Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Extension cords

Extensional viscosity Extension cord External lubricant External plasticizers Exterol Exter press Exton... [Pg.388]

The name, number, and voltage of equipment controHed should be clearly marked on aH switch boxes, compensators, and starters. Pias and chains should be required on aH butterfly switches. Extension cords should be three-wire and limited to 8-m lengths. [Pg.98]

DuPont—Dow is the primary suppHer of these polymers. There is an estimated 18,000 t of these elastomers used per year. The main uses of CPE are in constmction, automotive, and electrical appHcations. These include power steering hose, electrical cords used in low voltage appHcations (extension cords, ignition wire), pond liners, and as a plastic modifier to improve impact modification. [Pg.233]

Indii iduals should immediately report any unsafe electrical conditions to prevent an accidental shock. Damaged or unauthorized extension cords must be taken out of service immediately. Indir iduals must shut off power at Uie breaker before disconnecting a damaged cord. To ensure Uiat someone else does... [Pg.191]

Damaged or unautliorized extension cords must be taken out of service inunediately. [Pg.200]

Dangling Cords. In another case, a temporary light duty extension cord was used to hook up a new piece of equipment with an adapter to by-pass the three-wire grounded outlet. A year later, the equipment was still there and so was the cord, now hanging from a hook in the ceiling. [Pg.137]

I found an old sixty-foot extension cord in my garage. I cut the female plug off one end and twisted the bare copper ends of the white and black wires together. This formed the short circuit I wanted. Simply, I knew that when the cord was energized, the short-circuited wires would produce an instantaneous heat source, setting off the deflagration. [Pg.16]

About 10 30 in the morning, April 20th, I wandered outside the plant and over to where I had stashed the plug-in. Before plugging in the extension cord I checked the circuit breaker in the block house to ensure it was in the OFF position. Then I plugged in the detonation cord and went back into the block house and shut the steel door tight. .. I wanted to make sure I did not blow up in the explosion. [Pg.16]

Fortunately, many kinks aren t that hard to untangle. A hundred-foot extension cord that you didn t take the trouble to wind up properly is something you can straighten out with a little diligence and a few expletives. But others are more abstract. In our fledgling program, for example, one problem was the many variations in performance scores on different tests, scheduled inconsistently and after varying amounts of practice. [Pg.69]

What is the current density in an extension cord used for a 100-W table lamp Assume that the copper conducting wire in the cord is 1 mm in diameter and the voltage is 110 V. Express your result in A/cm as well as in A/m (compare to the values in Table 12.1). [Pg.219]

Improper use of extension cords, check here 8 Overfusing, check here 9 ... [Pg.284]

One of the larger uses is for wire and cable insulation. The flame resistance makes this the material of choice for residential wiring, extension cords, and so on. Inexpensive garden hose represents another large-volume use. Sports balls can be produced by rotational molding of plastisols. The low fabrication cost allows such products to dominate the lower-price-range market.76-77... [Pg.715]

The General Electric lamp is connected by an extension cord to a General Electric Autotransformer (Model No. 9T64Y3518), a transformer especially designed for 100-watt Type H-4 mercury-vapor lamps. After the lamp has been suspended in a quartz tube (approximately 34 cm. long and 5.0 cm. i.d. and rounded and closed on one end), the assembly is ready to be inserted into the cooling bath for use in the irradiation step. [Pg.180]

When connecting an ESD strap to an extension cord, you must connect it... [Pg.50]

C. When connecting an ESD strap to an extension cord, you must connect it to the ground pin to ensure both your safety and the proper discharge of ESD. [Pg.53]

Only heavy duty, three-pronged timers should be used for the lights and the fans. Never use more than one light or fan on each timer to avoid overload One timer, one light one timer, one fan. Do not use extension cords unless they have their own built in circuit breakers. [Pg.19]

Only heavy duty extension cords which have their own internal circuit breaker... [Pg.77]


See other pages where Extension cords is mentioned: [Pg.322]    [Pg.443]    [Pg.444]    [Pg.190]    [Pg.191]    [Pg.191]    [Pg.1]    [Pg.68]    [Pg.16]    [Pg.352]    [Pg.322]    [Pg.154]    [Pg.127]    [Pg.419]    [Pg.83]    [Pg.486]    [Pg.500]    [Pg.191]    [Pg.191]    [Pg.991]    [Pg.352]    [Pg.190]    [Pg.191]    [Pg.191]    [Pg.341]    [Pg.37]    [Pg.13]    [Pg.49]   
See also in sourсe #XX -- [ Pg.35 ]




SEARCH



Cordes

Cords

© 2024 chempedia.info