Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Generator column, cross section

In its most common form, a trajectory model moves a vertical column, with a square cross section intersecting the ground, at the mean wind speed, with pollutants added to the bottom of the column as they are generated by each location over which the column passes. Treatment of vertical dispersion varies among models, from those which assume immediate vertical mixing throughout the column to those which assume vertical dispersion using a vertical coefficient with a suitable profile (15). [Pg.326]

Ideally, the sample should be injected onto the column as an infinitely thin disc, which covers the total cross section of the column. Because this is impossible, PSS has injected finite volumes onto the columns. In theory, these injection volumes should be as low as possible. In order to be able to detect the sample with significance, a certain (high) concentration of the sample has to be injected. This concept works well for low molar mass compounds, which do not generate much sample viscosity. However, when working with samples... [Pg.282]

Frmdamentally, air-lift bioreactors are a modification of the bubble colunms that generate air-flow for medium circulation unidirectionally by having at least two columns—a raiser column and a downer column. They are either a draft tube or an external loop bioreactor. The bubbles sparged into a draft tube generate upward flow and medium pours into the annular space between the draft tube and bioreactor vessel and flows downwards. An essential design feature to consider is the bioreactor ratio of the height (H) to the diameter (D). Values of H/D of five or more are needed for sufficient mixing (18). Efficiency of medium circulation depends on the rate of aeration and on the ratio of the cross-sectional area of the draft tube to the total... [Pg.144]

Figure 13-10 a Cross section of a radionuclide generator for the production of techne-tium-99m (Tc-99m) by sterile 0.9% sodium chloride elution of a sterile alumina (AI Os) column that has molybdenum-99 (Mo-99) adsorbed on it. (Courtesy of Dupont-Pharma, Billerica, MA.)... [Pg.462]

Pneumatic amplifier pumps are used for column packing and for applications where a pressure of over 500 bar is needed. With this design, a relatively low gas pressure activates the larger cross-sectional area of a piston which at its other end is in contact with the eluent over a much smaller area. The force is the same on both sides of the piston but the pressure is higher on the smaller area, according to the ratio of the two areas. The pressure amplification can be as high as 70-fold this means that a gas pressure of 10 bar can generate an eluent pressure of 700 bar. [Pg.64]

When the solid phase is fixed (e.g., as a capillary, membrane, or porous plug), an electric field induces a flow of liquid termed electro-osmosis. The character of the flow depends on the construction of the apparatus. For example, in an electrophoretic cell, the liquid flows in one direction near the walls and in the opposite direction in the center of the cell, and the net flow across the cell cross-section is zero (Figure 2.2). Electro-osmosis can also be demonstrated as a difference in pressure (height of a water column) generated as a result of an electric field applied to a capillary, membrane, or porous plug. [Pg.46]

Fig. 12 (a) Cross-sectional view of a microchip, heating element, and thermocouples, (b) Diagram of the microchip used for on-chip proteolytic reactions, separations, and post-column labeling for generating fluorescent moieties. The fluid reservoirs are (1) substrate, (2) enzyme, (i) buffer, (4) sample waste, (5) NDA, and (6) waste. Reproduced from [134]... [Pg.284]

DCIM-MS has been coupled to liquid chromatography (LC) for analyzing complex peptide samples [36], Peptides eluting from the LC column were analyzed on an IMS-Q-TOF mass spectrometer. The ions generated from the source were accumulated in an ion trap and injected periodically into the drift tube. After mass analysis by the quadrupole, ions were subjected to collision-induced dissociation (CID) within an octopole collision cell and the product ions were analyzed by a TOF analyzer. Using this instrumental configuration, the urinary proteome [37], the Drosophila melano-gaster head proteome [38], and the human plasma proteome [39] have been analyzed. While many additional measurements, compared to standard mass spectrometry-based proteomics experiments, were obtained (for example, collision cross-sections), these were not used to improve upon protein identification results. [Pg.208]


See other pages where Generator column, cross section is mentioned: [Pg.1814]    [Pg.403]    [Pg.279]    [Pg.371]    [Pg.319]    [Pg.14]    [Pg.260]    [Pg.42]    [Pg.162]    [Pg.61]    [Pg.138]    [Pg.749]    [Pg.509]    [Pg.180]    [Pg.609]    [Pg.393]    [Pg.1574]    [Pg.148]    [Pg.55]    [Pg.489]    [Pg.264]    [Pg.552]    [Pg.152]    [Pg.279]    [Pg.238]    [Pg.1818]    [Pg.219]    [Pg.185]    [Pg.414]    [Pg.417]    [Pg.1070]    [Pg.397]    [Pg.28]    [Pg.334]    [Pg.57]    [Pg.291]    [Pg.317]    [Pg.163]    [Pg.669]    [Pg.489]    [Pg.287]    [Pg.44]   
See also in sourсe #XX -- [ Pg.13 ]




SEARCH



Column cross-section

© 2024 chempedia.info