In addition to conventional applications in conducting polymers and electrooptical devices, a number of recent novel applications have emerged. Switching of DNA electron transfer upon single-strand/double-strand hybridization fonns the basis for a new medical biosensor teclmology. Since the number of base pairs of length 20... [Pg.2974]

Emergency switch operation not understood or clear to the operator. Equipment works differently in different operating locations. [Pg.132]

Provide clear guidelines for operators when to use emergency switches... [Pg.132]

Emergency Switching. Operators need a way to transfer to the backup system if the computer fails. Preferably, this should be done with computer-set controllers equipped with remote switching connections so the transfer can be made without manual switching by the operators. [Pg.342]

Such work frequently has to be performed when sealing submerged pmnping stations. If a pumping station pumps fecal material, the concrete loses density and strength because of gas corrosion. In emergency switch-off of power, the pumps overflow with fecal matter. [Pg.361]

The most important measure in order to decrease fatality risk is Ae existence of a properly functioning emergency switch within reach (of operator) that will... [Pg.707]

The regulations identify four separate types of switching switching for isolation, switching for mechanical maintenance, emergency switching and functional switching. [Pg.184]

Emergency switching involves the rapid disconnection of the electrical supply by a single action to remove or prevent danger. [Pg.185]

The purpose of emergency switching is to cut off the electrical energy rapidly to remove an unexpected hazard. [Pg.185]

Emergency switching is for use by anyone. The device used for emergency switching must be immediately accessible and identifiable, and be capable of cutting off the full load current. [Pg.185]

The 3rd Amendment to the 17th Edition of the lET Regulations tells us at Note 5 of Table 53.4 that circuit protective devices and RCDs are not intended for frequent load switching. However, infrequent switching of MCBs is permissible for the purpose of isolation or emergency switching. [Pg.186]

System safety design with regard to maintenance, maintainability can the system be shut down easily and safely for maintenance work (N.B. emergency switches ) Is the system s maintainability good Does the design support easy and safe maintenance or add/increase the risks ... [Pg.34]

Following on from Recommendation 11, operators of Buncefield-type sites should evaluate the siting and/or suitable protection of emergency response facilities such as firefighting pumps, lagoons or manual emergency switches. ... [Pg.17]

Emergency standby protection (see also Chap. 5.12) may be provided by a single unit rated to protect a known segment of load that can be isolated with a two-way transfer (normal emergency) switch (Fig. 6.102).The size of this type of unit may range from 50 kW or under to approximately 1500 kW (Fig. 6.103). [Pg.1012]

The provision of emergency switching devices to ensure the supplies to the test area can be switched off quickly in an emergency. [Pg.318]