Generators classified areas

Apart from considerations given to corrosion resistance and suitability for hazardous (classified) areas, the selection of electric motors for oil field applications is the same as the selection of electric motors for other industrial applications. One exception may be the selection of motors for areas where electric power is self-generated. Frequency and voltage variations may occasionally occur at such locations. For such locations, consideration should be given to specifying motors which are tolerant to at least 10% voltage variations and 5% frequency variations. [Pg.542]

Space heaters, particularly in electrical motors and generators which may be idle for significant periods of time, can also help prevent the accumulation of moisture. Space heaters installed in classified areas must operate at temperatures below high temperature devices. [Pg.546]

Air intakes to heating and ventilation systems, air compressors for process, instrument and breathing air, and to prime movers for gas compressors, power generation and pumps should be located as far as practical from contamination by dust, toxic and flammable materials release sources. They should not be located in electrically classified areas. If close to possible vapor releases (as confirmed by dispersion analyses( they should be fitted with toxic or combustible gas detection devices to warn of possible air intakes hazards and snutdown and isolate the incoming air ductwork and fans. [Pg.100]

Where ventilation is installed to effect a reduction in the area electrical classification, the rate should be no less than 12 air changes per hour for an adequately ventilated area in accordance with API RP 500. Areas containing ignition sources, such as control and switchgear buildings, gas turbine acoustical enclosures, and power generators, should be pressurized in accordance with NFPA 496, if located in an electrically classified area. [Pg.163]

To minimize the risk of fire, explosion, or release of hazardous wastes that may contaminate the environment, an industrial plant classified as a generator is required to have the following on site, and immediately accessible to its hazardous waste handling area ... [Pg.105]

Galai Dynamic Shape Analyzer DSA-10 is a complete shape characterization system for particles in motion. All particles are classified by maximum and minimum diameters, area and perimeter, aspect ratio, shape factor and more. A video microscope camera synchronized with a strobe light takes still pictures continuously of particles in dynamic flow, generating shape information on tens of thousands of particles, in the 1 to 6,000 pm range in minutes. [Pg.477]


See other pages where Generators classified areas is mentioned: [Pg.461]    [Pg.157]    [Pg.27]    [Pg.373]    [Pg.125]    [Pg.89]    [Pg.20]    [Pg.17]    [Pg.223]    [Pg.643]    [Pg.367]    [Pg.263]    [Pg.276]    [Pg.4]    [Pg.408]    [Pg.302]    [Pg.218]    [Pg.2]    [Pg.150]    [Pg.3]    [Pg.190]    [Pg.297]    [Pg.168]    [Pg.131]    [Pg.45]    [Pg.289]    [Pg.19]    [Pg.368]    [Pg.425]    [Pg.131]    [Pg.88]    [Pg.268]    [Pg.61]    [Pg.373]    [Pg.17]    [Pg.555]    [Pg.379]    [Pg.408]    [Pg.17]    [Pg.102]    [Pg.490]    [Pg.406]    [Pg.378]    [Pg.406]   