Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ignition systems for

Does anyone know where to get an electronic easily-adjustable ignition system for a single cylinder lawn-mower type engine It would be great if you could advance or retard timing just by turning a knob. [Pg.9]

There are magnetron ignition systems for small engines and my local mower shop said they could get them. Check them out because they may be adjustable like you need. [Pg.9]

Igniter System for Bangalore Torpedo is described under Demolition Tubes and in Ref 2, pp 215—17 with Fig 162... [Pg.482]

Automobile electric ignition system (Charles F. Kettering) Kettering invents the first electric ignition system for cars. [Pg.2052]

Greases may be made by blending the polymer with an inert filler such as a fine silica, carbon black or metallic soap. The silicone-silica greases are used primarily as electrical greases for such applications as aircraft and car ignition systems. [Pg.827]

Standard for gauging flammability. The most common systems for designating flammability are the Department of Transportation (DOT) definitions, the National Fire Protection Association s (NFPA) system, and the Environmental Protection Agency s (EPA) Resource Conservation and Recovery Act s (RCRA) definition of ignitable wastes, all of which use flashpoint in their schemes. The NFPA diamond, which comprises the backbone of the NFPA Hazard Signal System, uses a four-quadrant diamond to display the... [Pg.171]

External events are accident initiators that do not fit well into the central PSA structure used for "internal events." Some "external events" such as fire due to ignition of electrical wires, or flood from a ruptured service water pipe occur inside the plant. Others, such as earthquakes and tornados, occur outside of the plant. Either may cause failures in a plant like internal events. External initiators may cause multiple failures of independent equipment thereby preventing action of presumably redundant protection systems. For example, severe offsite flooding may fli 1 the pump room and disable cooling systems. An earthquake may impede evacuation of the nearby populace. These multiple effects must be considered in the analysis of the effects of external events. [Pg.185]

It was not nndl the 1950s that detonation flame arresters made of crimped metal ribbon elements were developed and began to be used more freqnendy (Binks 1999). The major impetus for die use of crimped metal ribbon detonation flame arresters in the US was the enactment of clean air legislation (Clean Air Act of 1990) which inadvertently created a safety problem by requiring reductions in volatile organic compound (VOC) emissions. To do this, manifolded vent systems (vapor collection systems) were increasingly installed in many chemical process industry plants which captured VOC vapors and transported them to suitable recovery, recycle, or destruction systems. This emission control requirement has led to the introdnction of ignition risks, for example, from a flare or via spontaneous combustion of an activated carbon adsorber bed. Multiple... [Pg.6]


See other pages where Ignition systems for is mentioned: [Pg.268]    [Pg.978]    [Pg.8]    [Pg.27]    [Pg.9]    [Pg.608]    [Pg.979]    [Pg.609]    [Pg.887]    [Pg.534]    [Pg.268]    [Pg.978]    [Pg.8]    [Pg.27]    [Pg.9]    [Pg.608]    [Pg.979]    [Pg.609]    [Pg.887]    [Pg.534]    [Pg.1103]    [Pg.425]    [Pg.428]    [Pg.151]    [Pg.151]    [Pg.128]    [Pg.457]    [Pg.409]    [Pg.247]    [Pg.293]    [Pg.486]    [Pg.300]    [Pg.570]    [Pg.24]    [Pg.400]    [Pg.336]    [Pg.482]    [Pg.2337]    [Pg.2494]    [Pg.629]    [Pg.23]    [Pg.267]    [Pg.268]    [Pg.523]    [Pg.524]    [Pg.120]    [Pg.515]    [Pg.377]    [Pg.445]    [Pg.941]   
See also in sourсe #XX -- [ Pg.88 ]




SEARCH



Igniter system

Ignition system

© 2024 chempedia.info