Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Foreign matter

Lubricating oil used in intermittent service must show the least possible variation in viscosity with respect to temperature and must be changed at frequent intervals to remove the foreign matter collected during service. The stabiUty of such oil is therefore of less importance than the stabiUty of oil used in continuous service for prolonged periods without renewal. Lubricating oil for continuous service must be extremely stable because the engines in which it is used operate at fairly constant temperature without frequent shutdown. [Pg.211]

The perforated pipe distributor comprises a central feed sump and pipes that branch out from the sump to provide the liquid discharge. The level in the sump varies with liquid total flow rate, and the size of the lateral pipes and their perforations must be determined carefully to ensure that the ends of the pipes are not starved for hquid. The orifices are typically 4 to 6 mm diameter, and can be subject to phigging if foreign matter is present. The pipes must be leveled carefully, especially for large diameter columns. [Pg.1396]

The process is then resumed. Meanwhile, regeneration is occurring by a similar flow system in the regeneration tank, from which the regenerated ion exchanger is transferred periodically to the hopper above the water-rinse tank. In the latter, the resin particles are fluidized to flush away fines and accumulated foreign matter before the resin is returned to the adsorption tank. [Pg.1557]

Tr ash removal—Removal of extraneous foreign matter from a processed material. Essentially a form of scalping operation. Type of screen employed will depend on size range of processed material—coarse, fine, or ultrafine. [Pg.1771]

To protect the surface from contamination by foreign matter, it should not be touched, welted or subject to condensation. [Pg.404]

Check whether float is stuck with dirt or foreign matter. [Pg.329]

The celluloid dough is then filtered by forcing through a pad of calico and brass gauze backed by a heavy brass plate at a press of about 1.5 tons per square inch. Any undesirable foreign matter is thus separated from the dough. [Pg.618]

From penetration of unbroken skin, or cuts. Foreign matter, e.g. grease, metal, concrete, may also be injected into subcutaneous tissues. [Pg.275]

Air pollution The presence of foreign matter (gaseous or particulate or combinations of both), bacteria, sound, or other undesirable elements in air, which is detrimental to the health or welfare of man, animals, plants, or materials. [Pg.1410]

Foreign matter in pumped fluid chewed up seal... [Pg.13]

The periodic or critical load inspection in the field should be conducted by the crew with the inspector. For the periodic or critical load inspection, all foreign matter should be removed from surfaces inspected. Total field disassembly is generally not practical, and is not recommended, except as may be indicated in the detailed procedure for each tool. [Pg.543]

To prevent foreign matter from damaging components and choking valves or atomizer orifices, filters must be incorporated into the handling system. There are usually two stages of filtration. The first provides protection for pumps and fire valves which handle oil at temperatures below those required at the oil-burning equipment. Second-stage... [Pg.255]

Heat generated by the compressor and prime mover must be dispersed. For air-cooled units sited in enclosed rooms this heat must be removed in order to limit the temperature rise. It is sometimes possible to recover this heat for use elsewhere. Intake openings should be located so that dust and other foreign matter do not enter with the air. [Pg.547]

Many systems are idle for long periods after operating at high temperatures. This permits moisture to condense in the system, resulting in rust formation. Certain corrosion-and rust-preventive additives are added to hydraulic liquids. Some of these additives are effective only for a limited period. Therefore, the best procedure is to use the liquid specified for the system for the time specified by the system manufacturer and to protect the liquid and the system as much as possible from contamination by foreign matter, from abnormal temperatures, and from misuse. [Pg.602]


See other pages where Foreign matter is mentioned: [Pg.146]    [Pg.359]    [Pg.486]    [Pg.10]    [Pg.44]    [Pg.46]    [Pg.264]    [Pg.345]    [Pg.129]    [Pg.129]    [Pg.498]    [Pg.255]    [Pg.257]    [Pg.298]    [Pg.438]    [Pg.293]    [Pg.152]    [Pg.91]    [Pg.230]    [Pg.384]    [Pg.387]    [Pg.388]    [Pg.309]    [Pg.309]    [Pg.526]    [Pg.526]    [Pg.536]    [Pg.537]    [Pg.1233]    [Pg.1973]    [Pg.224]    [Pg.239]    [Pg.22]    [Pg.314]    [Pg.164]    [Pg.1272]    [Pg.584]   