Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Heterochromatic flicker photometry

Bone, R. A. et al. (2007b). Validity of macular pigment optical density measurements by heterochromatic flicker photometry. Investigative Ophthalmology and Visual Science 48(ARVO E-Abstract) 2131. [Pg.84]

Delori, F. C. et al. (2001). Macular pigment density measured by autofluorescence spectrometry Comparison with reflectometry and heterochromatic flicker photometry. Journal of the Optical Society of America A 18 1212-1230. [Pg.84]

Stringham, J. M. et al. (2008). The utility of using customized heterochromatic flicker photometry (cHFP) to measure macular pigment in patients with age-related macular degeneration. Experimental Eye Research 87 445 153. [Pg.84]

Snodderly DM, Mares JA, Wooten BR, Oxton L, Gruber M, and Ficek T (2004), Macular pigment measurement by heterochromatic flicker photometry in older subjects The carotenoids and age-related eye disease study, Invest. Ophthalmol. Visual Sci. 45 531-538. [Pg.109]

Figure 5.2 MP density measured at peak absorbance along the horizontal meridian using heterochromatic flicker photometry on one subject. Figure 5.2 MP density measured at peak absorbance along the horizontal meridian using heterochromatic flicker photometry on one subject.
Wooten, B.R., and Hammond, B.R. Spectral absorbance and spatial distribution of macular pigment using heterochromatic flicker photometry, Optom. Vis. Sci., 82(5), 378-386, 2005. [Pg.102]

Bone RA, Landrum JT (2004) Heterochromatic flicker photometry. Arch Biochem Biophys... [Pg.3951]

Neelam K, O Gorman N, Nolan J, O Donovan O, Wong HB, Eong KGA, Beatty S (2005) Measurement of macular pigment Raman spectroscopy versus heterochromatic flicker photometry. Invest Ophthalmol Vis Sci 46 1023-1032. doi 10.1167/iovs.04-1032... [Pg.3951]

Hagen S, Krebs I, Gittenberg C, Binder S (2010) Repeated measures of macular pigment optical density to test reproducibility of heterochromatic flicker photometry. Acta Ophthalmol 88 207-211... [Pg.3952]

Heterochromatic flicker photometry (HFP), 3931, 3932, 3934, 3935 Heterocyclic compounds, 978 Heterodimers, 2388... [Pg.4199]


See other pages where Heterochromatic flicker photometry is mentioned: [Pg.75]    [Pg.76]    [Pg.76]    [Pg.88]    [Pg.266]    [Pg.92]    [Pg.103]    [Pg.103]    [Pg.3924]    [Pg.3931]    [Pg.3932]   
See also in sourсe #XX -- [ Pg.76 , Pg.77 , Pg.78 ]




SEARCH



Flicker

Flicker/flickering

Photometry

© 2024 chempedia.info