Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Flow cells, types

Economic Aspects. Costs for gc/k/ms instmments vary widely depending on the sophistication of the components. At the lower end of the scale is the flow cell type gc/ftks connected to a benchtop mass spectrometer. These are available for about 115,000—150,000. The isolation type gc/fdr can also be interfaced with a benchtop mass spectrometer. The prices range from about 200,000—300,000. [Pg.402]

If a nonstandard flow cell snch as a semi-micro flow cell with a shorter path length is nsed, a label on the outside of the detector signifying the flow cell type and path length is recommended. [Pg.261]

Table 4.1. Comparison of the performance of a probe-type and a flow-cell type sensor for fluoride... Table 4.1. Comparison of the performance of a probe-type and a flow-cell type sensor for fluoride...
Parameter Probe-type sensor Flow-cell type sensor... [Pg.218]

Fig. 54. Modified flow-cell type hydride generator. (Reprinted with permission from Ref. [155].)... Fig. 54. Modified flow-cell type hydride generator. (Reprinted with permission from Ref. [155].)...
Relevant parameters such as the characteristics of the flow cell, type of detector and data acquisition and treatment are briefly presented here. For a further discussion of developments in instrumentation related to the detection unit, overview articles [81—83] are recommended. [Pg.231]

Instrumental Interface. Gc/fdr instmmentation has developed around two different types of interfacing. The most common is the on-the-fly or flow cell interface in which gc effluent is dkected into a gold-coated cell or light pipe where the sample is subjected to infrared radiation (see Infrared and raman spectroscopy). Infrared transparent windows, usually made of potassium bromide, are fastened to the ends of the flow cell and the radiation is then dkected to a detector having a very fast response-time. In this light pipe type of interface, infrared spectra are generated by ratioing reference scans obtained when only carrier gas is in the cell to sample scans when a gc peak appears. [Pg.402]

In some systems, known as continuous-flow analy2ers, the reaction develops as the sample —reagent mixture flows through a conduit held at constant temperature. In such systems, the reaction cuvettes are replaced by optical reading stations called flow cells. In most analy2ers, whether of discrete- or continuous-flow type, deterrnination of electrolyte tests, eg, sodium and potassium levels, is done by a separate unit using the technique of ion-selective electrodes (ISE) rather than optical detection. [Pg.392]

Because the cells can intermpt the optical path in random orientations, individual scattering intensities are not proportional to cell volume. However, because thousands of cells of each type pass through the flow cell, the effects of orientation can be averaged To a first approximation HCT and platelet crit (PCT), the percentage of blood sample volume occupied by platelets, is proportional to the sums of the scattering intensities of the ted cells and platelets, respectively. MCV can be computed from HCT and RBC, whereas MPV can be computed from PCT and PLT. The accuracy of MCV deterrnined by this method is tied to the RBC accuracy, as is the case for the manual MCV method. Ortho Instmments Corporation s ELT-8 uses these counting and sizing methods. [Pg.403]

The vascular endothelium plays an important role in regulation of vascular tone and permeability. Dilatation of arterioles to increase blood flow and constriction of endothelial cells of postcapillary venules causing exsudation of plasma constituents illustrates the complex nature of this cell type. Moreover, by expression of adhesion molecules and secretion of chemokines endothelial cells play an important role in the recruitment of leukocytes to the inflamed area. Endothelial cells express two basic types of adhesion molecules on their surface ... [Pg.627]

Peter and Wang [266] invented a channel flow cell for rapid growth of CdTe films they showed that 2 p,m Aims can be deposited in less than 20 min, as opposed to the 2-3 h normally required in the conventional stirred single batch cells. The as-deposited films were structurally more disordered than the conventional ones, but after annealing and type conversion they became suitable for fabrication of efficient solar cells. A test cell with an AMI.5 efficiency approaching 6% was fabricated using a film prepared in the channel cell. [Pg.139]

It is well recognized that is an important regulatory element for many cellular processes, and that the major entry pathway for Ca in many cell types is via plasma membrane Ca channels. Ca channels are functional pores in membranes. They exist in plasma membranes, transverse tubule membranes and in intracellular membranes such as the sarcoplasmic and endoplasmic reticulum. Ca channels are normally closed when opened, Ca passively flows through the chan-... [Pg.315]

Reactor type Electrochemical micro flow cell Diaphragm material PTFE... [Pg.411]

The use of NMR for studying chemical reactions began about 30 years ago. In 1972, Asahi and Mizuta [11] reported a study of the performance of five different types of flow cells used in NMR studies of chemical reactions (a) a straight glass tube, (b) a pipette-type tube, (c) a spiral capillary in a conventional sample tube, (d) a jet in the base of a conventional tube, and (e) a conventional spinning tube with an inlet at the base and an outlet at a height of about 50 mm. The best results were... [Pg.127]

The basic mechanism for transition from bubble to slug flow appears to be the same as in vertical pipe flow. That is, as the gas flow rate is increased for a given liquid flow rate, the bubble density increases, many collisions occur and cell-type Taylor bubbles are formed, and the transition to slug flow takes place. As shown in the case of vertical pipe upflow, Taitel et al. (1980) assumed that this transition takes place when ac = 0.25. This criterion is also applicable here. However, because of the preferable geometry in the rod bundle, where the bubbles are observed to exist, instead of in the space between any two rods, this void fraction of 0.25 applies to the local preferable area only, a.L. The local voids, aL, can be related to the average void by (Venkateswararao et al., 1982)... [Pg.167]


See other pages where Flow cells, types is mentioned: [Pg.341]    [Pg.231]    [Pg.222]    [Pg.2650]    [Pg.3708]    [Pg.117]    [Pg.341]    [Pg.231]    [Pg.222]    [Pg.2650]    [Pg.3708]    [Pg.117]    [Pg.1910]    [Pg.402]    [Pg.404]    [Pg.404]    [Pg.405]    [Pg.405]    [Pg.180]    [Pg.1017]    [Pg.25]    [Pg.96]    [Pg.597]    [Pg.467]    [Pg.45]    [Pg.293]    [Pg.126]    [Pg.128]    [Pg.477]    [Pg.478]    [Pg.489]    [Pg.490]    [Pg.670]    [Pg.220]    [Pg.5]   
See also in sourсe #XX -- [ Pg.170 ]




SEARCH



Filterpress-type Flow Cells

Flow types

Flow-cell type hydride generator

© 2024 chempedia.info