Heat exchange calorimeters

Differential scanning calorimetry (DSC) can be performed in heat compensating calorimeters (as the adiabatic calorimetry), and heat-exchanging calorimeters (Hemminger, 1989 Speyer, 1994 Brown, 1998). [Pg.308]

The composition of the zeolites studied, which were kindly supplied by S. P. Zhdanov, is shown in Table I. Differential heat of adsorption of water was measured with an isothermal constant heat exchange calorimeter (17) at 23 °C. The heat of adsorption of the alcohols was measured with a variant of this calorimeter (J). The heat of adsorption of ethane and ethylene was determined from isosteres. The zeolites were pretreated by evacuating at 400°C for 30 hours. [Pg.185]

Heat exchange calorimeters actively exchange heat between the... [Pg.137]

Heat Calvet Calorimetry A Calvet calorimeter is a heat exchanging calorimeter with a cylindrical type detector working in isothermal and scanning modes. [Pg.71]

Calorimeters are insulated to ensure that negligible heat is transferred between the calorimeter and its surroundings during the experiment. As a result, the only heat exchange is between the chemicals and the calorimeter ... [Pg.389]

All calorimeters are composed of an inner vessel (the calorimeter vessel, A in Fig. 1), in which the thermal phenomenon under study is produced, and of a surrounding medium (shields, thermostat, etc., B in Fig. 1). Depending upon the intensity of the heat exchange between the inner vessel and its surroundings, three main types of calorimeters may be distinguished theoretically as indicated in Fig. 1. [Pg.194]

When there is no heat exchange between the inner vessel and its surroundings (adiabatic calorimeter, 1 in Fig. 1), the temperature of the calorimeter vessel varies when heat is liberated or absorbed. The quantity of heat produced or absorbed may be calculated from this temperature change, if the heat capacity of the inner vessel and of its contents is known. [Pg.194]

Since heat exchange between the calorimeter vessel and the heat sink is not hindered in a heat-flow calorimeter, the temperature changes produced by the thermal phenomenon under investigation are usually very small (less than 10 4 degree in a Calvet microcalorimeter, for instance) (23). For most practical purposes, measurements in a heat-flow calorimeter may be considered as performed under isothermal conditions. [Pg.196]

Adiabatic calorimetry uses the temperature change as the measurand at nearly adiabatic conditions. When a reaction occurs in the sample chamber, or energy is supplied electrically to the sample (i.e. in heat capacity calorimetry), the temperature rise of the sample chamber is balanced by an identical temperature rise of the adiabatic shield. The heat capacity or enthalpy of a reaction can be determined directly without calibration, but corrections for heat exchange between the calorimeter and the surroundings must be applied. For a large number of isoperibol... [Pg.314]

The observed temperature change of the calorimeter proper during the main period, 7> - 7j, is not exclusively determined by the amount of heat released in the bomb process. It is also due to the heat exchanged with the surroundings, the heat of stirring, and the heat dissipated by the temperature sensor. The observed temperature change must therefore be corrected for these contributions by an amount represented by A7COrr in equation 7.2 to obtain the adiabatic temperature rise ... [Pg.90]

A variation, which results in a more simple apparatus, is the drop calorimeter. The test piece is heated (or cooled) externally, dropped into the calorimeter and the resultant change in temperature monitored. For the simplest measurements, the calorimeter need not be surrounded by an adiabatic jacket but in that case, corrections for the heat exchange with the surroundings must be applied. A procedure using a drop calorimeter has been standardized for thermal insulation in ASTM C35l". It is possible to combine the adiabatic and drop calorimeter methods by dropping a heated sample into an adiabatic chamber and this has been used for plastics12. [Pg.277]

In fact, the simple detection device used in the laboratory was unable to detect the exothermal reaction At laboratory scale, the heat exchange area is larger by about two orders of magnitude (see Section 2.4.1.2), compared to plant scale. Hence the heat of reaction could be removed without detectable temperature difference, whereas at plant scale the same exotherm could not be mastered. This incident enhanced the necessity of a reaction calorimeter and promoted the development of the instrument, which was under development at this time by Regenass [1], Later, it became a commercial device (RC1). [Pg.81]

In this category of calorimeters, we find the isothermal calorimeters and the dynamic calorimeters where the temperature is scanned using a constant temperature scan rate. The instrument must be designed in such a way that any departure from the set temperature is avoided and the heat of reaction must flow to the heat exchange system where it can be measured. The instrument acts as a heat sink. In this family we find the reaction calorimeters, the Calvet calorimeters [7], and the Differential scanning calorimeter (DSC) [8],... [Pg.85]

Another interesting application of micro reactors is to use them as calorimeters. They may show excellent performance in terms of sensitivity [9-12]. Moreover, their performance in terms of heat exchange allows study of the kinetics of fast exothermal reactions under isothermal conditions. Such a development was realized by Schneider [13, 14], who studied such a reaction with a power of up to 160 kW kg-1. This type of calorimeter is simple to use and determines the reaction kinetics in a short time, with very small amounts of reaction mass, and without any hazard for the operator. [Pg.201]

A 2.5 m3 stainless steel stirred tank reactor is to be used for a reaction with a batch volume of 2 m3 performed at 65 °C. The heat transfer coefficient of the reaction mass is determined in a reaction calorimeter by the Wilson plot as y = 1600Wnr2KA The reactor is equipped with an anchor stirrer operated at 45 rpm. Water, used as a coolant, enters the jacket at 13 °C. With a contents volume of 2 m3, the heat exchange area is 4.6 m2. The internal diameter of the reactor is 1.6 m. The stirrer diameter is 1.53 m. A cooling experiment was carried out in the temperature range around 70 °C, with the vessel containing 2000 kg water. The results are represented in Figure 9.16. [Pg.224]

In an ideal adiabatic calorimeter, there is no heat exchange between the calorimetric vessel and the surroundings. This implies that the temperature in the calorimetric vessel will increase (exothermic processes) or decrease (endothermic processes) during the measurement. The heat quantity, evolved or absorbed during an experiment, is in the ideal case equal to the product between the temperature change, AT, and the heat capacity of the calorimetric vessel (including its content), C ... [Pg.276]

The amount of heat can be measured in a device called a calorimeter. A calorimeter is a container with insulated walls. The insulation prevents a rapid heat exchange between the contents of the calorimeter and the surroundings. In the closed environment of the system, there is no loss or gain of heat. Since the change in temperature of the contents of the calorimeter is used to measure the magnitude of the heat flow, a thermometer is included with the calorimeter. [Pg.105]

Fig. 17. Schematic design of a heat flux calorimeter. Both the temperature in the reactor and in the circuit (or jacket) are measured as sensitively and reproducibly as possible. A well-tuned temperature controller keeps the reactor temperature constant by feeding the circuit with warmer or colder water or oil. The circulating water or oil can be taken from either a chilled and a heated reservoir or, as shown, be heated or cooled via external heat exchangers. Calibration is made possible via an electric heater of known power... Fig. 17. Schematic design of a heat flux calorimeter. Both the temperature in the reactor and in the circuit (or jacket) are measured as sensitively and reproducibly as possible. A well-tuned temperature controller keeps the reactor temperature constant by feeding the circuit with warmer or colder water or oil. The circulating water or oil can be taken from either a chilled and a heated reservoir or, as shown, be heated or cooled via external heat exchangers. Calibration is made possible via an electric heater of known power...
In the next Sample Problem, you will use what you have just learned to calculate the specific heat capacity of a metal. This problem is similar to the calculation of the specific heat capacity of canola oil in section 14.3. Here, however, a calorimeter is used to reduce the heat exchange to the environment. [Pg.604]

The temperature difference between the calorimetric vessel and the calorimeter cover read-off from the temperature versus time curve has to be corrected for the heat introduced by stirring as well as for the heat exchange between the calorimetric vessel and the cover. [Pg.233]

Calorimetry of non-reacting systems involves the measurement of heat capacity dependencies on temperature, which enables us to calculate the enthalpies of phase transformations. Based on the prevailing mode of the heat exchange between their individual parts, calorimeters for this purpose can be classified as low-, medium-, and high-temperature calorimeters. In the measurement of thermodynamic parameters of molten electrolytes, mostly the last two types of calorimeters are used. [Pg.238]


See other pages where Heat exchange calorimeters is mentioned: [Pg.309]    [Pg.274]    [Pg.389]    [Pg.309]    [Pg.274]    [Pg.389]    [Pg.1914]    [Pg.156]    [Pg.87]    [Pg.196]    [Pg.393]    [Pg.83]    [Pg.84]    [Pg.159]    [Pg.571]    [Pg.574]    [Pg.82]    [Pg.224]    [Pg.278]    [Pg.292]    [Pg.180]    [Pg.154]    [Pg.128]    [Pg.393]    [Pg.7]    [Pg.494]    [Pg.1247]    [Pg.1914]   