Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Framing supports

Fig. 39) lay the tube on a small wire frame on the left-hand pan of the balance. The frame supports the tube at two points. Then put on the counterpoise (always use the same weights as counter-... [Pg.63]

Fig. 14. (a) Photograph of the frame supporting the shield/resonator and sample holder ... [Pg.127]

African oil palm nuts, which are less thick-shelled than most American palm nuts, are hand cracked to some extent but in Indonesia and Malaysia they are usually machine cracked. In one type of cracking machine, the nuts are fed to the center of a rotor equipped with curved baffles, along which the nuts are flung out against a heavy steel housing and broken by impact. Another type of machine resembles a hammer mill. The rotor consists of a frame supporting four heavy steel paddles the nuts are dropped into the path of the paddles and cracked by impact. [Pg.2517]

Onr next engraving illustrates a form of strainer which is used when bulky precipitates are required to be filtered, washed and drained. Ferric hydroxide is precipitated in large quantities for tho manufacture of the scale preparations of iron, and it is conveniently separated and washed on a piece of strong calico stretchewooden frame supported on short wooden legs. In this case It should be noted that the precipitate is wanted the filtrate is allowed to run to waste. [Pg.387]

Electrolytic dissolution in nitric acid has been used at the Savannah River [B22] and Idaho Qiemical Processing plants [AlO, All] to dissolve a wide variety of fuels and cladding materials, including uranium alloys, stainless steel, aluminum, zircaloy, and nichrome. The electrolytic dissolver developed by du Pont [B22], pictured in Fig. 10.4, uses niobium anodes and cathodes, with the former coated with 0.25 mm of platinum to prevent anodic corrosion. Metallic fuel to be dissolved is held in an alundum insulating frame supported by a niobium basket placed between anode and cathode and electrically insulated from them. Fuel surfaces facing the cathode undergo anodic dissolution in a reaction such as... [Pg.471]

It consists of two bronxe side frames supporting four nairs of bronxe toothed rollers plarril on different levels and nar-ing their axes parallel and liorlxontil. [Pg.160]

Figure 3.8 shows one type of completely demountable cell for liquids. The parts are laid out in order of assembly as follows cell frame, supporting gasket, window spacer(s), window with holes, gasket, metal plate with holes for syringes and Teflon stoppers, O rings, and the screw-on cover for tightening the cell. [Pg.52]

Figure 4 Overall bending test frame supporting the panel. Figure 4 Overall bending test frame supporting the panel.
The DeNora cells [68,72] have cathode areas ranging from 4.5 to 36 m, operating at 10-11 kA m . These cells are covered with a flexible, multilayer sheet of an elastomer, which is supported by the anode rods. DSA anodes, with four stems per anode, are suspended in frames supported from the cells. [Pg.400]

The older filters consisted of a timber frame supporting a cloth placed above a suitable storage tank. This method was extremely slow and nowadays the application of pressure across the filter cloth is usually employed to speed up the operation. Plate and frame filters (Fig. 3.6) which employ this principle are usually constructed of timber, cast iron, or rubber-covered steel. The plates and frames have the same outside shape, the plates support the filter cloth against a ribbed surface and the frames accumulate the solids. The number of plates and frames used may be varied, and their order of assembly is often indicated by markings stamped on the outer edges. The slurry is fed into the press by a pump and when the specified pressure is... [Pg.46]

All vessels were fitted with external wall thermocouples (3 mm, stainless steel, sheathed type K). Interior fluid temperatures, vapor and liquid, were measured on several levels at a single, near-eentral, vertieal position eorresponding to the fill-level gauge connection with similar, though 1.5-mm diameter, thermocouples. Both vapor and liquid pressures were determined from remote ealibrated pressure transducers. The target tank was mounted on a frame supported on four fire-proteeted load cells these were used to determine the variation in propane mass with PRV aetion. [Pg.474]

The first known plastic-bodied car was conceived by Henry Ford I as the soybean car . A prototype was produced in 1941, with a tubular steel frame supporting 14 phenolic panels (derived in fact from petroleum, and not soya bean oil). Costs turned out to be far higher than anticipated (the panels were described as only a quarter of an inch thick ). The car is best remembered now for the famous photograph of it resisting a sledgehammer vigorously wielded by Henry Ford (see Fig. 5.1). The Scarab of 1945 was a... [Pg.93]

Consider a rigid frame supporting a liquid membrane. A flexible loop, secured by two threads to the frame, is embedded in the membrane (Figure 1.4). The loop is free to take on any shape until the membrane is punctured, at which time the loop stretches into a circle. [Pg.4]

AIF.l. Fundamental Frequency of Tower Structures AIF.2. For Cooling Tower Shell Shapes Analysis AIF.3. A Steel Frame Supporting a Rotating Machines... [Pg.757]

Steel Frame Supporting a Rotating Machinery Problem Example... [Pg.769]

A frame supporting a rotating machinery in a nuclear laboratory exerts a typical horizontal force F(t) at the girder level as shown in Fig. AIF.3. In a normal practice the value oi F(t) F(t) = 200 sin (5.3)t KN) evaluation dynamic shear and bending moment an essentially demanded. [Pg.769]

The Uhde cells (Fig. 22, also see Fig. 25) are available with a cathode surface area 4-30 m for chlorine production rates 10-1000 t/d for the complete cell installation. The brine flows in via an inlet box fitted with two pipes for the removal of chlorine. The weak brine is removed at the end of the cell. The solid cover is fixed to the side walls by clamps. The anodes are suspended in groups in carrying frames supported near the cells on transverse girders with lifting gear. The anode rods are raised and lowered... [Pg.37]

Problem frames support developers in analyzing problems to be solved. They show what domains have to be considered, and what knowledge must be described and reasoned about when analyzing the problem in depth. Other problem frames besides the commanded behavior frame are required behaviour, simple workpieces, information display, and transformation. [Pg.313]

Longitudinal Strain (Uniaxial Strain) Frame supports the stretched specimen Static stretch applied... [Pg.292]

Figure 12.8 External frame-supported end closures (a) frame design of several plates (b) frame prestressed by tie rods (c) frame prestressed by wire winding (d) appropriate vessel with covers. Figure 12.8 External frame-supported end closures (a) frame design of several plates (b) frame prestressed by tie rods (c) frame prestressed by wire winding (d) appropriate vessel with covers.
Where quick opening is less important than fatigue life, the internal thread closure can also be used with a continuous thread (see Figure 12.5a). Also, frame-supported end closures (Figure 12.8) can be operated quickly, although the manipulation of heavy parts is required (vessel or frame). [Pg.298]


See other pages where Framing supports is mentioned: [Pg.316]    [Pg.1850]    [Pg.903]    [Pg.213]    [Pg.209]    [Pg.1122]    [Pg.337]    [Pg.316]    [Pg.452]    [Pg.1609]    [Pg.31]    [Pg.1854]    [Pg.168]    [Pg.303]    [Pg.547]    [Pg.783]    [Pg.230]    [Pg.428]    [Pg.570]    [Pg.392]    [Pg.459]    [Pg.478]    [Pg.80]    [Pg.619]    [Pg.772]    [Pg.55]    [Pg.325]    [Pg.168]   
See also in sourсe #XX -- [ Pg.264 ]




SEARCH



© 2024 chempedia.info