Inductively coupled plasma optical emission with laser ablation

Since the mid-1960s, a variety of analytical chemistry techniques have been used to characterize obsidian sources and artifacts for provenance research (4, 32-36). The most common of these methods include optical emission spectroscopy (OES), atomic absorption spectroscopy (AAS), particle-induced X-ray emission spectroscopy (PIXE), inductively coupled plasma-mass spectrometry (ICP-MS), laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS), X-ray fluorescence spectroscopy (XRF), and neutron activation analysis (NAA). When selecting a method of analysis for obsidian, one must consider accuracy, precision, cost, promptness of results, existence of comparative data, and availability. Most of the above-mentioned techniques are capable of determining a number of elements, but some of the methods are more labor-intensive, more destructive, and less precise than others. The two methods with the longest and most successful histoty of success for obsidian provenance research are XRF and NAA. [Pg.527]

Minute amounts of sample material ablated with the focused radiation of a pulsed laser are transported into an independent excitation source, e.g., inductively coupled plasma (ICP) for further atomization, excitation, or ionization. The detection of target atoms after laser ablation (LA) is performed by hyphenated techniques using optical emission or mass spectrometry LA-ICP-OES laser ablation-lCP-optical emission spectroscopy LA-ICP-MS laser ablation-l CP-mass spectrometry... [Pg.2454]

Preferred methods in trace determination of the elements include atomic absorption spectrometry (AAS), optical emission spectrometry (OES) with any of a wide variety of excitation sources [e.g., sparks, arcs, high-frequency or microwave plasmas (inductively coupled plasma, ICP microwave induced plasma, MIP capacitively coupled micro-wave plasma, CMP), glow discharges (GD). hollow cathodes, or laser vaporization (laser ablation)], as well as mass spectrometry (again in combination with the various excitation sources listed), together with several types of X-ray fluorescence (XRF) analysis [51]. [Pg.17]


See other pages where Inductively coupled plasma optical emission with laser ablation is mentioned: [Pg.28]    [Pg.562]    [Pg.544]    [Pg.614]    [Pg.448]    [Pg.323]    [Pg.428]   


SEARCH



Ablate

Ablation

Ablator

Ablators

Coupled Plasma

Induction-coupled plasma

Inductive coupled plasma

Inductive coupling

Inductively couple plasma

Inductively coupled

Inductively coupled plasma emission

Inductively coupled plasma optical

Inductively coupled plasma-optical emission

Laser ablation

Laser ablation inductively coupled plasma

Laser ablation-inductively coupled

Laser emission

Laser optical

Lasers plasma

Optical emission

Optical induction

Plasma ablation

Plasma laser ablation

© 2024 chempedia.info