Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fitting conductivity

In this equation, a is the conductivity, A is a constant proportional to the number of carrier ions, B is a constant, and To is the temperature at which the configurational entropy of the polymer becomes zero and is close to the glass transition temperature (Tg). The VTF equation fits conductivity rather well over a broad temperature range extending from Tg to about Tg +100 K. Equation [3.2] is an adaptation of the William-Landel-Ferry WLF relationship developed to explain the temperature dependence of such polymer properties as viscosity, dielectric relaxation time and magnetic relaxation rate. The fact that this equation can be applied to conductivity implies that, as with these other properties, ionic... [Pg.77]

Alternatively, a roll can be wound to fit a prismatic case as commonly found in lithium ion batteries. The roll is placed in a fitted conductive metal casing that has a Teflon or rubber gasket seal separating the outer can and top button contact. The cylindrical metal rod around which the film is wound becomes the internal contact. Contacts are ensured by soldering and then electrolyte is injected into the cell followed by a curable polymer sealant. The top of the casing is fitted with a vent, gasket layer, and top contact plate. To seal the device, the top of the can is mechanically crimped and the outer metal casing acts as the other contact and provides mechanical stability and rupture resistance. [Pg.212]

This substance, which exists in nature as a constituent of many plant oils and waxes, including the oil of raw wheat germ, is reputed to be important in physical fitness. Based on a long series of human experiments on physical fitness conducted by Dr. Thomas Kirk Cureton of the University of Illinois Physical Fitness Institute, it appears that octacosanol is one of the factors responsible for the beneficial effects of unrefined, unheated wheat germ oil. Vitamin E alone was not effective. [Pg.800]

Fig. 22 Normalized and fitted conductivity data and fitting curve vs. time (at 700°C - PO2 step from 0.01 atm to 0.21 atm). Fig. 22 Normalized and fitted conductivity data and fitting curve vs. time (at 700°C - PO2 step from 0.01 atm to 0.21 atm).
Figure C1.5.12.(A) Fluorescence decay of a single molecule of cresyl violet on an indium tin oxide (ITO) surface measured by time-correlated single photon counting. The solid line is tire fitted decay, a single exponential of 480 5 ps convolved witli tire instmment response function of 160 ps fwiim. The decay, which is considerably faster tlian tire natural fluorescence lifetime of cresyl violet, is due to electron transfer from tire excited cresyl violet (D ) to tire conduction band or energetically accessible surface electronic states of ITO. (B) Distribution of lifetimes for 40 different single molecules showing a broad distribution of electron transfer rates. Reprinted witli pennission from Lu andXie [1381. Copyright 1997 American Chemical Society. Figure C1.5.12.(A) Fluorescence decay of a single molecule of cresyl violet on an indium tin oxide (ITO) surface measured by time-correlated single photon counting. The solid line is tire fitted decay, a single exponential of 480 5 ps convolved witli tire instmment response function of 160 ps fwiim. The decay, which is considerably faster tlian tire natural fluorescence lifetime of cresyl violet, is due to electron transfer from tire excited cresyl violet (D ) to tire conduction band or energetically accessible surface electronic states of ITO. (B) Distribution of lifetimes for 40 different single molecules showing a broad distribution of electron transfer rates. Reprinted witli pennission from Lu andXie [1381. Copyright 1997 American Chemical Society.
Place 0 5 ml. of the pyridine in a 200 ml. round- or flat-bottomed flask and add 34 ml. (30 g.) of benzene. Fit the flask with a reflux water-condenser, and then place it in a cold water-bath. If the experiment is conducted in a fume-cupboard, the top of the condenser can be closed with a calcium chloride tube bent downwards (as in Fig. 61, p. 105 or in Fig. 23(A), p. 45, where the outlet-tube A will carry the calcium chloride tube) and the hydrogen bromide subsequently allowed to escape if, however, the experiment is performed in the open laboratory, fit to the top of the condenser (or to the outlet-tube A) a glass delivery-tube which leads through a piece of rubber tubing to an inverted glass funnel, the rim of which dips just below the surface of some water... [Pg.175]

The decomposition of the phosphorus oxybromide may also be conducted in a 1-litre three-necked flask charged with 400 g. of finely crushed ice and fitted with a reflux condenser and mechanical stirrer. [Pg.493]

Figure 2 illustrates the three-step MIBK process employed by Hibernia Scholven (83). This process is designed to permit the intermediate recovery of refined diacetone alcohol and mesityl oxide. In the first step acetone and dilute sodium hydroxide are fed continuously to a reactor at low temperature and with a reactor residence time of approximately one hour. The product is then stabilized with phosphoric acid and stripped of unreacted acetone to yield a cmde diacetone alcohol stream. More phosphoric acid is then added, and the diacetone alcohol dehydrated to mesityl oxide in a distillation column. Mesityl oxide is recovered overhead in this column and fed to a further distillation column where residual acetone is removed and recycled to yield a tails stream containing 98—99% mesityl oxide. The mesityl oxide is then hydrogenated to MIBK in a reactive distillation conducted at atmospheric pressure and 110°C. Simultaneous hydrogenation and rectification are achieved in a column fitted with a palladium catalyst bed, and yields of mesityl oxide to MIBK exceeding 96% are obtained. [Pg.491]

Many of these techniques involve source reduction— the preferred option on the EPA s hierarchy of waste management (24). Others deal with on-and off-site recycling. The best way to determine how these general approaches can fit a particular company s needs is to conduct a waste minimization... [Pg.225]

The changes in the optical absorption spectra of conducting polymers can be monitored using optoelectrochemical techniques. The optical spectmm of a thin polymer film, mounted on a transparent electrode, such as indium tin oxide (ITO) coated glass, is recorded. The cell is fitted with a counter and reference electrode so that the potential at the polymer-coated electrode can be controlled electrochemically. The absorption spectmm is recorded as a function of electrode potential, and the evolution of the polymer s band stmcture can be observed as it changes from insulating to conducting (11). [Pg.41]

Fig. 3. The lattice-matched double heterostmcture, where the waves shown in the conduction band and the valence band are wave functions, L (Ar), representing probabiUty density distributions of carriers confined by the barriers. The chemical bonds, shown as short horizontal stripes at the AlAs—GaAs interfaces, match up almost perfectly. The wave functions, sandwiched in by the 2.2 eV potential barrier of AlAs, never see the defective bonds of an external surface. When the GaAs layer is made so narrow that a single wave barely fits into the allotted space, the potential well is called a quantum well. Fig. 3. The lattice-matched double heterostmcture, where the waves shown in the conduction band and the valence band are wave functions, L (Ar), representing probabiUty density distributions of carriers confined by the barriers. The chemical bonds, shown as short horizontal stripes at the AlAs—GaAs interfaces, match up almost perfectly. The wave functions, sandwiched in by the 2.2 eV potential barrier of AlAs, never see the defective bonds of an external surface. When the GaAs layer is made so narrow that a single wave barely fits into the allotted space, the potential well is called a quantum well.
Experimental data that are most easily obtained are of (C, t), (p, t), (/ t), or (C, T, t). Values of the rate are obtainable directly from measurements on a continuous stirred tank reactor (CSTR), or they may be obtained from (C, t) data by numerical means, usually by first curve fitting and then differentiating. When other properties are measured to follow the course of reaction—say, conductivity—those measurements are best converted to concentrations before kinetic analysis is started. [Pg.688]


See other pages where Fitting conductivity is mentioned: [Pg.295]    [Pg.295]    [Pg.272]    [Pg.144]    [Pg.327]    [Pg.223]    [Pg.220]    [Pg.214]    [Pg.295]    [Pg.295]    [Pg.272]    [Pg.144]    [Pg.327]    [Pg.223]    [Pg.220]    [Pg.214]    [Pg.1982]    [Pg.2205]    [Pg.2966]    [Pg.440]    [Pg.476]    [Pg.185]    [Pg.565]    [Pg.792]    [Pg.880]    [Pg.155]    [Pg.135]    [Pg.167]    [Pg.18]    [Pg.460]    [Pg.266]    [Pg.306]    [Pg.176]    [Pg.290]    [Pg.586]    [Pg.333]    [Pg.336]    [Pg.253]    [Pg.319]    [Pg.504]    [Pg.2135]    [Pg.119]    [Pg.296]    [Pg.432]   
See also in sourсe #XX -- [ Pg.144 , Pg.145 , Pg.146 , Pg.147 ]




SEARCH



Profile fitting conducting

© 2024 chempedia.info