Humidity sensors operation

In several cases application of various additives to the surface of a semiconductor adsorbent, specifically adsorbing or reacting with particles to be detected enables one to improve selectivity. As an example we can mention the use of hygroscopic salts to bind water in humidity sensors, the application of particles of sulfanilic acid to the surface of hhO to detect NO2 [10]. However, the high operational temperature in majority of semiconductor sensors deprives the method of specific surface additives of its general character. [Pg.104]

The major requirement for a reliable hydrogen sensor operation in the fuel cell environment is in 100% condensing humidity Most of the fuel cells have abundant humidity and the sensor needs to operate continuously in humid environments. In some cases, the hydrogen sensor can also be operated at very low temperatures (as low as —40°C). The fuel cells regularly have a cold start, when operated from a very low ambient temperature the sensor needs to attain ambient temperature quickly (<30 s) and continue operation well below ambient temperature before the fuel cell itself reaches the ambient temperature. [Pg.528]

Fig. I. Resistance characienwiev of typical Dunmore and Pope sensors, la) Dunmure sensors are limited to a narrow range of humidity. This sensor operates between 40 and 6(1% RH tbi Pope sensors operate over a wide humidity range, hut output impedance of the sensor varies tram I(NXI ohms 1100% RH) to several megohms (10% RH). which complicates readout circuitry... Fig. I. Resistance characienwiev of typical Dunmore and Pope sensors, la) Dunmure sensors are limited to a narrow range of humidity. This sensor operates between 40 and 6(1% RH tbi Pope sensors operate over a wide humidity range, hut output impedance of the sensor varies tram I(NXI ohms 1100% RH) to several megohms (10% RH). which complicates readout circuitry...
Applications. The saturated salt sensor has certain advantages over other electrical humidity sensors, such as % RH instruments. Because the salt sensor operates as a current earner saturated with Li and Ci ions, addition of contaminating ions has little effect on its behavior compared to a typical RH sensor, which operates "starved" of ions and is easily contaminated. A properly designed saturated sail sensor is not easily contaminated since, from an ionic standpoint, it can be considered precontaminaied. [Pg.813]

The operating ranges of different humidity sensors. Most humidity/dew point detectors can make measurements at higher values of humidity and temperature, but are limited at low temperatures and at low concentrations. Most are also limited to a maximum operatng temperature of about 200°F (95°C). [Pg.355]

On the basis of the above results, one can suggest the development of the prototypes of nanosized resistors, thermoresistors and humidity sensors. In a TEMPOS (MOSBIT) device of 1 cm area, typically 10 to 10 of such nanodevices would operate simultaneously and parallel to each other. [Pg.631]

The humidity of the room where the product is exposed should be considered a critical parameter when a humidity-sensitive product is being manufactured. The humidity sensors and the humidity monitoring system should, therefore, be qualified. The heat transfer system, chemical drier or steam humidifier, which is prodiicing the humidity controlled air, is further removed from the product and may not require operational qualification. [Pg.79]

Shimizu Y etal 1989 The sensing mechanism in a semiconducting humidity sensor with platinum electrodes J. Electrochem. Soc. 136 3868-71 Lukaszewicz J P 1991 Diode-type humidity sensor using perovskite-type oxides operable at room temperature Sensors Actuators B 4 227-32 Anderson RC etal 1990 Investigations of porous silicon for vapor sensing Sensors Actuators A 23 835-9... [Pg.479]

Develop a hydrogen safety sensor operating at 500°C or below, having Is response time and being insensitive to humidity and hydrocarbons. [Pg.473]

Carbon Monoxide (a) 1-100 ppm reformate pre-stack sensor Operational tern perature <150°C Response time 0.1-1 sec Gas environment high-humidity reformer/partial oxidation gas H23O-75%, CO2, CO, N2, H2O at 1-3 atm total pressure Accuracy 1-10% full scale... [Pg.633]

When water molecules are adsorbed on semiconducting oxides, the conductivity increases or decreases according to whether the oxides are n- or p-type. In response to demands for operation at elevated temperatures, semiconductor humidity sensors using metal oxides, such as perovskite-type oxide, have been proposed as shown in Table 20-2. [Pg.297]

The impedance-type humidity sensor has the advantages of simple structure and rapid response. Moreover, long term operation becomes possible when the element has been stabilized by coating with a resin film. This type of sensor is also easily compatible, depends on the chemical structure of the polymers, and, in principle, enhancement of the water sensitivity can be achieved by cross-linking or copolymerisation. [Pg.301]

Fig. 8.3. (Left) Solid state OECT humidity sensor printed on polyethylene-coated paper. (Right) The sensor was capable of operating when bent at a radius of curvature of approximately 5 cm. Reprinted from [9] with permission from Elsevier... Fig. 8.3. (Left) Solid state OECT humidity sensor printed on polyethylene-coated paper. (Right) The sensor was capable of operating when bent at a radius of curvature of approximately 5 cm. Reprinted from [9] with permission from Elsevier...
The digital temperature-humidity sensor SHTl 1 is used to detect the temperature and the humidity underground. The temperature and the humidity can be detected by the SHTll sensor at the same time. The operating range of the temperature is 0 tl23.8°C, the temperature accuracy... [Pg.133]

Direction and Control of the Dryer The operation of the dryer is directed and controlled as follows. Solar blowers 2 start when the temperature in the drying space Td is lower than the collector outlet temperature T, dampers 8 are open. Blowers are activated by an on-off temperature control device. As a precondition of the operation of blowers the relative humidity should be lower than the set point value Set point selection is manual. If the internal fans 4 are on. The operation of the exhaust blowers 6 is controlled by the signal of the relative humidity sensor f/j situated behind the internal fans. The set point [/2s high initially and should be reduced in the progress of drying. Exhaust blowers are activated if U2 > t/2s- drying space the relative humidity should also be above a minimum level When humidifier 11 will be activated by the... [Pg.343]

It is shown in Fig. 9 that the impedance curves of the sensor operated in a dry environment do not depend very much on time. The same can be said about the curves taken at various humidities. The results also show that the quasi-semidrcular curves shrink continuously with humidity (i.e., the curves for lower humidity lie in between the curves for dry atmosphere and the curves for more humid atmosphere). [Pg.87]

A problem with these conductors is that humidity in the ambient atmosphere affects the conductivities and hence sensing characteristics when an amperometric mode of operation is adopted, as described later. The sensing electrodes have been provided mostly by Pt, and the counter electrodes by Ag, PdH, TiH, H0.35M0O3, H,W03, etc. The gases to be measured extended from H2 in inert gases to in air in 1982, and now seem to also include CO, NH3 and NO, all diluted in air, as well as O2 in the gas phase or condensed phase. Besides the examples given in Table 35.1, proton conductors have been used in humidity sensors, e.g. NAFION membrane in room temperature operation type , antimonic... [Pg.527]

Humidity sensors The measurement of humidity is essential for various industrial process operations, such as in the control of drying plant, ovens, and effluent gases from metal refining furnaces, mineral processing kilns, power plants, chemical plants, and incinerators. Adequate expression of the measured gas pollutant concentrations (on a dry basis) relies on a reliable measurement of the humidity in the process environment. [Pg.3880]

Chen Z, Lu C (2005) Humidity sensors a review of materials and mechanisms. Sensor Lett 3 274-295 Choi MMF, Hawkin P (2003) Development of an optical hydrogen sulphide sensor. Sens Actuators B 90 211-215 Chou J (2000) Hazardous gas monitors a practical guide to selection, operation and apphcation. McGraw-HiU, New York Cleaver KD (2001) The analysis of process gases a review. Accred Qual Assur 6(1) 8-15... [Pg.43]


See other pages where Humidity sensors operation is mentioned: [Pg.307]    [Pg.368]    [Pg.392]    [Pg.307]    [Pg.368]    [Pg.392]    [Pg.303]    [Pg.499]    [Pg.529]    [Pg.93]    [Pg.194]    [Pg.147]    [Pg.159]    [Pg.470]    [Pg.37]    [Pg.241]    [Pg.242]    [Pg.369]    [Pg.633]    [Pg.282]    [Pg.291]    [Pg.303]    [Pg.250]    [Pg.159]    [Pg.26]    [Pg.333]    [Pg.17]    [Pg.7]    [Pg.42]    [Pg.438]    [Pg.1976]    [Pg.80]    [Pg.93]   