Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Enclosed column systems

Entirely enclosed column systems have also been proposed to reduce contamination, personal errors, and contact of the packed sample with atmospheric oxygen (anoxic conditions), whereby undesired decomposition of reduced mineral phases and oxidation of reduced water constituents are prevented (Wisotzky and... [Pg.491]

The system shown in Fig. 7-2 may be formed from the one shown in Fig. 7-1 by returning the bottoms B2 from column 2 to column 1. The addition of the recycle mass transfer stream does not change the general form of the equations for the capital 0 method where the reflux ratios and boilup ratios are specified. The heat balance enclosing column 1 must be modified, however, in order to account for the recycle stream B2. The resulting expression for the enthalpy function r10 is... [Pg.261]

The entire assembly is enclosed in a highly insulated cold box to conserve energy. The columns must be made as compact as possible to minimize capital investment as well as reduce heat leak. Up to 150 distillation trays are used in a double column system and tray spacings are kept small at 10 to 20 cm. The trays are typically multipass sieve trays with small diameter perforations. Because the distillation is an extremely clean service, perforations are typically as small as 1 mm. Many tray geometries are used, including multipass cross-flow, split cross-flow (parallel) and circular flow (race track) trays. Each has certain attributes which are used to optimize the column design for different design conditions. [Pg.11]

Figure 3. Detail of post column reaction system. Dashed line indicates components enclosed within model URS 051 reaction system. Figure 3. Detail of post column reaction system. Dashed line indicates components enclosed within model URS 051 reaction system.
One way that these operation regions can be identified to achieve optimization of the performance and productivity is through the use of contour plots derived directly from the experimental data for a particular polypeptide- or protein-ligate system as illustrated in Fig. 38. In this case, the optimization was based on a primary requirement of 94% yield. If a 60% column capacity utilization was the preferred option, the separation would have to be carried out in the region enclosed by the 94% yield curve and to the left of the 60% capacity curve. It can be seen that the highest production rate in the region occurs at the intersection of these two curves. Similar operational boundaries can be determined for the other cases, such as 70 or 50% as the preferred column capacities, and the values of fluid velocity and... [Pg.204]

In the columns identifying the experimental method, MW stands for any method studying the pure rotational spectrum of a molecule except for rotational Raman spectroscopy marked by the rot. Raman entry. FUR stands for Fourier transform infhired spectroscopy, IR laser for any infiured laser system (diode laser, difference frequency laser or other). LIF indicates laser induced fluorescence usually in the visible or ultraviolet region of the spectrum, joint marks a few selected cases where spectroscopic and diffraction data were used to determine the molecular structure. A method enclosed in parentheses means that the structure has been derived from data that were collected by this method in earlier publications. The type of structure determined is shown by the symbols identifying the various methods discussed in section II. V/ refers to determinations using the Kraitchman/Chutjian expressions or least squares methods fitting only isotopic differences of principal or planar moments (with or without first... [Pg.206]

Extensive experimental studies of simulated countercurrent gas-liquid chromatography have been dons.11 A system with 12 chromatography columns was enclosed in an oven. The system did not use a zone IV. Figure 14.3-51,1 shows one run for the separation of elhylcaprate from ethyl lauraie. The columns were packed with 15% OV-275 on chromosorb P and were operated at 160°C with nitrogen as tbe earner. This is a fairly difficult separation with a separation factor of 1.44. For a feed flow rate of 75 cm /h (Fig, ]4,3-5) the ethyl cap rate product was 94,2% pure and the ethyl laurate was 91.2% pure. When the feed flow rale was lowered to 25 crtrVh, the products were 99.4 and 99.3% pure, respectively. The results taken... [Pg.750]

The calculation procedures [the 0 method, Kb method, and constant composition method] developed in Chap. 2 for conventional distillation columns are applied to complex distillation columns in Sec. 3-1. For solving problems involving systems of columns interconnected by recycle streams, a variation of the theta method, called the capital 0 method of convergence is presented in Secs. 3-2 and 3-3. For the case where the terminal flow rates are specified, the capital 0 method is used to pick a set of corrected component-flow rates which satisfy the component-material balances enclosing each column and the specified values of the terminal rates simultaneously. For the case where other specifications are made in lieu of the terminal rates, sets of corrected terminal rates which satisfy the material and energy balances enclosing each column as well as the equilibrium relationships of the terminal streams are found by use of the capital 0 method of convergence as described in Chap. 7. [Pg.87]

For each total-flow rate of the set Du Bu D2, and B2 which may be fixed independently, there exists a capital 0 multiplier. If Dx is fixed, then D2 is seen to be dependent since it is uniquely determined by a total material balance which encloses the entire system. From the total material balances enclosing each column, it is seen that if Bt is fixed, then either Du D2, or B2 may be fixed... [Pg.102]

Limnocorral Study A limnocorral is an enclosed water column in a lake, pond, or marine environment that may or may not be in contact with the bottom sediments. Such a system has been used to study the effects of a wood preservative, tetrachlorophenol (Fig. 10.5). ° The water column (5 m x 5 m and 4.5 m deep) is enclosed by vinyl walls and a polyethylene liner was installed... [Pg.364]

Fig. 10. Pd EnCat microwave reactor columns, simple U-tube and enclosed system... Fig. 10. Pd EnCat microwave reactor columns, simple U-tube and enclosed system...
An HPLC instrument has at least the elements which are shown in Fig. 1.3 solvent reservoir, transfer line with frit, high-pressure pump, sample injection device, column, detector, and data recorder, usually together with data evaluation. Although the column is the most important part, it is usually the smallest one. For temperature-controlled separations it is enclosed in a thermostat. It is quite common to work with more than one solvent, thus a mixer and controller are needed. If the data acquisition is done by a computer it can also be used for the control of the whole system. [Pg.9]


See other pages where Enclosed column systems is mentioned: [Pg.541]    [Pg.541]    [Pg.33]    [Pg.101]    [Pg.569]    [Pg.94]    [Pg.22]    [Pg.310]    [Pg.81]    [Pg.411]    [Pg.154]    [Pg.1721]    [Pg.602]    [Pg.210]    [Pg.299]    [Pg.257]    [Pg.300]    [Pg.90]    [Pg.152]    [Pg.633]    [Pg.489]    [Pg.1967]    [Pg.81]    [Pg.71]    [Pg.214]    [Pg.287]    [Pg.204]    [Pg.562]    [Pg.325]    [Pg.174]    [Pg.62]    [Pg.775]    [Pg.328]    [Pg.1295]    [Pg.45]    [Pg.439]    [Pg.390]   
See also in sourсe #XX -- [ Pg.491 ]




SEARCH



Column system

Enclosed

© 2024 chempedia.info