The film pressure is defined as the difference between the surface tension of the pure fluid and that of the film-covered surface. While any method of surface tension measurement can be used, most of the methods of capillarity are, for one reason or another, ill-suited for work with film-covered surfaces with the principal exceptions of the Wilhelmy slide method (Section II-6) and the pendant drop experiment (Section II-7). Both approaches work very well with fluid films and are capable of measuring low values of pressure with similar precision of 0.01 dyn/cm. In addition, the film balance, considerably updated since Langmuir s design (see Section III-7) is a popular approach to measurement of V. [Pg.114]

In the Wilhelmy slide method, it seems best to partly immerse the slide and determine the change in height with constant upward pull or the change in pull at constant position of the slide. If the latter procedure is used, then [Pg.114]

This method suffers from two disadvantages. Since it measures 7 or changes in 7 rather than t directly, temperature drifts or adventitious impurities can alter 7 and be mistakenly attributed to changes in film pressure. Second, while ensuring that zero contact angle is seldom a problem in the case of pure liquids, it may be with film-covered surfaces as film material may adsorb on the slide. This problem can be a serious one roughening the plate may help, and some of the literature on techniques is summarized by Gaines [69]. On the other hand, the equipment for the Wilhelmy slide method is simple and inexpensive and can be just as accurate as the film balance described below. [Pg.114]

Neumann has adapted the pendant drop experiment (see Section II-7) to measure the surface pressure of insoluble monolayers [70]. By varying the droplet volume with a motor-driven syringe, they measure the surface pressure as a function of area in both expansion and compression. In tests with octadecanol monolayers, they found excellent agreement between axisymmetric drop shape analysis and a conventional film balance. Unlike the Wilhelmy plate and film balance, the pendant drop experiment can be readily adapted to studies in a pressure cell [70]. In studies of the rate dependence of the molecular area at collapse, Neumann and co-workers found more consistent and reproducible results with the actual area at collapse rather than that determined by conventional extrapolation to zero surface pressure [71]. The collapse pressure and shape of the pressure-area isotherm change with the compression rate [72]. [Pg.114]

Film pressure is often measured directly by means of a film balance. The principle of the method involves the direct measurement of the horizontal force on a float separating the film from clean solvent surface. The film balance has been considerably refined since the crude model used by Langmuir and in many [Pg.114]