Imaging study sample preparation

LEED requires a coherence length of ordered domains on the order of at least 100 A to be useful (36). SEM images are typically limited to resolution of 50 A, but are useful due to their depth of field and wide field of view (37). High resolution TEM can yield images of solids to a resolution of 1-2 A, but requires extensive sample preparation and also requires that the surface atoms be in registry with the remainder of the bulk sample under study (14,38). Clearly, each technique provides valuable information which complements the others, and ideally a combination of the probes would be used to obtain a complete characterization of the surface under study. [Pg.176]

The OLED is composed of hard and soft layers so that the conventional cross-sectional TEM sample preparation techniques cannot be applied. Figure 10.3 is a first DB microscopy-prepared TEM image of an OLED in cross-sectional view [37], The glass substrate, ITO, organic layers, and A1 cathode are indicated in the image. The microstructure and interfaces of all these layers can be well studied now. The nanometer-sized spots in organic layers are indium-rich particles. We believe the combination of DB microscopy and TEM will greatly advance the OLED research and development in the near future. [Pg.621]

Since one of the issues raised in this paper is whether the objects seen in the TEM images are a proper representation of the structures present in solution, we will describe briefly sample preparation strategies. For solutions of micelles in hexane, a very volatile solvent, samples for TEM studies could be obtained by aspirating a dilute solution directly onto a carbon-coated copper grid. Most of the solvent likely evaporated as the sample was deposited on the substrate. Alternatively, the TEM substrate could be dipped briefly into a dilute solution of the micelles and allowed to dry. This method also worked for less volatile solvents like decane. For decane, we could also place a small drop (a few pi) of solution on the grid and then touch the edge of the droplet with a Kimwipe to remove excess solvent. For several samples these methods were compared, and we observed the same morphology. [Pg.153]

In conclusion, the relative ease of sample preparation, once the engineered cell lines are developed, makes such image-based studies suitable for extension to... [Pg.399]


See other pages where Imaging study sample preparation is mentioned: [Pg.181]    [Pg.340]    [Pg.31]    [Pg.1668]    [Pg.542]    [Pg.282]    [Pg.371]    [Pg.555]    [Pg.231]    [Pg.207]    [Pg.30]    [Pg.392]    [Pg.404]    [Pg.267]    [Pg.272]    [Pg.279]    [Pg.284]    [Pg.51]    [Pg.270]    [Pg.98]    [Pg.317]    [Pg.118]    [Pg.130]    [Pg.28]    [Pg.334]    [Pg.542]    [Pg.72]    [Pg.526]    [Pg.577]    [Pg.219]    [Pg.256]    [Pg.502]    [Pg.283]    [Pg.591]    [Pg.268]    [Pg.277]    [Pg.377]    [Pg.189]    [Pg.20]    [Pg.177]    [Pg.179]    [Pg.239]    [Pg.50]    [Pg.451]    [Pg.334]   
See also in sourсe #XX -- [ Pg.271 ]