17]   
See also in sourсe #XX -- [ Pg.36 ]




SEARCH



Instantaneous

Instantaneous normal mode techniques

© 2024 chempedia.info