Equilibrium sampling through membranes

Liu, J.-F., J.A. Jonsson, and P. Mayer. 2005. Equilibrium sampling through membranes of freely dissolved chlorophenols in water samples with hollow fiber supported liquid membrane. Anal. Chem. 77 4800M-809. ... [Pg.93]

Hollow fiber-based extraction can be used for the determination of freely dissolved phenols or total concentration of phenols in environmental water samples. Liu et al. [199] applied hollow fiber-based supported liquid membrane (SLM) coupled with HPLC to the determination of freely dissolved chlorophenols in water samples. In this equilibrium sampling through membranes, freely dissolved chlorophenols were successfully determined in model solutions of humic acids and at low-ppb levels in river and leachate waters. [Pg.429]

The ammonia electrode operates by the diffusion of dissolved ammonia from the sample through a highly gas-permeable membrane into an internal proprietary filling solution. Diffusion proceeds until a reversible equilibrium is established between the ammonia level of the sample and the level in the filling solution. Hydroxide ions are formed in the filling solution by the ammonia-water reaction... [Pg.128]

Gas-sensing electrodes. A gas-sensing electrode consists of a combination electrode that is normally used to detect a gas in its solution by immersion. The sensor contains the inner sensing element, usually a glass electrode or another ISE, and around this a layer of a 0.1 Af electrolyte, surrounded by a gas-permeable membrane. On immersion of the sensor this membrane contacts the solution of the gas which diffuses through it until an overall equilibrium is established, i.e., the partial pressure of the gas attains an equilibrium between sample solution and membrane and between membrane and sensor electrolyte. For a better understanding of the interaction between this electrolyte and the... [Pg.84]

Gas sensors usually incorporate a conventional ion-selective electrode surrounded by a thin film of an intermediate electrolyte solution and enclosed by a gas-permeable membrane. An internal reference electrode is usually included, so that the sensor represents a complete electrochemical cell. The gas (of interest) in the sample solution diffuses through the membrane and comes to equilibrium with the internal electrolyte solution. In the internal compartment, between the membrane and the ion-selective electrode, the gas undergoes a chemical reaction, consuming or forming an ion to be detected by the ion-selective electrode. (Protonation equilibria in conjunction with a pH electrode are most common.) Since the local activity of this ion is proportional to the amount of gas dissolved in the sample, the electrode response is directly related to the concentration of the gas in the sample. The response is usually linear over a range of typically four orders of magnitude the upper limit is determined by the concentration of the inner electrolyte solution. The permeable membrane is the key to the electrode s gas selectivity. Two types of polymeric material, microporous and homogeneous, are used to form the... [Pg.224]

The pH of MCM-41 was measured with ASTM D 3838. About l.Og of dry MCM-41 was added to 20 ml of distilled water, and the suspension was shaken overnight to reach equilibrium. Then the sample was filtered, and pH of the solution was measured. The surface functional groups of the samples were determined by Boehm s titration method [13]. In the case of acid value, about l.Og of the sample was added to 100 ml of O.IN NaOH solution and the mixture was shaken for 24 h. Then the solution was filtered through a membrane filter and titrated with 0. IN HCI. Likewise, the base value was determined by converse titration. [Pg.433]

In the equilibrium dialysis/ultrafiltration method for determining free testosterone in blood, a sample is first equilibrated with radioactive testosterone. Free steroid is then separated from bound steroid by filtration through an anisotropic, hydrophilic ultrafiitration membrane. The driving force for ultrafiltration is provided by centrifugation at 1000 to 2000 xg. Filtrate containing free steroid collects in the filtrate cup, whereas protein-bound steroid remains above the filter. Radioactivity in the filtrate is a measure of... [Pg.2129]


See other pages where Equilibrium sampling through membranes is mentioned: [Pg.83]    [Pg.89]    [Pg.357]    [Pg.364]    [Pg.388]    [Pg.395]    [Pg.83]    [Pg.89]    [Pg.357]    [Pg.364]    [Pg.388]    [Pg.395]    [Pg.338]    [Pg.485]    [Pg.188]    [Pg.6]    [Pg.241]    [Pg.136]    [Pg.241]    [Pg.206]    [Pg.133]    [Pg.169]    [Pg.123]    [Pg.129]    [Pg.205]    [Pg.270]    [Pg.145]    [Pg.153]    [Pg.241]    [Pg.153]    [Pg.333]    [Pg.191]    [Pg.33]    [Pg.237]    [Pg.995]    [Pg.1257]    [Pg.1066]    [Pg.222]    [Pg.137]    [Pg.1010]    [Pg.61]    [Pg.63]    [Pg.244]    [Pg.576]   
See also in sourсe #XX -- [ Pg.83 ]