The measurement and registration of electrical impulse currents or voltages require that the electrical circuits employed do not alter the temporal or amplitudinal shape of the impulse. As long as the duration of the impulse exceeds about 0.1 (is the measurement circuit can be considered as consisting of discrete elements (resistors, inductances, capacitors). For the measurement of shorter impulses, the circuit has to be treated as consisting of distributed elements. [Pg.89]

R and r are the radii of the outer and inner conductor, respectively refers to the insulating material. The velocity of propagation of the signal is given as [Pg.89]

A is the reflected signal amplitude, is the incident signal amplitude, and Zq and Zj are the impedances on both sides of this point. Such condition is generated when cables of different impedances are joined or when the input resistor of the amplifier does not match the impedance of the signal cable. Let us discuss the consequences of Equation 143 in somewhat more detail. A preamplifier is connected to the Y-amplifier of an oscilloscope. The signal coming from the preamplifier travels in a coaxial cable with an impedance of Zq = 50 Q The input resistor of the oscillo-scopic amplifier is Z = 1 Inserting these values into Equation 143 yields for [Pg.89]

Only in the case that the input resistor matches the impedance of the cable, we have [Pg.90]

In the measurement of short drift times, sometimes the condition that the rise time of cell and preamplifier be much smaller than t is not fulfilled. In such a case, the convolution of the excitation functions p(t) and the response function is calculated [Pg.90]


Because photochemical processes are very fast, special techniques are required to obtain rate measurements. One method is flash photolysis. The excitation is effected by a diort pulse of light in an apparatus designed to monitor very fast spectroscopic changes. The rate characteristics of the reactions following radiation can be determined from these spectroscopic changes. [Pg.747]

Challis and Long497 have used the fast flow technique described above (p. 217) to measure the equilibrium protonation of azulene in a range of aqueous perchloric acid media at 7.5 °C and hence the rates of the forward protonation and reverse deprotonation, the overall exchange rate being the sum of these. Some representat i ve values are given in Table 141. Coupled with data obtained at other temperatures... [Pg.220]

Many transition metal complexes have been considered as synzymes for superoxide anion dismutation and activity as SOD mimics. The stability and toxicity of any metal complex intended for pharmaceutical application is of paramount concern, and the complex must also be determined to be truly catalytic for superoxide ion dismutation. Because the catalytic activity of SOD1, for instance, is essentially diffusion-controlled with rates of 2 x 1 () M 1 s 1, fast analytic techniques must be used to directly measure the decay of superoxide anion in testing complexes as SOD mimics. One needs to distinguish between the uncatalyzed stoichiometric decay of the superoxide anion (second-order kinetic behavior) and true catalytic SOD dismutation (first-order behavior with [O ] [synzyme] and many turnovers of SOD mimic catalytic behavior). Indirect detection methods such as those in which a steady-state concentration of superoxide anion is generated from a xanthine/xanthine oxidase system will not measure catalytic synzyme behavior but instead will evaluate the potential SOD mimic as a stoichiometric superoxide scavenger. Two methodologies, stopped-flow kinetic analysis and pulse radiolysis, are fast methods that will measure SOD mimic catalytic behavior. These methods are briefly described in reference 11 and in Section 3.7.2 of Chapter 3. [Pg.270]

The fast-scan technique optimizes measurement throughput by analyzing many cells in parallel. [Pg.138]

To demonstrate the utility of optophoresis in the preclinical stages of drug discovery, we screened several cell lines for their response to three standard chemotherapy drugs flu-darabine, vincristine, and Gleevec (imatinib mesylate, Novartis Pharmaceuticals, Basel, Switzerland) (Figure 7.6). To perform these measurements with the fast-scan technique, cells were suspended in a 9-mm-diameter well in a sample holder. The bottom surface of... [Pg.141]

The kinetics of the reaction of bromine atoms with simple aliphatic aldehydes have been measured by the fast-flow technique with resonance fluorescence detection, and by laser flash photolysis. [Pg.29]

Figure 24.11 compares values of Trms measured at port 1 using the in situ measurement technique with values of CO concentrations measured at port 4 using the fast extractive-sampling technique. The minimum in CO concentration... [Pg.398]

Schaefer and Natusch have shown that for many synthetic high polymers in solution the NOE factors and relaxation times of carbon atoms in or near the main chains eire similcir (.2. In such cases the relative peak areas in the spectra obtained by the noise-decoupled and fast pulsing technique can be used as a good approximation for quantitative microstructure euialysis. However for our investigation of the polymerization of cyclic ethers we are frequently interested in the quantitative measurements of monomers and oligomers as well as the concentrations of the continuously growing polymeric species. Therefore, the assumption of Schaefer and Natusch is not applicable. [Pg.249]

Udgaonkar JB, Hess GP (1987) Chemical kinetic measurements of a mammalian acetylcholine receptor using a fast reaction technique. Proc Natl Acad Sci USA 84 8758-8762... [Pg.39]


See other pages where Fast measurement techniques is mentioned: [Pg.350]    [Pg.332]    [Pg.89]    [Pg.350]    [Pg.332]    [Pg.89]    [Pg.512]    [Pg.515]    [Pg.1169]    [Pg.387]    [Pg.397]    [Pg.4]    [Pg.68]    [Pg.391]    [Pg.186]    [Pg.313]    [Pg.410]    [Pg.85]    [Pg.123]    [Pg.398]    [Pg.409]    [Pg.441]    [Pg.97]    [Pg.418]    [Pg.136]    [Pg.137]    [Pg.152]    [Pg.401]    [Pg.143]    [Pg.6]    [Pg.40]    [Pg.24]    [Pg.648]    [Pg.133]    [Pg.6]    [Pg.19]    [Pg.56]    [Pg.71]    [Pg.253]    [Pg.277]    [Pg.297]    [Pg.6]   


SEARCH



Fast measurement

© 2024 chempedia.info